시안 이온 선택성 Poly(aniline) 고체 접촉 전극
Cyanide Ion Selective Poly(aniline) Solid Contact Electrode
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Cyanide ion selective poly(aniline) solid contact electrode based on quinine-Ni ionophore as a sensing material is successfully developed. The electrode exhibits good linear response of -50.2 mV/decade (at 20±0.2oC,r^2=0.9993) within the concentration range of 1×10^-1.00~1×10^-5.74 M of NaCN solution. The composition of this electrode was quinine-Ni ionophore 3.0 : polyvinylchloride 30.0 : dibutylphthalate 67.0. When we consider the results of using different plasticizers had the best result in response characteristics. The electrode shows good selectivity for cyanide ion in comparison with any other anions and is suitable for use with aqueous solutions of pH 5.3~7.8. Their standard deviation in the measured emf differences was ±1.60 mV at cyanide sample solution of 1.0×10^-2 M and ±1.12 mV at cyanide sample solution of 1.0×10^-3 M. Their stabilization time was less than 15 mins and response time was less than 52 sec.
Abstract
Cyanide ion selective poly(aniline) solid contact electrode based on quinine-Ni ionophore as a sensing material is successfully developed. The electrode exhibits good linear response of -50.2 mV/decade (at 20±0.2oC,r^2=0.9993) within the concentration range of 1×10^-1.00~1×10^-5.74 M of NaCN solution. The composition of this electrode was quinine-Ni ionophore 3.0 : polyvinylchloride 30.0 : dibutylphthalate 67.0. When we consider the results of using different plasticizers had the best result in response characteristics. The electrode shows good selectivity for cyanide ion in comparison with any other anions and is suitable for use with aqueous solutions of pH 5.3~7.8. Their standard deviation in the measured emf differences was ±1.60 mV at cyanide sample solution of 1.0×10^-2 M and ±1.12 mV at cyanide sample solution of 1.0×10^-3 M. Their stabilization time was less than 15 mins and response time was less than 52 sec.
참고문헌 (22)
- R. R. Dasha, , J. Hazardous Materials, 163, pp.1~ (2009)
- X. Dai, , Minerals Engineering, 25, pp.1~ (2012)
- F. Gurbuz, , Journal of Hazardous Materials, 162, pp.74~ (2009)
- Y. B. Patil, , Process Biochemistry, 35, pp.1139~ (2000)
- M. I. Ezzi, , Enzyme and Microbial Technology, 31, pp.1042~ (2002)
- M. A. Barakat, , Applied Catal- ysis B: Environmental, 53, pp.13~ (2004)
- A. R. Yeddou, , Minerals Engineering, 23, pp.32~ (2010)
- M. Ebel, , Chemosphere, 66, pp.816~ (2007)
- 이서래, "최신식품화학", pp.93~332 (1998), 신광출판사
- 유해물질연구회, "유해화학물질편람" (1991), 동화기술
- 박선구, , 한국환경분석학회지, 2(1), pp.1~ (1999)
- D. Shan, , Anal. Chem., 20(12), pp.390~ (2004)
- A. E. Lindsay, , Anal. Chim. Acta, 558(1-2), pp.158~ (2006)
- Z. Li, , Macromolecules, 41(20), pp.7433~ (2008)
- F. Garcia, , Chemón. Commun., 22, pp.2790~ (2005)
- R. B. Fisher, , J. Chem. Edu., 51(6), pp.347~ (1974)
- E. Pungor, , Analyst, 95, pp.625~ (1970)
- G. J. Heijin, , Anal. Chim. Acta, 89, pp.287~ (1977)
- A. K. Covington, "Ion-Selective Electrode Methodoloy", pp.1~2 (1980), CRC Press
- W. Simon, "Ion-Selective Sensor", Pure Appl. Chem., 28, pp.811~ (1971)
- W.S. Han, , J. Anal. Chem., 66(9), pp.854~ (2011)
- 한원식, "Quinine-Cd 착물을 Ionophore로 이용한 Iodide 이온 선택성 고체 접촉 전극", 한국환경분석학회지, 14(4), pp.185~191 (2011), 한국환경분석학회