본문 바로가기
KERD
논문KCI 등재

CMB모델 적용을 위한 대기 미세먼지(PM_2.5) 중 원소분석방법에 관한 비교 연구

Comparative Study of Elemental Analysis Methods in the Atmospheric Fine Particulate Matter (PM_2.5) for the Application of CMB Receptor Model

0

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

This study was performed to compare the uncertainty of elemental analysis methods and the species of elements that can be analyzed using ICP (Inductively Coupled Plasma spectrometry), PIXE (Proton Induced Xray Emission), and XRF (X-Ray Fluorescence) for the PM_(2.5) (dp < 2.5 μm) filter samples. From this study, the XRF method has been proved to be the best way of elemental analysis for PM_(2.5). The XRF method has relatively detected very low uncertainty values compared to the PIXE except for Na and Mg. The number of elements measured above the limits of detection for ICP, PIXE, and XRF were 10, 12, and 23, respectively. Using the ICP method, Si, S, Zn, and Cu elements were not detected. In the case of PIXE method, the important indicator elements for the CMB (chemical mass balance) receptor model, such as Na, Mg, Cl, Cu, Br, and Ni, were not detected. However, all of these elements were detected using the XRF method.

Abstract

This study was performed to compare the uncertainty of elemental analysis methods and the species of elements that can be analyzed using ICP (Inductively Coupled Plasma spectrometry), PIXE (Proton Induced Xray Emission), and XRF (X-Ray Fluorescence) for the PM_(2.5) (dp < 2.5 μm) filter samples. From this study, the XRF method has been proved to be the best way of elemental analysis for PM_(2.5). The XRF method has relatively detected very low uncertainty values compared to the PIXE except for Na and Mg. The number of elements measured above the limits of detection for ICP, PIXE, and XRF were 10, 12, and 23, respectively. Using the ICP method, Si, S, Zn, and Cu elements were not detected. In the case of PIXE method, the important indicator elements for the CMB (chemical mass balance) receptor model, such as Na, Mg, Cl, Cu, Br, and Ni, were not detected. However, all of these elements were detected using the XRF method.

참고문헌 (9)

  1. K.L. Magliano, "Spatial and temporal variations in PM10 and PM2.5 source contributions and comparison to emissions during the 1995 integrated monitoring study", Atmos. Environ, 33, pp.4757~4773 (1999)
  2. 강병욱, "수용모델을 이용한 청주시 미세입자(PM2.5)의 기여도 추정", 한국대기환경학회지, 16(5), pp.477~485 (2000)
  3. J.J. Schauer, "Source apportionment of wintertime Gas-phase and particle-phase air pollutants using organic compounds as tracers", Environ. Sci. Technol, 34, pp.1821~1832 (2000)
  4. E. Vega, "Chemical composition of fugitive dust emitters in Mexico City", Atmos. Environ, 35, pp.4033~4039 (2001)
  5. 배민석, "Chemical composition and source apportionment of PM2.5 particles in the Sihwa area Korea", JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 51(3), pp.393~405, AIR & WASTE MANAGEMENT ASSOC
  6. 이학성, "수용모델을 이용한 서울지역 미세입자 (PM2.5)에 영향을미치는 배출원 특성에 관한 연구", 한국대기환경학회지, 21(3), pp.329~341 (2005), 한국대기환경학회
  7. T.J. Ward, "The 2003", 2004 Libby, Montana PM2.5 source apportionment research study, 2006, pp.40, 166~177
  8. J.C. Chow, "Measurement methods to determine compliance with ambient air quality standards for suspended particles", J. Air & Waste Manage. Assoc, 45, pp.320~382 (1995)
  9. X. Huang, "Emissions of trace elements from motor vehicles : potential marker elements and source composition profile", Atmos. Environ, 28(8), pp.1385~1391 (1994)

관련 논문AI추천

이 간행물의 다른 논문 (10건)