Delay Column과 on-line SPE LC-MS/MS 시스템을 이용한 수중에 과불화화합물의 분석
Analysis of Perfluorinated Compounds (PFCs) in Water using a Delay Column and an On-line SPE LC-MS/MS System
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
To ensure the safety of the citizens of Daegu with respect to drinking water sources, we continuously monitored trace pollutants in the Nakdong River basin. Perfluorinated compounds (PFCs) had been detected in the Nakdong River previously; thus, further low-concentration detection is required. We developed an LC-MS/MS analysis method using the online SPE approach for fast and simple detection of low-concentration PFCs. In this process, a delay column was used to assess PFC contamination. As a result, quality control analysis of eight standard PFCs using this method showed strong correlations, with correlation coefficients of 0.991 and more, and the limit of quantification was 0.5 to 1.7 ng/L. The recovery rates of PFCs from samples ranged from 75.3% ± 1.23% to 118.0% ± 1.39%, suggesting robustness of this method. Analyses of PFC at seven sampling points in the Nakdong River basin showed high PFC concentrations at the point where effluent from a sewage treatment plant was introduced. PFHxS, PFOA, and PFOS values, which were used as drinking water monitoring standards of treated water at the Daegu advanced water treatment plant, did not exceed the monitoring standards. Therefore, these results demonstrate that the established method is appropriate as an analytical tool for assessing low-concentration PFCs in drinking water.
Abstract
To ensure the safety of the citizens of Daegu with respect to drinking water sources, we continuously monitored trace pollutants in the Nakdong River basin. Perfluorinated compounds (PFCs) had been detected in the Nakdong River previously; thus, further low-concentration detection is required. We developed an LC-MS/MS analysis method using the online SPE approach for fast and simple detection of low-concentration PFCs. In this process, a delay column was used to assess PFC contamination. As a result, quality control analysis of eight standard PFCs using this method showed strong correlations, with correlation coefficients of 0.991 and more, and the limit of quantification was 0.5 to 1.7 ng/L. The recovery rates of PFCs from samples ranged from 75.3% ± 1.23% to 118.0% ± 1.39%, suggesting robustness of this method. Analyses of PFC at seven sampling points in the Nakdong River basin showed high PFC concentrations at the point where effluent from a sewage treatment plant was introduced. PFHxS, PFOA, and PFOS values, which were used as drinking water monitoring standards of treated water at the Daegu advanced water treatment plant, did not exceed the monitoring standards. Therefore, these results demonstrate that the established method is appropriate as an analytical tool for assessing low-concentration PFCs in drinking water.
참고문헌 (26)
- H. Fromme, "Perfluorinated compounds-exposure assessment for the general population in western countries", Int. J. Hyg. Environ. Health, 212, pp.239~270 (2009)
- J. P Giesy, "Golbal distribution of perfluorooctane sulfonate in wildlife", Environ. Sci. Technol, 35, pp.1339~1342 (2001)
- R. Renner, "Concerns over common perfluorinated surfactant", Environ. Sci. Technol (2003)[DOI]
- US EPA, "Perfluorooctyl sulfonates: proposed significant new use rule, Fed.Regis", 62319~62333 (2000)
- A. Y. Lin, "The impact of semiconductor, electronics and optoelectronic industries on downstream perfluorinated chemical contamination in Taiwanese rivers", Environ. Pollut, 157, pp.1365~1372 (2009)
- R. Renner, "Growing concern over perfluorinated chemicals", Environ. Sci. Technol, 35, pp.154~160 (2001)
- F. Hekster, "Environmental and toxicity effects of perfluoroalkylated substances", Rev, Environ. Contam. Toxicol, 179, pp.99~121 (2003)
- M. M. Schultz, "Quantitative determination of fluorinated alkyl substances by largevolume-injection liquid chromatography tandem mass spectrometry-characterization of municipal wastewaters", Environ. Sci. Technol, 40, pp.289~295 (2006)
- G. L. Kennedy, "The toxicology of perfluorooctanoate", Crit. Rev. Toxicol, 34, pp.351~384 (2004)
- A. Peden, "Suppression of humoral immunity in mice following exposure to perfluorooctane sulfonate", Toxicol. Sci, 104, pp.144~154 (2008)
- 수돗물 중 미규제 미량유해물질 관리방안 연구(Ⅳ), "국립환경과학원", 국립환경과학원, ~ (2016)
- 취·정수장 미량유해물질 안전성 제고방안 최종보고서, "부산대학교 산학협력단", 부산대학교 산학협력단, ~ (2018)
- 환경부, "먹는물 수질감사항목 운영 등에 관한 고시", ~ (2018)
- US EPA METHOD 537, "Determination of selected perfluorinated alkyl acids in drinking water by solid phase extraction and liquid chromatography", tandem mass spectrometry(LC, MS), 2009[DOI]
- 손희종, "On-Line SPE-LC", MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석, 2013, pp.35(2), 75~83[DOI]
- M. Mazzoni, "On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters", Journal of Analytical Methods in Chemistry, 2015 (2015)
- 환경부, "먹는물 수질감시항목 시험방법, 31. 과불화화합물-액체크로마토그래프-텐덤질량분석법", ~ (2019)
- Analysis of Per, "Polyfluoroalkyl Substanves in Water Using an Agilent 6470 Triple Quadrupole LC", MS, Agilent Technologies, pp.2017, ~[DOI]
- A low Femtogram Target Screen Method for Perfluoronated Compounds in Food Matrices and Potable 18. Water Using the Agilent 6460 Triple Auadrupole LC, "MS System Equipped with Agilent Jet Stream Technology", P. Stone, 2010, 5990-5313EN
- Automated On-line SPE-LC, "MS", MS Method for Perfluorinated Compounds in Water Samples, GERSTEL, pp.2017, 190~
- An ideal solution for trace level analysis with LC, "MS", MS, Agilent Technologies, pp.2020, ~[DOI]
- 손희종, "낙동강 수계에서의 과불화 화합물(PFCs) 검출 특성", 대한환경공학회지, 35(2), pp.84~93 (2013), 대한환경공학회
- S. Valsecchi, "Occurrence and sources of perfluoroalkyls acids in Italian river basins", Chemosphere, 129, pp.126~134 (2014)
- E. Sinclair, "Mass Loading and fate of perfluroalkyl surfactants in wastewater treatment plants", Environ. Sci. Technol, 40, pp.1408~1414 (2006)
- USEPA, "PFOA and PFOS : Treatment and Analytics", 12th CECIA-IAUPR Symposium (2017)
- 임채승, "고도 정수처리장에서의 과불화합물 거동", 상하수도학회지, 34(5), pp.323~334 (2020), 대한상하수도학회