Abstract

Test turnaround time (TAT) is the lead time from reception to reporting. In the complete blood cell count (CBC), 4 units of the XE-2100 (Sysmex Corp., Japan) processed around 80% of quantity, 1 unit of the LH-780 (Beckman-Coulter Incorp., USA) processed around 10% and 1 unit of ADVIA-2120 (Siemens AG, Munich, Germany) processed around 10%. We analyzed the change in the TAT for the CBC for over 7 years, from January of 2005 to December of 2011. The delta check made alterations of delta to WBC, hemoglobin, hematocrit, platelet and metamyelocyte, however, did not made them to band neutrophil, eosinophil, basophil and monocyte. The panic value check made alterations of panic value to hemoglobin, hematocrit, platelet and monocyte. In the criteria of currently slide review, LH-780 and ADVI-2120 analyzers prepared suspect flags of “Blast, Imm NE2, Immature granulocyte, Imm NE1, Left shift, Variant lymphocyte, Atypical lymphocyte, Platelet clumps and NRBC”. The New slide review in the XE-2100 analyzer altered the preparations of a smear slide more than a “Platelet clumps flag(≥200 unit), a single flag excluding the “Platelet clumps flag (≥250 unit) and a multiple flag (≥200 unit)”. Also, below the 240 unit, medical technologists prepared manual slides selectively according to their evaluations. The automatic reporting rate was 33.4% without alterations, whereas it was 41.0% without alterations, and was thus improved by 7.6%. The slide review rate was 15.2% before using the Q-flag limit, whereas it was 12.1% for a reduce 3.1%. TAT was 45 minutes without the creation alterations of the delta and panic value checks, whereas it was 35 minutes after making alterations of the delta and panic value checks and thus was shortened by 10 minutes. We came to the conclusion that the establishment and operation of delta and panic value checks and slide review criteria suitable for laboratory environment can reduce unnecessary smear slides, re-checking, re-sampling, re-testing, telephone inquiries and concentrated workloads during specific times of the day.

참고문헌 (16)

  1. Barnes PW, "The international consensus group for hematology review: Suggested criteria for action following automated CBC and WBC differential analysis", Lab Hematol, 11, pp.83~90 (2005)
  2. Ladenson JH, "Pateints as their own controls: use of the computer to identify “Laboratory Error”", Clin Chem, 21, pp.1648~1653 (1975)
  3. Lindberg DAB, "Collection, evaluation, and transmission of hospital laboratory data", Method Inform Med, 6, pp.97~107 (1967)
  4. Nosanchuk JS, "CUMS and Delta Checks; A systematic approach to quality control", Am J Clin Pathol, 62, pp.707~712 (1974)
  5. Novis DA, "Laboratory productivity and the rate of manual peripheral blood smear review: A college of American pathologists Q-probes study of 95,141 complete blood count determinations performed in 263 institutions", Arch Pathol Lab Med, 130, pp.596~601 (2006)
  6. Pelegri MD, "Improvement of emergency and routine turnaround time by data processing and instrument changes", Clin Chim Acta, 248, pp.62~72 (1996)
  7. Steindel SJ, "Timesliness of automatied routine laboratory tests: a College of American Pathologists Q-Probes study on 653 institutions", Clin Chim Acta, 251, pp.25~40 (1996)
  8. Roussel M, "Refining the white blood cell differential: The first flow cytometry routine application", Cytometry A, 77, pp.552~563 (2010)
  9. 김종원, "임상화학검사의 다변량 변화치 검색(multivariate delta check)에 관한 연구", 임상검사와 정도관리, 12, pp.69~74 (1990)
  10. 김종원, "경고치 검색과 변화치 검색", 임상검사와 정도관리, 15(56), pp.19~ (2004)
  11. 박효순, "자동혈구 분석기의검사결과 전산처리에 관한 연구-H-1 System을 중심으로", 대한진단검사의학회지, 9, pp.49~58 (1989)
  12. 양윤선, "CBC의 Histogram 판독과 Delta 및 Panic치 검산의 경험", 임상검사와 정도관리, 13, pp.201~204 (1991)
  13. 이성규, "검사실 정보 시스템을 이용한 농축적혈구 불출 소요시간의 분석", 임상검사와 정도관리, 28, pp.199~206 (2006)
  14. 이우창, "외래 자동화검사실 재조직화에 의한 검사 소요시간 단축", Annals of Laboratory Medicine, 24(5), pp.334~338 (2004), 대한진단검사의학회
  15. 양용석, "최신임상혈액학", pp.96~ (2001), 대학서림
  16. 조한익, "실용혈액학", pp.39~ (1997), 고려의학

관련 논문AI추천

Effective and Practical Complete Blood Count Delta Check Method and Criteria for the Quality Control of Automated Hematology AnalyzersCho Young-Uk, Jang Seongsoo, Kim Min-Sun, Kim Seung-Il, Namgoong Seung, Park Chan-Jeoung대한진단검사의학회 · Annals of Laboratory Medicine2023 · 제43권 제5호LH 750에 의한 백혈구 감별계산 및 Suspect Flags의 평가김현수, 이성규, 최종태, 홍승복대한임상검사과학회 · 대한임상검사과학회지2005 · 제37권 제3호Validation of Hematology Rapid Reporting System for Complete Blood Cell Count with Differential김지용, 박지영, 윤수영, 이정민대한진단검사의학회 · Laboratory Medicine Online2022 · 제12권 제1호SE-9000 자동 혈구계산기에서 EDTA 검체의 보관기간 및 온도가 CBC 및 백혈구 감별계산에 미치는 영향김종석, 신경섭, 홍승복대한임상검사과학회 · 대한임상검사과학회지2006 · 제38권 제3호Current Status and Proposal of a Guideline for Manual Slide Review of Automated Complete Blood Cell Count and White Blood Cell Dfferential권계철, 김영재, 김희진, 박효순, 신상용, 우희연, 이영경, 장윤환, 조성란, 채석래, 최종락, 한경자대한진단검사의학회 · Annals of Laboratory Medicine2010 · 제30권 제6호자동혈구분석기 XE-2100, ADVIA-120와 Manual Differential Count의 상관성 및 Morphology Flag 평가박효순, 변남섭, 송순영, 유선우, 이범희, 지명석대한임상검사과학회 · 대한임상검사과학회지2004 · 제36권 제2호

이 간행물의 다른 논문 (7건)