In the present study, real-time analytical method was developed to monitor the sudden chemical discharge or accident. Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) coupled with online headspace technique was applied to evaluate the feasibility of 12 organic compounds in aqueous samples for the first time in Korea. Target compounds were calibrated at five points ranged from 0.5 to 5 mg/L. As a result, the correlation coefficients of calibration curves were in the range of 0.92-0.99. From the repeated measurements, the limit of quantification (LOQ) was ranged between 0.11 and 1.28 mg/L. In the fugacity approach (closed system, steady-state assumption) transport of chemicals into the headspace is highly correlated with the air-water partition coefficient (KAW). 1,1-dichloroethene and propylene oxide showed quadratic types of calibration curves due to relatively high KAW values. These studies showed that the most organic compounds were clearly detected compared with Korean ambient water analytical guidelines. Thus, with further improvements in the increase of sensitivity and the number of detectable compounds could be a valuable online aquatic monitoring strategy.
Abstract
In the present study, real-time analytical method was developed to monitor the sudden chemical discharge or accident. Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) coupled with online headspace technique was applied to evaluate the feasibility of 12 organic compounds in aqueous samples for the first time in Korea. Target compounds were calibrated at five points ranged from 0.5 to 5 mg/L. As a result, the correlation coefficients of calibration curves were in the range of 0.92-0.99. From the repeated measurements, the limit of quantification (LOQ) was ranged between 0.11 and 1.28 mg/L. In the fugacity approach (closed system, steady-state assumption) transport of chemicals into the headspace is highly correlated with the air-water partition coefficient (KAW). 1,1-dichloroethene and propylene oxide showed quadratic types of calibration curves due to relatively high KAW values. These studies showed that the most organic compounds were clearly detected compared with Korean ambient water analytical guidelines. Thus, with further improvements in the increase of sensitivity and the number of detectable compounds could be a valuable online aquatic monitoring strategy.
참고문헌 (15)
- 이태형, "화학사고에 의한 인명사고 특성 분석에 관한 연구", 한국화재소방학회 논문지, 31(1), pp.81~88 (2017), 한국화재소방학회[DOI]
- 최현구, "수질모형을 이용한 수질오염사고의 모의분석", 환경영향평가, 23(3), pp.177~186 (2014), 한국환경영향평가학회[DOI]
- 이재균, "국내 수질오염사고 현황 분석과 대응 체계", 한국습지학회지, 15(4), pp.529~534 (2013), 한국습지학회
- S. P. Kourniotis, "Statistical analysis of domino chemical accidents", J. Hazard Mater., 71, pp.239~252 (2000)[DOI]
- 김기준, "PTR-TOF-MS를 이용한 화학사고 원인물질 분석 연구-에폭시와 아크릴산 이상 반응에 의한 사고 사례-", 환경분석과 독성보건, 17(1), pp.21~28 (2014), 한국환경분석학회
- G. He, "Managing major chemical accidents in China: Towards effective risk information", J. Hazard Mater., 187, pp.171~181 (2011)[DOI]
- Lee, H., "Improvements of safety management system in Korean chemical industry after a large chemical accident", Journal of Loss Prevention in the Process Industries, 42, pp.6~13 (2016)[DOI]
- S. C. Lee, "Volatile organic compounds (VOCs) in urban atmosphere of Hong Kong", Chemosphere, 48, pp.375~382 (2002)[DOI]
- 허성남, "낙동강수계 휘발성유기화합물질 모니터링 및 위해성 평가", 환경분석과 독성보건, 15(3), pp.188~196 (2012), 한국환경분석학회
- D. Smith, "Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis", Mass Spectrom. Rev., 24, pp.661~700 (2005)[DOI]
- I. P. Spane, "Analysis of formaldehyde in the headspace of urine from bladder and prostate cancer patients using selected ion flow tube mass spectrometry", Rapid Commun. Mass Spectrom, 13, pp.1354~1359 (1999)[DOI]
- R. A. Allardyce, "Detection of volatile metabolites produced by bacterial growth in blood culture media by selected ion flow tube mass spectrometry (SIFT-MS)", J. Microbiol. Methods, 65, pp.361~365 (2006)[DOI]
- D. Smith, "Direct, rapid quantitative analyses of BVOCs using SIFT-MS and PTR-MS obviating sample collection", TrAC Trends in Analytical Chemistry, 30, pp.945~959 (2011)[DOI]
- EPA, "U. Estimation Programs Interface SuiteTM for Microsoft<TEX>$^{(R)}$<", TEX> Windows, v 4.1, 2018
- S. Xu, "Evaluation of the three-phase equilibrium method for measuring temperature dependence of internally consistent partition coefficients (K(OW), K(OA), and K(AW)) for volatile methylsiloxanes and trimethylsilanol", Environ. Toxicol. Chem., 33, pp.2702~2710 (2014)[DOI]