본문 바로가기
KERD
논문KCI 등재

The use of tantalum cones and diaphyseal-engaging stems in tibial component revision: a consecutive series

2

조회

0

다운로드

0

인용

0

참고문헌

초록

Revision knee arthroplasty presents a number of challenges, including management of bone loss. The goal in managing moderate to large bone defects is fixation that is sufficient enough to allow early weight-bearing. The purpose of this study was to describe the surgical technique and clinical and radiographic outcomes of patients treated with porous tantalum metaphyseal cones in combination with long uncemented diaphyseal-engaging stems to manage tibial bone loss in revision total knee arthroplasty (TKA).Thirty-six aseptic revision TKAs were performed at our institution between 2016 and 2019 by two senior authors. A single trabecular metal tantalum cone combined with a long (100 or 155 mm) press fit, diaphyseal-engaging stem was used in all cases to reconstruct metaphyseal bone defects and to augment tibial fixation. Cemented stems were excluded. The tibiofemoral angle was measured along the tibial and femoral shaft axes on the weight-bearing anteroposterior radiograph at final follow-up (range 15–56 months). All clinical and surgical complications, reoperations, and revisions of any component were recorded. Survivorship free of revision was evaluated at the time of the latest follow-up. The mean Knee Society Score (KSS) and Knee Society Function Score (KSS-F) improved significantly from 29.7 points preoperatively (range 11–54 points) to 86 points (range 43–99 points) and from 20.4 points preoperatively (range 0–55 points) to 72.3 points (range 30–90 points) ( p < 0.05), respectively. Eleven tibial constructs (30.5%) had incomplete, nonprogressive radiolucent lines (≤ 2 mm). All tibial cones demonstrated osteointegration. One patient underwent a full revision for periprosthetic joint infection, and survivorship free of any component revision was 91.7% at final follow-up. Hybrid fixation with uncemented diaphyseal-engaging stems and porous tantalum metaphyseal cones resulted in radiographic lack of osteolysis, good clinical outcomes, and survivorship of 91.7% at a median follow-up of 33 months when considering all-cause revision as the endpoint.

Abstract

Revision knee arthroplasty presents a number of challenges, including management of bone loss. The goal in managing moderate to large bone defects is fixation that is sufficient enough to allow early weight-bearing. The purpose of this study was to describe the surgical technique and clinical and radiographic outcomes of patients treated with porous tantalum metaphyseal cones in combination with long uncemented diaphyseal-engaging stems to manage tibial bone loss in revision total knee arthroplasty (TKA).Thirty-six aseptic revision TKAs were performed at our institution between 2016 and 2019 by two senior authors. A single trabecular metal tantalum cone combined with a long (100 or 155 mm) press fit, diaphyseal-engaging stem was used in all cases to reconstruct metaphyseal bone defects and to augment tibial fixation. Cemented stems were excluded. The tibiofemoral angle was measured along the tibial and femoral shaft axes on the weight-bearing anteroposterior radiograph at final follow-up (range 15–56 months). All clinical and surgical complications, reoperations, and revisions of any component were recorded. Survivorship free of revision was evaluated at the time of the latest follow-up. The mean Knee Society Score (KSS) and Knee Society Function Score (KSS-F) improved significantly from 29.7 points preoperatively (range 11–54 points) to 86 points (range 43–99 points) and from 20.4 points preoperatively (range 0–55 points) to 72.3 points (range 30–90 points) ( p < 0.05), respectively. Eleven tibial constructs (30.5%) had incomplete, nonprogressive radiolucent lines (≤ 2 mm). All tibial cones demonstrated osteointegration. One patient underwent a full revision for periprosthetic joint infection, and survivorship free of any component revision was 91.7% at final follow-up. Hybrid fixation with uncemented diaphyseal-engaging stems and porous tantalum metaphyseal cones resulted in radiographic lack of osteolysis, good clinical outcomes, and survivorship of 91.7% at a median follow-up of 33 months when considering all-cause revision as the endpoint.

관련 논문AI추천

Mid-term clinical and radiographic outcomes of porous-coated metaphyseal sleeves used in revision total knee arthroplastyAshlenazi Itay, Elbaz Etay, Gold Aviram, Gurel Ron, Kadar Assaf, Morgan Samuel, Snir Nimrod, Warschawski Yaniv대한슬관절학회 · Knee Surgery and Related Research2021 · 제33권 Stem Fixation in Revision Total Knee Arthroplasty: Indications, Stem Dimensions, and Fixation Methods송상준, Cheol Hee Park, Se Gu Kang대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제3호Bone loss in aseptic revision total knee arthroplasty: management and outcomesDaniel B. Buchalter, John J. Mercuri, Joshua C. Rozell, Schwarzkopf Ran, Thomas Bieganowski, Vinay K. Aggarwal, Vivek Singh대한슬관절학회 · Knee Surgery and Related Research2022 · 제34권 Full Cementation in Revision Total Knee Arthroplasty Using a Constrained Condylar Knee Prosthesis with an Average 7-Year Follow-up권기태, 김도훈, 이운상, 한규영대한슬관절학회 · Knee Surgery and Related Research2017 · 제29권 제4호Long-term Results of Hybrid Total Knee Arthroplasty: Minimum 10-years Follow-up김정환, 이기원, 최영준, 황재광, Hee Don Han, Hyung Sun Ahn, Jeong Ho Kang, Jun Seok Park, Wan Jong Cho대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제2호The additional tibial stem extension is not mandatory for the stability of 5 mm metal block augmented tibial prosthesis construct in primary total knee arthroplasty: 5-year minimum follow-up resultsChoong Hyeok Choi, Jae Joon Ryu, Yeong Hwan Kim대한슬관절학회 · Knee Surgery and Related Research2023 · 제35권

이 간행물의 다른 논문 (44건)