Purpose: We analyzed the microstructure and bone mineral density (BMD) of the trabecular bone in the femoral head of patients with osteoporosis. Materials and Methods: Sixteen femoral heads with osteoporotic femoral neck fractures underwent microcomputed tomography scanning. In each tip-apex distance (TAD) of 15, 20, and 25 mm, five regions of interest (ROIs) were extracted from the central, anterior, posterior, superior, and inferior sections. A total of 15 ROIs were extracted from TADs of 15, 20, and 25 mm. The measurement parameters included BMD, percent bone volume: bone volume/total volume (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), structural model index (SMI), and degree of anisotropy (DOA). Results: The lowest BMD and BV/TV values were observed in the inferior region and differed significantly from those in other regions (P<0.05). Lower Tb.Th and Tb.N values were observed in the inferior region compared with those in the central region (P<0.05). The highest SMI value was observed in the inferior region (P<0.05). With TAD of 15 and 20 mm, the DOA values in the inferior region were lower than those in the anterior region (P<0.05). Lower BMD and BV/TV values were observed in the anterior, central, and inferior regions of TAD of 15 mm compared with those in the corresponding regions of TAD of 25 mm (P<0.05). Conclusion: Positioning the lag screw between TAD of 20 to 25 mm and in the inferior region is recommended, and TAD of less than 15 mm is not recommended.
Abstract
Purpose: We analyzed the microstructure and bone mineral density (BMD) of the trabecular bone in the femoral head of patients with osteoporosis. Materials and Methods: Sixteen femoral heads with osteoporotic femoral neck fractures underwent microcomputed tomography scanning. In each tip-apex distance (TAD) of 15, 20, and 25 mm, five regions of interest (ROIs) were extracted from the central, anterior, posterior, superior, and inferior sections. A total of 15 ROIs were extracted from TADs of 15, 20, and 25 mm. The measurement parameters included BMD, percent bone volume: bone volume/total volume (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), structural model index (SMI), and degree of anisotropy (DOA). Results: The lowest BMD and BV/TV values were observed in the inferior region and differed significantly from those in other regions (P<0.05). Lower Tb.Th and Tb.N values were observed in the inferior region compared with those in the central region (P<0.05). The highest SMI value was observed in the inferior region (P<0.05). With TAD of 15 and 20 mm, the DOA values in the inferior region were lower than those in the anterior region (P<0.05). Lower BMD and BV/TV values were observed in the anterior, central, and inferior regions of TAD of 15 mm compared with those in the corresponding regions of TAD of 25 mm (P<0.05). Conclusion: Positioning the lag screw between TAD of 20 to 25 mm and in the inferior region is recommended, and TAD of less than 15 mm is not recommended.
참고문헌 (22)
- Keene GS, "Mortality and morbidity after hip fractures", BMJ, 307, pp.1248~1250 (1993)
- Bojan AJ, "Critical factors in cut-out complication after Gamma Nail treatment of proximal femoral fractures", BMC Musculoskelet Disord, 14, pp.1~ (2013)
- Baumgaertner MR, "The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip", J Bone Joint Surg Am, 77, pp.1058~1064 (1995)
- De Bruijn K, "Reliability of predictors for screw cutout in intertrochanteric hip fractures", J Bone Joint Surg Am, 94, pp.1266~1272 (2012)
- Andruszkow H, "Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures", Int Orthop, 36, pp.2347~2354 (2012)
- Uemura K, "The distribution of bone mineral density in the femoral heads of unstable intertrochanteric fractures", J Orthop Surg(Hong Kong), 26, pp.2309499018778325~ (2018)
- Konya MN, "Numerical optimization of the position in femoral head of proximal locking screws of proximal femoral nail system; biomechanical study", Balkan Med J, 34, pp.425~431 (2017)
- Zhou JQ, "Failure of PFNA : helical blade perforation and tip-apex distance", Injury, 43, pp.1227~1228 (2012)
- Goffin JM, "The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw : a subject-specific finite element study", J Orthop Res, 31, pp.596~600 (2013)
- Kane P, "Is tip apex distance as important as we think? A biomechanical study examining optimal lag screw placement", Clin Orthop Relat Res, 472, pp.2492~2498 (2014)
- Kuzyk PR, "Femoral head lag screw position for cephalomedullary nails : a biomechanical analysis", J Orthop Trauma, 26, pp.414~421 (2012)
- Lee CH, "Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails", J Int Med Res, 46, pp.2128~2140 (2018)
- Ab-Lazid R, "Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density", J Mech Behav Biomed Mater, 40, pp.354~361 (2014)
- Harrigan TP, "Limitations of the continuum assumption in cancellous bone", J Biomech, 21, pp.269~275 (1988)
- Davis TR, "Intertrochanteric femoral fractures. Mechanical failure after internal fixation", J Bone Joint Surg Br, 72, pp.26~31 (1990)
- Kukla C, "The standard Gamma nail : a critical analysis of 1, 000 cases", J Trauma, 51, pp.77~83 (2001)
- Nordin S, "Mechanical failure of Dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur", Med J Malaysia, 56(Suppl D), pp.12~17 (2001)
- Simpson AH, "Sliding hip screws : modes of failure", Injury, 20, pp.227~231 (1989)
- Utrilla AL, "Trochanteric gamma nail and compression hip screw for trochanteric fractures : a randomized, prospective, comparative study in 210elderly patients with a new design of the gamma nail", J Orthop Trauma, 19, pp.229~233 (2005)
- Wolfgang GL, "Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation", Clin Orthop Relat Res, (163), pp.148~158 (1982)
- Hsueh KK, "Risk factors in cutout of sliding hip screw in intertrochanteric fractures : an evaluation of 937 patients", Int Orthop, 34, pp.1273~1276 (2010)
- Jenkins PJ, "A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures", Acta Orthop, 84, pp.453~459 (2013)