In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in 1st HF and 2nd HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio (1st HF bed : 2nd HF bed) of hydroponic wastewater was 60:40.
Abstract
In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in 1st HF and 2nd HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio (1st HF bed : 2nd HF bed) of hydroponic wastewater was 60:40.
참고문헌 (13)
- APHA, "Standard methods for the examination of water and wastewater. 19th ed", American Public Health Association (1995)
- Heyman, A. M., "Self-Financed Resource, A direct approach to maintaining marine biological diversity, Paper presented at workshop on economics", General assembl, pp.234~235 (1988)
- Kim, J. T., "The standard method of water analysis" (2001), Shinkwang a publishing company in Korea
- Korean Ministry of Environment, 2005, "Environmental White Book of 2005" (2005), Ministry of Environment Republic
- Lee, D. B., "Changes of chemical contents in groundwater at controlled horticulture in honam area", Kor. K. Environ. Agric., 15(3), pp.348~354 (1996)
- 이경자, "충북지역 양액 재배용 지하수 및 폐양액의 화학적 특징", 한국환경농학회지, 26(1), pp.42~48 (2007), 한국환경농학회
- Lee, S. Y., "Reusing techniques of Nutrient Solution for recycling hydroponic culture of lettuce", J. Bio. Env. Con., 80(3), pp.172~182 (1999)
- MAF, "Agricultural and forestry statistical yearbook", pp.1~316 (2009), Ministry of Agriculture and Agriculture and Forestry
- 박우영, "시설하우스 폐양액 처리를 위한 소형 인공습지의 최적 조합방법, 여재깊이 및 폐양액 부하량", 한국환경농학회지, 27(3), pp.217~224 (2008), 한국환경농학회
- Seo, B. S., "Future prospects and countermeasures for hydroponics in 21C", Kor. J. Hort. Sci. Technol., 17, pp.796~802 (1999)
- Seo, D. C., "Development of treatment process of biological nitrogen and phosphorus in sewage treatment plant by natural purification system. in: Doctor Thesis" (2005), Gyeongsang National University of Education
- 서동철, "자연정화공법에 의한 인공습지 하수처리장에서 최적 수생식물의 선정", 한국환경농학회지, 25(1), pp.25~33 (2006), 한국환경농학회
- 서동철, "자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안", 한국환경농학회지, 27(1), pp.27~34 (2008), 한국환경농학회