Comparison of the Digene HPV Genotyping LQ Test and the PANArray HPV Genotyping Chip for Detection of High-Risk or Probable High-Risk Human Papillomavirus Genotypes
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background: We evaluated the performance of two different array-based techniques, a bead-based multiplex genotyping method (LQ; digene HPV Genotyping LQ Test, QIAGEN, Germany) and a DNA chip-based method using peptide nucleic acid probes (PANArray; PANArray HPV Genotyping Chip, Panagene, Korea), for detection of human papillomavi- rus (HPV) and genotyping of high-risk (HR) or probable high-risk (PHR) HPVs in healthy patients who visited a health-promotion center. Methods: We obtained 508 unselected, consecutive cervicovaginal swab specimens. All specimens were examined by using the PANArray and LQ tests. All HPV-positive samples were then analyzed by multiplex PCR and direct sequencing. Results: The LQ test detected 47 HPV-positive cases (9.3%) with HR or PHR genotypes and the PANArray test identified 36 cases (7.1%). When the results of LQ and PANArray were compared by using comprehensive genotyping (integrated interpretation of the re- sults of LQ, PANArray, multiplex PCR, and direct sequencing) for the detection of HR or PHR genotypes, the kappa values were 0.44 and 0.30 for LQ and PANArray, respectively. In comparison to comprehensive genotyping, the LQ test yielded 53 (60.0%) concordant and 12 (13.5%) compatible results, and the PANArray yielded 36 (40.4%) concordant and three (3.4%) compatible results. Conclusions: The results of the LQ test had higher concordance and/or greater compati- bility with those of comprehensive genotyping for the detection of HR or PHR genotypes than those of the PANArray test.
Abstract
Background: We evaluated the performance of two different array-based techniques, a bead-based multiplex genotyping method (LQ; digene HPV Genotyping LQ Test, QIAGEN, Germany) and a DNA chip-based method using peptide nucleic acid probes (PANArray; PANArray HPV Genotyping Chip, Panagene, Korea), for detection of human papillomavi- rus (HPV) and genotyping of high-risk (HR) or probable high-risk (PHR) HPVs in healthy patients who visited a health-promotion center. Methods: We obtained 508 unselected, consecutive cervicovaginal swab specimens. All specimens were examined by using the PANArray and LQ tests. All HPV-positive samples were then analyzed by multiplex PCR and direct sequencing. Results: The LQ test detected 47 HPV-positive cases (9.3%) with HR or PHR genotypes and the PANArray test identified 36 cases (7.1%). When the results of LQ and PANArray were compared by using comprehensive genotyping (integrated interpretation of the re- sults of LQ, PANArray, multiplex PCR, and direct sequencing) for the detection of HR or PHR genotypes, the kappa values were 0.44 and 0.30 for LQ and PANArray, respectively. In comparison to comprehensive genotyping, the LQ test yielded 53 (60.0%) concordant and 12 (13.5%) compatible results, and the PANArray yielded 36 (40.4%) concordant and three (3.4%) compatible results. Conclusions: The results of the LQ test had higher concordance and/or greater compati- bility with those of comprehensive genotyping for the detection of HR or PHR genotypes than those of the PANArray test.
참고문헌 (22)
- Bernard HU, "Classification of papillomaviruses (PVs) based on 189 PV types and proposal of taxonomic amendments", Virology, 401, pp.70~79 (2010)
- Muñoz N, "Epidemiologic classification of human papillomavirus types associated with cervical cancer", N Engl J Med, 348, pp.518~527 (2003)
- Bouvard V, "A review of human carcinogens--Part B: biological agents", Lancet Oncol, 10, pp.321~322 (2009)
- Poljak M, "Commercially available assays for multiplex detection of alpha human papillomaviruses", Expert Rev Anti Infect Ther, 8, pp.1139~1162 (2010)
- 황유선, "Comparison of the AdvanSure Human Papillomavirus Screening Real-Time PCR, the Abbott RealTime High Risk Human Papillomavirus Test, and the Hybrid Capture Human Papillomavirus DNA Test for the Detection of Human Papillomavirus", Annals of Laboratory Medicine, 32(3), pp.201~205 (2012), 대한진단검사의학회[DOI]
- Loy A, "Highly parallel microbial diagnostics using oligonucleotide microarrays", Clin Chim Acta, 363, pp.106~119 (2006)
- Clewley JP, "A role for arrays in clinical virology: fact or fiction?", J Clin Virol, 29, pp.2~12 (2004)
- Godínez JM, "Performance of the digene LQ, RH and PS HPVs genotyping systems on clinical samples and comparison with HC2 and PCR-based Linear Array", Infect Agent Cancer, 6, pp.23~ (2011)
- Geraets DT, "Universal human papillomavirus genotyping by the digene HPV Genotyping RH and LQ Tests", J Clin Virol, 50, pp.276~280 (2011)
- Zubach V, "Novel microsphere-based method for detection and typing of 46 mucosal human papillomavirus types", J Clin Microbiol, 50, pp.460~464 (2012)
- Cho EJ, "Evaluation of a liquid bead array system for high-risk human papillomavirus detection and genotyping in comparison with Hybrid Capture II, DNA chip and sequencing methods", J Med Microbiol, 60, pp.162~171 (2011)
- Kim C, "Peptide nucleic acid-based array for detecting and genotyping human papillomaviruses", Journal of Clinical Microbiology, 47(6), pp.1785~1790 (2009), American Society for Microbiology
- Husnjak K, "Comparison of five different polymerase chain reaction methods for detection of human papillomavirus in cervical cell specimens", J Virol Methods, 88, pp.125~134 (2000)
- Gravitt PE, "Improved amplification of genital human papillomaviruses", J Clin Microbiol, 38, pp.357~361 (2000)
- Nishiwaki M, "Genotyping of human papillomaviruses by a novel one-step typing method with multiplex PCR and clinical applications", J Clin Microbiol, 46, pp.1161~1168 (2008)
- Geraets DT, "High-throughput genotyping of high-risk HPV by the digene HPV Genotyping LQ Test using GP5+", 6+-PCR and xMAP technology, 2009, pp.46(3), 21~26
- Lee JK, "Comparison of Human Papillomavirus Detection and Typing by Hybrid Capture 2, Linear Array, DNA Chip, and Cycle Sequencing in Cervical Swab Samples", INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 19, pp.266~272 (2009), BLACKWELL PUBLISHING
- Song SH, "Clinical performance assessment of five human papillomavirus DNA tests using liquid-based cytology samples", JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 38, pp.408~414 (2012), BLACKWELL PUBLISHING
- Chung MY, "Development of a bead-based multiplex genotyping method for diagnostic characterization of HPV infection", PLoS One, 7, pp.e32259~ (2012)
- Schmitz M, "Quantitative multiplex PCR assay for the detection of the seven clinically most relevant high-risk HPV types", J Clin Virol, 44, pp.302~307 (2009)
- Carcopino X, "Significance of HPV 16 and 18 viral load quantitation in women referred for colposcopy", J Med Virol, 84, pp.306~313 (2012)
- Gharizadeh B, "Type-specific multiple sequencing primers: a novel strategy for reliable and rapid genotyping of human papillomaviruses by pyrosequencing technology", J Mol Diagn, 7, pp.198~205 (2005)