피부 활성점 측정을 위한 회로설계 및 측정방법연구
A Study on the circuit design and measurement method for the measurement of active points on skin
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
피부 활성점(경혈) 측정 방법은 편리성, 저비용 및 비 침습으로 측정하기 때문에 많은 생체정보를 얻기 위한 기술이다. 본연구에서는 피부 아래에 활성점을 측정할 수 있는 장점이 있는 3전극 측정방법을 사용되었다. 임피던스측정방법은 측정실험결과와 관련성이 있는 등가전기회로를 통해서 증명되었다. 활성점의 특성주파수는 주변 피부보다 15-30Hz 높고, 리액턴스는35-77kΩ 더 작게 측정되었다. 이 기술은 비침습 측정 시스템을 이용해서 활성점과 주변피부의 리액턴스와 특성주파수를 정확하고 객관적으로 분석되었다.
Abstract
The method of measuring skin active points is a technique for obtaining a lot of biometric information because it ismeasured with convenience, low cost and non-invasive methods. In this paper, we used in a three electrode measuremethod that has the advantage of measuring the impedance of the APs under the skin. The impedance measuring methodis well illustrated by a simple model of an equivalent electrical circuit that correlates well with experimental results. Thecharacteristic frequencies of APs are about 15-30HZ higher than that of surrounding skin and the values of measuredreactance are about 35-77KΩ smaller. This technology analyzed accurately and objectively the reactance and characteristicfrequency of APs and the surrounding skin using a non-invasive measuring system.
참고문헌 (18)
- H. Jain, "Electrical impedance tomography of complex conductivity distributions with noncircular boundary", IEEE Trans. Biomedical Engineering, 44, pp.1051~1060 (1997)[DOI]
- S. Grimnes, "Impedance measurement of individual skin surface electrodes", Med. Biol. Eng. Comput, 21, pp.750~755 (1983)[DOI]
- O. G. Martinsen, "Electrical methods for skin moisture assessment", skin Pharmacol, 8, pp.237~245 (1995)[DOI]
- J. Hyvarinen, "Low-resistance skin points that may coincide with acupuncture loci", Med. Biol, 55, pp.88~94 (1977)
- T. Croley, "Electrical acupuncture point conductance in the living compared to that in the dead", Am. J. Acupunct, 14, pp.57~60 (1986)[DOI]
- S. Rezaei, "Characterisation of human skin impedance at acupuncture point PC4 Ximen and pericardium meridian using the four-electrode method", Acupunct. Med, 30, pp.127~131 (2012)[DOI]
- R. Becker, "Electromagnetism and life" (1982), State University of New York Press
- W. Zhang, "The Influence of acupuncture on the impedance measured by four electrodes on meridians", Acupuncture Electro-Therap Res Int J, 24, pp.181~188 (1999)[DOI]
- N. Barlea, "Electrical detection of acupuncture points", Acta Electrotech Napocensis, 41, pp.59~61 (2000)
- H. Johng, "Frequency dependence of impedance at the acupuncture point Quze(PC3)", IEEE Eng. Med. Biol, 21, pp.33~36 (2002)[DOI]
- A. Comunetti, "Characteristics of human skin conductance at acupuncture point", Experientia, 51, pp.328~331 (1995)[DOI]
- M S Kim, "Electrical Characteristics Analysis of Biological Active Points using Real Time Measurement", The 2nd International Meeting on Microsensors and Microsystems, 166 (2006)
- Y. Nakatani, "Essai sur l,acupuncture Chinoise", Clinic of Chinese Medicine, 3(7), pp.54~ (1956)
- R. Voll, "Messbara acupuncture-diagnostic und Therapie fur den praktier", Erfahrungsheilkunde, 4 (1955)
- T. Yamamoto, "Measurement of low-resistance points on the skin by dry roller electrodes", IEEE Trans. Biomedical Eng, 35(3), pp.203~209 (1988)[DOI]
- E. F. Prokhorov, "In vivo electrical characteristics of human skin, including at biological active points", Med. Biol. Eng. Comput, 38, pp.507~511 (2000)[DOI]
- Li. Dachao, "A Method for Measuring the Volume of Transdermally Extracted Interstitial Fluid by a Three-Electrode Skin Resistance Sensor", Sensors, 14, pp.7084~7095 (2014)[DOI]