내한촉진제를 사용한 모르타르의 동결온도에 관한 실험적 연구

An Experimental Study on the Freezing Temperature of Mortar Using Accelerator for Freezing Resistance

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류과학기술학

초록

Concrete and mortar can be damaged by frost when they are exposed to low temperatures at early ages, and the strength development can be delayed. To prevent an early frost damage, a chemical accelerator for freezing resistance that can reduce the freezing temperature of concrete or mortar is used. In this study, the preventive effect of salt-free and alkali-accelerator for freezing resistance on early frost damage was evaluated. Three types of accelerators for freezing resistance were used in this experiment. Accelerators for freezing resistance of 2ℓ, 4ℓ, and 6ℓ per 100kg cement were used in mortar, and the freezing temperature of mortar was measured. Consequently, mortar that used accelerators for freezing resistance of S Corp, B Corp, and K Corp showed the freezing temperature range of –0.3 to -1.8°C, -0.7 to -1.9°C, and –0.9 to -3.7°C, respectively. Therefore, these accelerators for freezing resistance can be used in slight frost conditions but not in air temperature conditions of below–10°C.

Abstract

Concrete and mortar can be damaged by frost when they are exposed to low temperatures at early ages, and the strength development can be delayed. To prevent an early frost damage, a chemical accelerator for freezing resistance that can reduce the freezing temperature of concrete or mortar is used. In this study, the preventive effect of salt-free and alkali-accelerator for freezing resistance on early frost damage was evaluated. Three types of accelerators for freezing resistance were used in this experiment. Accelerators for freezing resistance of 2ℓ, 4ℓ, and 6ℓ per 100kg cement were used in mortar, and the freezing temperature of mortar was measured. Consequently, mortar that used accelerators for freezing resistance of S Corp, B Corp, and K Corp showed the freezing temperature range of –0.3 to -1.8°C, -0.7 to -1.9°C, and –0.9 to -3.7°C, respectively. Therefore, these accelerators for freezing resistance can be used in slight frost conditions but not in air temperature conditions of below–10°C.

참고문헌 (7)

  1. 대한건축학회, "건설교통부제정 건축공사표준시방서(05025 한중콘크리트)", 263~268 (1999)
  2. 김영진, "내한촉진제를 사용한 한중콘크리트의 실구조물 적용에 관한 연구", 콘크리트학회 논문집, 15(2), pp.254~262 (2003), 한국콘크리트학회
  3. "KS M 2163(자동차용 창유리 세정액)", ~ (2017)
  4. "KS L 5109(수경성 시멘트 반죽 및 모르타르의 기계적 혼합방법)", ~ (2012)
  5. 대한건축학회, "건설교통부제정 건축공사표준시방서(05050 고내구성 콘크리트)", 279~285 (1999)
  6. 한민철, "기온과 콘크리트", pp.59~ (2002), 기문당
  7. 한국콘크리트학회, "콘크리트표준시방서 해설(제14장 한중콘크리트)", 298~311 (2009)