Tetraisopropylthiuram Disulfate을 Ionophore로 이용한카드뮴 이온 선택성 Poly(aniline) 고체 접촉 전극
Cadmium Ion Selective Poly(aniline) Solid Contact Electrode Based on Tetraisopropylthiuram Disulfate Ionophore
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The study conducted an experiment with copper ion SCEs, which used tetraisopropylthiuram disulfate as an ionophore, by changing the composition based on six plasticizers and lipotropy. The composition that showed the best response slope and response characteristic against copper ion was found when ionophore:PVC:o-NPOE:KTpClPB was 5.0:20.0:25.0:4.0. This composition had a response slope of 35.5 mV/decade within the range of 1.0×10-1.0~1.0×10-7.0M. In terms of the effect of interference ion, a minor interference was observed in zinc, while most of the other ions experienced relatively little interference. They showed consistent potentiometric responses, unaffected by pH fluctuations between 5.0 and 8.0, with 260 seconds of stabilization time and 18 seconds of response time. This indicates that it may be allowed to make practical use of such response characteristics when pH is in the above range. The standard deviation measured ten times each on 1.0×10-2.0M and 1.0×10-3.0M copper solutions was found to be 1.31 mV and 1.92 mV, respectively. The lifetime of electrode was about four months. They showed the exact response to cadmium ion disappearing in the measuring solution through EDTA titration.
Abstract
The study conducted an experiment with copper ion SCEs, which used tetraisopropylthiuram disulfate as an ionophore, by changing the composition based on six plasticizers and lipotropy. The composition that showed the best response slope and response characteristic against copper ion was found when ionophore:PVC:o-NPOE:KTpClPB was 5.0:20.0:25.0:4.0. This composition had a response slope of 35.5 mV/decade within the range of 1.0×10-1.0~1.0×10-7.0M. In terms of the effect of interference ion, a minor interference was observed in zinc, while most of the other ions experienced relatively little interference. They showed consistent potentiometric responses, unaffected by pH fluctuations between 5.0 and 8.0, with 260 seconds of stabilization time and 18 seconds of response time. This indicates that it may be allowed to make practical use of such response characteristics when pH is in the above range. The standard deviation measured ten times each on 1.0×10-2.0M and 1.0×10-3.0M copper solutions was found to be 1.31 mV and 1.92 mV, respectively. The lifetime of electrode was about four months. They showed the exact response to cadmium ion disappearing in the measuring solution through EDTA titration.
참고문헌 (19)
- L.J. Prodan, "The history of cadmium poisoning and the uses of cadmium", Journal of Industrial Hygiene and Toxicology, 14, pp.132~155 (1932)
- L. Friberg, "Cadmium in the Environment" (1974), CRC Press Cleveland in Ohio
- 김남송, "Cadmium에 의한 흰쥐의 간장 및 신장의 Metallothionein 변화와 방어 효과", 예방의학회지, 24(3), pp.287~304 (1991)
- 이광묵, "카드뮴 중독", 한국의 산업의학, 13, pp.16~19 (1974)
- K.E. Mason, "Effectiveness of selenium and zinc in protecting against cadmium induced injury of rat testis", Anatomical Record, 148, pp.304~309 (1964)
- 이용욱, "수질오염, 대기오염, 토양오염에 의한 식품오염", 국민영양, 10, pp.23~26 (1986)
- H. Kostial, "Cadmium", Trace Elements in Human and Animal Nutrition, 2, pp.319~345 (1986)
- F.W. Alexander, "Mineral and Trace-metal Balances in Children Receiving Normal and Synthetic Diets", An International Journal of Medicine, 43, pp.89~111 (1974)
- D. Dello, "Effects of micronutrients on metal toxicity", Arch Environ Health, 34, pp.30~33 (1979)
- J. Janata, "20 years of ion-selective field-effect transistors", Analyst, 119, pp.2275~2278 (1994)
- K.C. Gupta, "Cadmium Ion-Selective Electrode Based on Cyanocopolymer", Electroanalysis, 12(17), pp.1408~1413 (2000)
- A.C. Stevens, "Coated-wire cadmium ion-selective electrode based on the bidentate neutral carrier 4,4'-di(5-nonyl)-2,2'-bipyridine", Analytica Chimica Acta, 248(2), pp.315~321 (1991)
- as an electroactive material, "Water Science and Technology", 2010, 2510~2518
- A.K. Jain, "A new polystyrene based heterogenerous membrane of cerium(IV) vanadate as cadmium(II) ion selective electrode", Ind. Journal of Chemistry A, 33(12), pp.1122~1124 (1994)
- S.K. Sindhu, "Cadmium(II) ion selective electrode based on pyridine- 3-carboxyaldehyde thiosemicarbazone", Journal of the Indian Chemistry Society, 82(5), pp.472~474 (2005)
- M. Shamsipur, "Cadmium ion-selective electrode based on tetrathia-12-crown-4", Talanta, 53(5), pp.1065~1071 (2011)
- B. Rezaei,, "A fast response cadmium-selective polymeric membrane electrode based on N,N’-(4-methyl-1,2-phenylene) diquinoline-2-carboxamide as a new neutral carrier", Journal of Hazardous Materials, 153, pp.179~186 (2008)
- U. Khamjumphol, "New polymeric membrane cadmium(II)- selective electrodes using tripodal amine based ionophores", Analytica Chimica Acta, 704, pp.73~86 (2011)
- M. Javanbakht, "Cadmium(II)-selective membrane electrode based on a synthesized tetrol compound", Analytica Chimica Acta, 408, pp.75~81 (2000)