본문 바로가기
KERD
논문KCI 등재

다이옥신 숙련도 시험용 비산재 시료의 불확도 평가에 관한 연구

A Study on Uncertainty Estimation of Fly Ash for Dioxin Proficiency Testing

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Fly ash samples collected from municipal waste incinerator were prepared for proficiency testing of dioxin analysis. They were used to evaluate the homogeneity and stability through the several steps. Specially, one way ANOVA was used as analysis method in this study. In case of identified samples, measurement model equation of target isomer in analysis were formulated. Then uncertainties of results were calculated by selection of uncertainty cause and by calculation of uncertainty quantification, synthesis uncertainty, and expansion uncertainty. The portions of the uncertainties resulted from the amount of internal standard, the separation rate of sample, the relative reaction factor (RRF) of GC/MS, and efficiency of sample extraction were 35.6%,35.0%, 25.6%, 3.7%, respectively.

Abstract

Fly ash samples collected from municipal waste incinerator were prepared for proficiency testing of dioxin analysis. They were used to evaluate the homogeneity and stability through the several steps. Specially, one way ANOVA was used as analysis method in this study. In case of identified samples, measurement model equation of target isomer in analysis were formulated. Then uncertainties of results were calculated by selection of uncertainty cause and by calculation of uncertainty quantification, synthesis uncertainty, and expansion uncertainty. The portions of the uncertainties resulted from the amount of internal standard, the separation rate of sample, the relative reaction factor (RRF) of GC/MS, and efficiency of sample extraction were 35.6%,35.0%, 25.6%, 3.7%, respectively.

참고문헌 (14)

  1. Yoshio Iida, , BUNSEKI KAGAKU, 50(8), pp.571~576 (2001)
  2. BIPM, "측정불확도 표현지침 (GUM)", KRISS, IEC Guide 98-3, pp.2008, ~
  3. 한국교정시험인정기구, "숙련도시험 운영기준", ~ (2004)
  4. ISO Guide 35, "Reference materials-General and statistical principles for certification", ~ (2006)
  5. Xueli Cao, , Anal. Chem, 370, pp.1035~1040 (2001)
  6. R. Van Cleuvenbereen, , Chemosphere, 37, pp.2425~2438 (1998)
  7. EURACHEM, "CITAC", Quantifying Uncertainty in Analytical Measurement, 2000
  8. 문동호, "다이옥신 숙련도 시험용 시료의 제조", 한국환경분석학회지, 8(3), pp.143~153 (2005), 한국환경분석학회
  9. 국립환경과학원, "내분비계장애물질 측정분석방법", ~ (2002)
  10. T. Allen, "Particle Size Measurement", pp.300~305 (1997), Chapman
  11. EURACHEM Guide, "The Fitness for Purpose of Analytical Methods-A Laboratory Guide to Method Validation and Related Topics", ~ (1998)
  12. 전치혁, "공학응용통계", pp.135~155 (1998), POSTECH PRESS
  13. Joe M. Finkel, , Chemosphere, 19, pp.67~74 (1989)
  14. 최성운, , 대한안정경영과학회지, 9(6), pp.193~196 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (8건)