본문 바로가기
KERD
논문KCI 등재

Thermal radiation assessment of flaring gas in floating LNG bunkering terminal

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

A floating LNG bunkering terminal (FLBT) is a marine unit capable of receiving LNG through an LNG carrier and storing LNG and bunkering fuel into LNG-fueled vessels using an LNG bunkering shuttle. The FLBT is accompanied by LNG bunkering-related processes, such as loading/unloading, reliquefaction, and gas flare, within a limited space on the vessel. The heat radiated from the flaring gases causes the personnel working on the FLBT platform to be frequently exposed to risks that may be lethal. Therefore, for safety purposes, a quantitative evaluation of the thermal radiation of the ignited flare gas ejected from a flare tower is required to understand the hazards that the personnel, assets, and environment on the FLBT platform may be exposed to. In this study, the worst scenario that occurs in an emergency flaring was selected to assess the thermal radiation effect when the highest release of boil-off gas was ignited. Additionally, the acceptance of the thermal radiation level of the flaring gas was numerically analyzed and verified based on practical guidelines.

Abstract

A floating LNG bunkering terminal (FLBT) is a marine unit capable of receiving LNG through an LNG carrier and storing LNG and bunkering fuel into LNG-fueled vessels using an LNG bunkering shuttle. The FLBT is accompanied by LNG bunkering-related processes, such as loading/unloading, reliquefaction, and gas flare, within a limited space on the vessel. The heat radiated from the flaring gases causes the personnel working on the FLBT platform to be frequently exposed to risks that may be lethal. Therefore, for safety purposes, a quantitative evaluation of the thermal radiation of the ignited flare gas ejected from a flare tower is required to understand the hazards that the personnel, assets, and environment on the FLBT platform may be exposed to. In this study, the worst scenario that occurs in an emergency flaring was selected to assess the thermal radiation effect when the highest release of boil-off gas was ignited. Additionally, the acceptance of the thermal radiation level of the flaring gas was numerically analyzed and verified based on practical guidelines.

참고문헌 (17)

  1. "IMO Official Web Site"[URL]
  2. 김준호, "Evaluation of the ventilation safety requirements for the fuel gas supply system room of a gas-fueled vessel: simulated leaks of methane and propane", Journal of Mechanical Science and Technology, 32(11), pp.5521~5532 (2018), 대한기계학회
  3. 도덕희, "A swirl static mixer with diluent for reducing the flammable extent of venting gases in a low-flashpoint fueled vessel", Journal of Mechanical Science and Technology, 33(7), pp.3311~3321 (2019), 대한기계학회
  4. Floating LNG Bunkering Terminal HAZID Workshop Report, "Korean Register (KR)", ~, pp.KR-HSE-HAZD-RPT-008B (2015)
  5. A. Brandsæter, "Risk assessment in the offshore industry", Safety Science, 40(1-4), pp.231~269 (2002)
  6. Parameters for Properly Designed and Operat-ed Flares, "U. S. EPA Office of Air Quality Planning and Standards (OAQPS)", Flare Review Panel, ~ (2012)
  7. 김종민, "Dispersion analysis of the unignited flare gas in an LNG-FPSO vessel", 한국마린엔지니어링학회지, 41(8), pp.753~759 (2017), 한국마린엔지니어링학회[DOI]
  8. L. Xuejiang, "Thermal radiation and noise safety assessment of an offshore platform flare stack as sudden emergency relief takes place", International Journal of Mechanical and Mechatronics Engineering, 10(11), pp.1847~1850 (2016)
  9. Heon Seok Lee, "Reduction of thermal radiation by steam in flare stack system", Korean Journal of Chemical Engineering, 29(10), pp.1310~1320 (2012), 한국화학공학회[DOI]
  10. L. Xuejiang, "Thermal radiation and noise safety assessment of an offshore platform flare stack as sudden emergency relief takes place", International Journal of Mechanical and Mechatronics Engineering, 10(11), pp.1847~1850 (2016)
  11. A. Soni, "Flare radiation mitigation analy-sis of onshore oil & gas production & refining facility for a low cost be-bottlenecking using computer aided tech-niques", International Journal of Scientific & Engineering Research, 9(2), pp.975~982 (2018)
  12. "Pyrosim user manual"[URL]
  13. Fire dynamic simulator user’s guide, "K. McGrattan", NIST, ~, pp.NIST special publication 1019 (2017)
  14. Smokeview, a tool for visualizing fire dy-namics simulation data vol. I: user’s guide, "G. P. Forney", NIST, ~, pp.NIST special publication 1017-1 (2018)
  15. "FDS Technical reference guide vol. 1: mathe-matical model, vol. 2: verification, vol. 3: validation, 6th ed"[URL]
  16. B. C. Choi, "Impacts of cold gas temperature and cylindrical obstacles on the dispersing flammable limits of accidental methane releases in an LNG bunkering terminal", Journal of Hazardous Materials, 355, pp.104~110 (2018)
  17. American Petroleum Institute, "Pressure-relieving and depressuring systems 6th ed., API Standard 521", ~ (2014)

관련 논문AI추천

이 간행물의 다른 논문 (11건)