적외선양자폭포레이저와 차등흡광법을 이용한 대기 중 HONO와 H2O2의 동시 연속 측정 타당성 연구
Feasibility Study for Simultaneous Measurements of Atmospheric HONO and H 2 O 2 using a Tunable Infrared Quantum Cascade Laser Differential Absorption Spectrometer (QC-TILDAS)
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
We tested a tunable laser differential absorption spectrometer with two mid-infrared continuous-wave mode quantum cascade lasers (cw-QCLs) for simultaneous measurements of nitrous acid (HONO) and hydrogen per-oxide (H 2 O 2 ) in the remote marine atmosphere at Baengyeong Island, Korea in October 2012. Two lasers scanned frequencies that covered approximately 0.2 cm -1near at 1277.15 cm -1and 1283.3 cm -1for HONO and H 2 O 2 , respectively with resolution of about 0.001 cm -1per channel. Ambient air sample was drawn to a 260m multi-pass astigmatic sampling path cell at reduced pressure and light transmissions along predefined fre-quency ranges were detected at two peltier cooled HgCdTe detectors. The resulting one hour detection limits based on 2 s of background signal noise are 0.17 ppbv for HONO and 0.12 ppbv for H 2 O 2 . The concentrations over the measurement periods varied from below the detection limit to 0.8 ppbv for HONO, and from 0.5 ppbv to 0.8 ppbv for H 2 O 2 , respectively. Sensitivities and detection limits for QC-TILDAS of HONO and H 2 O 2 were acceptable for their continuous monitoring in the remote background air. However, we found that further improvement could be achieved by the stabilizing intensities of transmitted laser light sources and reducing the humidity interferences.
Abstract
We tested a tunable laser differential absorption spectrometer with two mid-infrared continuous-wave mode quantum cascade lasers (cw-QCLs) for simultaneous measurements of nitrous acid (HONO) and hydrogen per-oxide (H 2 O 2 ) in the remote marine atmosphere at Baengyeong Island, Korea in October 2012. Two lasers scanned frequencies that covered approximately 0.2 cm -1near at 1277.15 cm -1and 1283.3 cm -1for HONO and H 2 O 2 , respectively with resolution of about 0.001 cm -1per channel. Ambient air sample was drawn to a 260m multi-pass astigmatic sampling path cell at reduced pressure and light transmissions along predefined fre-quency ranges were detected at two peltier cooled HgCdTe detectors. The resulting one hour detection limits based on 2 s of background signal noise are 0.17 ppbv for HONO and 0.12 ppbv for H 2 O 2 . The concentrations over the measurement periods varied from below the detection limit to 0.8 ppbv for HONO, and from 0.5 ppbv to 0.8 ppbv for H 2 O 2 , respectively. Sensitivities and detection limits for QC-TILDAS of HONO and H 2 O 2 were acceptable for their continuous monitoring in the remote background air. However, we found that further improvement could be achieved by the stabilizing intensities of transmitted laser light sources and reducing the humidity interferences.
참고문헌 (17)
- B. Alicke, , Journal of Geophysical Research, 108, pp.1~17 (2003)
- M. Sorgel, , Atmospheric Chemistry and Physics, 11, pp.10433~10447 (2011)
- P. Mikuska, , Talanta, 77, pp.635~641 (2008)
- J. Stutz, , Atmospheric Environment, 44, pp.4090~4098 (2010)
- 김주애, "서울시 대기 중 과산화수소 농도 변화 특성", 한국대기환경학회지, 22(3), pp.297~307 (2006), 한국대기환경학회
- M. Lee, , Science of the Total Environment, 393, pp.299~308 (2008)
- 유재수, "The Proceedings of the Korean Institute of Electromagnetic", Engineering and Science, 20, pp.13~22 (2009)
- J. B. McManus, , Optical Engineering, 49, pp.111124~111111 (2010)
- L. Joly, , Laser Physics, 21, pp.805~812 (2011)
- B. H. Lee, , Applied Physics B, 102, pp.417~423 (2011)
- J. Mohn, , Atmospheric Measurement Techniques, 3, pp.609~618 (2010)
- 한일기, "GaAs", AlGaAs 3-Quantum Well 양자폭포레이저 (Quantum Cascade Lasers)에서 허용되는 에피정밀도를 위한 활성영역 모의실험, 2007, pp.16(4), 273~278[DOI]
- J. Faist, , Science, 264, pp.553~ (1994)
- 윤두협, , 전자통신동향분석, 21, pp.119~128 (2006)
- J. B. McManus, , Applied optics, 50, pp.74~85 (2011)
- K. Acker, , Atmospheric Environment, 40, pp.3123~3133 (2006)
- W. Hua, , Atmospheric Chemistry and Physics, 8, pp.6755~6773 (2008)