초록

The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.

Abstract

The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.

참고문헌 (14)

  1. SCLee, "Indoor and outdoor air quality investigation at schools in Hong Kong", Chemosphere, 41(1–2), pp.109~113 (2000)
  2. SOBaek, "Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor", outdoor relationships, 1997, pp.31(4), 529~544
  3. 박동원, "실내 공기오염이 천식에 미치는 영향", Allergy Asthma & Respiratory Disease, 5(6), pp.312~319 (2017), 대한 소아알레르기 호흡기학회[DOI]
  4. "Indoor Air Quality Management Law"[URL]
  5. 심인숙, "병원내 공기 중 미생물 분포와 동정에 관한 연구 고찰", 한국실내환경학회지, 5(3), pp.196~214 (2008), 한국실내환경학회
  6. 이보람, "Predicted Mean Vote(PMV)를 이용한 겨울철 종합병원의 실내 온·열 환경의 평가", 한국환경보건학회지, 41(6), pp.389~396 (2015), 한국환경보건학회
  7. 조성연, "치과대학병원 종사자의 실내자각증상 관련요인 분석 -서울시내 소재 치과대학병원을 중심으로-", 환경독성보건학회지, 24(2), pp.149~157 (2009), 환경독성보건학회
  8. A Study on the Recognition and Improvement of Indoor Air Quality in Daejeon Metropolitan Office Space, "HDJeong", DSRI, 3~117 (2017)
  9. 유복희, "공동주택 거주자의 실내공기질 인식에 대한 특성 및 영향 요인", 대한건축학회논문집, 26(01), pp.349~356 (2010), 대한건축학회
  10. 박정하, "보육시설의 실내공기질에 관한 현장측정 및 설문조사 연구", 대한건축학회논문집, 27(03), pp.277~286 (2011), 대한건축학회
  11. 이지은, "보육시설의 PM10, TSP, CO2 농도와 보육교사의 실내 공기질 인식에 관한 연구", 한국학교보건학회지, 23(1), pp.29~40 (2010), 한국학교보건학회
  12. 최유진, "서울시민의 주택 실내공기질 인식과 관리행태에 관한 연구", 서울도시연구, 14(2), pp.131~144 (2013), 서울연구원[DOI]
  13. Ministry of Environment, "Guidelines for the Managem ent of Indoor Air Quality in Elderly Care Facilities", ~ (2018)
  14. DCShin, "Influence of indoor pollution in habitants’ health and development of the model of healthy home environment", Korea Society for Atmospheric Environment, Proceeding of the 35th Meeting of KOSAE, pp.69~70 (2003)

이 간행물의 다른 논문 (28건)