상업지역내 건물 사이 공간에 설치된 실외기 주변 열 환경 분석

Thermal Environment Around the Outdoor Unit Installed in the Space between Buildings in the Commercial Area

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기타공학

초록

In commercial areas, outdoor units are typically installed close to one another in the narrow space between buildings due to insufficient regulations. This makes it difficult to ventilate the discharge airflow, which may lead to deterioration of the performance of outdoor units. This study conducted CFD simulation to analyze the thermal environment according to the installation distance of the outdoor unit. The outdoor unit was installed in the space between buildings, and the thermal environment was analyzed by changing installation distance and wind speed. The performance of the outdoor unit was evaluated by measuring the on-coil temperature. The results show that the closer the distance between outdoor units, the higher the condenser on-coil temperature. Also, the on-coil temperature appeared to rise dramatically at lower wind speed.

Abstract

In commercial areas, outdoor units are typically installed close to one another in the narrow space between buildings due to insufficient regulations. This makes it difficult to ventilate the discharge airflow, which may lead to deterioration of the performance of outdoor units. This study conducted CFD simulation to analyze the thermal environment according to the installation distance of the outdoor unit. The outdoor unit was installed in the space between buildings, and the thermal environment was analyzed by changing installation distance and wind speed. The performance of the outdoor unit was evaluated by measuring the on-coil temperature. The results show that the closer the distance between outdoor units, the higher the condenser on-coil temperature. Also, the on-coil temperature appeared to rise dramatically at lower wind speed.

참고문헌 (11)

  1. Chow. T. T., "Placement of Condensing Units of Split-type Air-conditioners at Low-rise Residences", Applied Thermal Engineering, 22, pp.1431~1444 (2002)
  2. Chow. T.T., "Prediction of On-coil Temperature of Condensers Installed at Tall Building Re-entrant", Applied Thermal Engineering, 19, pp.117~132 (1999)
  3. Avara. Abdollah, "Optimum Placement of Condensing Units of Split-type Air-conditioners by Numerical Simulation", Energy and Buildings, 40, pp.1268~1272 (2008)
  4. Duan. R., "Influence of Air-conditioning Outdoor Unit Arrangement Strategy on Energy Consumption", Procedia Engineering, 146, pp.350~358 (2016)
  5. Xue. H., "Prediction of Temperature Rise Near Condensing Units in the Confined Space of a High-rise Building", Building and Environment, 42, pp.2480~2487 (2007)
  6. Nada. S.A., "Performance and Energy Consumptions of Split Type Air Conditioning Units for Different Arrangements of Outdoor Units in Confined Building Shafts", Applied Thermal Engineering, 123, pp.874~890 (2017)
  7. Nada. S.A., "Solutions of Thermal Performance Problems of Installing AC Outdoor Units in Buildings Light Wells Using Mechanical Ventilations", Applied Thermal Engineering, 131, pp.295~310 (2018)
  8. 최석호, "고층 건물의 실외기실에 위치한 응축기 성능분석", 설비공학 논문집, 15(7), pp.6~594 (2003), 대한설비공학회
  9. Choi. S. H., "Effects of Stacked Condensers in a High-rise Apartment Building", Energy, 30, pp.968~981 (2004)
  10. 허현, "시스템 에어컨 실외기 집단 설치 시 에어 가이드가 외부 열적 환경에 미치는 영향", 한국전산유체공학회지, 22(2), pp.21~27 (2017), 한국전산유체공학회[DOI]
  11. Reiter. S., "Validation Process for CFD Simulations of Wind Around Buildings", EUROPEAN BUILT ENVI-RONMENT CAE CONFERENCE (2008)

관련 논문AI추천

이 간행물의 다른 논문 (8건)