본문 바로가기
KERD
논문KCI 등재

Estimation of Angular Insertion Depth of a Cochlear Implant Electrode Array: Three-Dimensional Reconstruction Versus Spiral Formulae

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Objectives. The primary objective was to determine which of the following angular insertion depth (AID) estimation methods showed the strongest correlation with the postoperative AID (AIDpostop) of a lateral wall (LW) electrode: the Escudé formula, based on the largest distance from the round window (RW) to the LW (distance A); the elliptic-circular approxi- mation (ECA) method, based on both distance A and the perpendicular distance (distance B); and a three-dimensional (3D) reconstruction method. The secondary objective was to assess the impact of using the actual electrode insertion length on the evaluation of AID estimation methods. Methods. This study included 45 cochleae implanted with the Advanced Bionics SlimJ electrode, with all 16 active electrode contacts positioned intracochlear. Distance A, distance B, and a 3D reconstruction along the LW were evaluated on preoperative magnetic resonance imaging using 3D Slicer. The AIDpostop and insertion length were assessed using cone- beam computed tomography. Two sets of estimated AID values were obtained: assuming a perfect 23-mm insertion length with the reference electrode at the RW (AID23mm); and using the actual insertion length (AIDinsertionlength). Spear- man’s rank correlation coefficient was used to assess the association between the estimated AID values and AIDpostop. Results. A moderately positive correlation was observed between AID23mm and AIDpostop for all three approaches, with no statistically significant differences among them (rs = 0.410–0.579). When the analysis was repeated using AIDinsertionlength, the strength of the correlation with AIDpostop increased significantly for all three methods, with the 3D reconstruction method showing a stronger correlation (rs = 0.952) than the Escudé formula (rs = 0.734) or the ECA method (rs = 0.787) (P <0.001). Conclusion. The 3D reconstruction approach has the potential to improve prediction of the AID for LW electrode arrays compared to spiral formulae based on 2D cochlear dimensions. Accurate assessment of the actual insertion length is important for the proper evaluation of AID estimation methods.

Abstract

Objectives. The primary objective was to determine which of the following angular insertion depth (AID) estimation methods showed the strongest correlation with the postoperative AID (AIDpostop) of a lateral wall (LW) electrode: the Escudé formula, based on the largest distance from the round window (RW) to the LW (distance A); the elliptic-circular approxi- mation (ECA) method, based on both distance A and the perpendicular distance (distance B); and a three-dimensional (3D) reconstruction method. The secondary objective was to assess the impact of using the actual electrode insertion length on the evaluation of AID estimation methods. Methods. This study included 45 cochleae implanted with the Advanced Bionics SlimJ electrode, with all 16 active electrode contacts positioned intracochlear. Distance A, distance B, and a 3D reconstruction along the LW were evaluated on preoperative magnetic resonance imaging using 3D Slicer. The AIDpostop and insertion length were assessed using cone- beam computed tomography. Two sets of estimated AID values were obtained: assuming a perfect 23-mm insertion length with the reference electrode at the RW (AID23mm); and using the actual insertion length (AIDinsertionlength). Spear- man’s rank correlation coefficient was used to assess the association between the estimated AID values and AIDpostop. Results. A moderately positive correlation was observed between AID23mm and AIDpostop for all three approaches, with no statistically significant differences among them (rs = 0.410–0.579). When the analysis was repeated using AIDinsertionlength, the strength of the correlation with AIDpostop increased significantly for all three methods, with the 3D reconstruction method showing a stronger correlation (rs = 0.952) than the Escudé formula (rs = 0.734) or the ECA method (rs = 0.787) (P <0.001). Conclusion. The 3D reconstruction approach has the potential to improve prediction of the AID for LW electrode arrays compared to spiral formulae based on 2D cochlear dimensions. Accurate assessment of the actual insertion length is important for the proper evaluation of AID estimation methods.

관련 논문AI추천

Potential Implications of Slim Modiolar Electrodes for Severely Malformed Cochleae: A Comparison With the Straight Array With Circumferential Electrodes이상연, 최병윤대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2021 · 제14권 제3호Precision Medicine Approach to Cochlear Implantation김예리, 최병윤대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2022 · 제15권 제4호Cochlear Implants for Patients With Common Cavity Deformities and the Impact of Electrode Positioning배성훈, 최재영, 최지훈대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2022 · 제15권 제1호Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types강시형, 김은연, 문일준, 백은주, 설혜윤, 이지영, 홍성화대한청각학회 · Journal of Audiology & Otology2019 · 제23권 제3호Endoscope-Assisted Cochlear ImplantationEnis Alpin Güneri, Yüksel Olgun대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2018 · 제11권 제2호Robotic Versus Manual Electrode Insertion in Cochlear Implant Surgery: An Experimental StudyAbdulaziz Alballaa, Abdulrahman Alsanosi, Abdulrahman Hagr, Asma Alahmadi, Farid Alzhrani, Fida Almuhawas, Ibrahim Shami, Marco Matulic, Mariam Al-Amro, Masoud Zoka Assadi, Maximilian Stichling, Salman F Alhabib, Tahir Sharif, Yassin Abdelsamad대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2025 · 제18권 제1호

이 간행물의 다른 논문 (8건)