초록
Colorectal cancer has substantial morbidity and mortality. Approximately one-quarter of cases are overlooked during screening colonoscopy, leading to interval colorectal cancer. The use of artificial intelligence (AI) through deep learning systems has demonstrated promising results in the detection of polyps and adenomas. Consequently, our objective was to evaluate the impact of AI on adenoma detection. To identify relevant studies, we searched the PubMed, MEDLINE, and Cochrane Library databases without restrictions on publication date. Ultimately, we analyzed 16 randomized controlled trials involving 13,685 participants. The primary outcome assessed was the effect of AI-assisted colonoscopy (AIAC) on the adenoma detection rate (ADR). Secondary outcomes included the polyp detection rate (PDR) and adenomas per colonoscopy (APC). A random-effects model was used to calculate pooled effect sizes, and statistical heterogeneity was evaluated using the Higgins I2 statistic, with I2 cutoff points of 25%, 50%, and 75% indicating low, moderate, and high heterogeneity, respectively. Publication bias was investigated using a funnel plot, and the quality of evidence was appraised using the Grading of Recommendations, Assessment, Development, and Evaluation framework. The findings indicated a 26% greater ADR with AIAC than with standard colonoscopy (40.4% vs. 31.9%). Additionally, AIAC was associated with a 30% greater PDR (52.9% vs. 40.1%) and a 44% higher APC. The findings demonstrate that the integration of AI in colonoscopy improves ADR, PDR, and APC, potentially reducing the incidence of interval colorectal cancer.
Abstract
Colorectal cancer has substantial morbidity and mortality. Approximately one-quarter of cases are overlooked during screening colonoscopy, leading to interval colorectal cancer. The use of artificial intelligence (AI) through deep learning systems has demonstrated promising results in the detection of polyps and adenomas. Consequently, our objective was to evaluate the impact of AI on adenoma detection. To identify relevant studies, we searched the PubMed, MEDLINE, and Cochrane Library databases without restrictions on publication date. Ultimately, we analyzed 16 randomized controlled trials involving 13,685 participants. The primary outcome assessed was the effect of AI-assisted colonoscopy (AIAC) on the adenoma detection rate (ADR). Secondary outcomes included the polyp detection rate (PDR) and adenomas per colonoscopy (APC). A random-effects model was used to calculate pooled effect sizes, and statistical heterogeneity was evaluated using the Higgins I2 statistic, with I2 cutoff points of 25%, 50%, and 75% indicating low, moderate, and high heterogeneity, respectively. Publication bias was investigated using a funnel plot, and the quality of evidence was appraised using the Grading of Recommendations, Assessment, Development, and Evaluation framework. The findings indicated a 26% greater ADR with AIAC than with standard colonoscopy (40.4% vs. 31.9%). Additionally, AIAC was associated with a 30% greater PDR (52.9% vs. 40.1%) and a 44% higher APC. The findings demonstrate that the integration of AI in colonoscopy improves ADR, PDR, and APC, potentially reducing the incidence of interval colorectal cancer.
참고문헌 (35)
- Sharma R, "Global, regional, and national burden of colorectal cancer and its risk factors, 1990-2019: a systematic analysis for the Global Burden of Disease study 2019", Lancet Gastroenterol Hepatol, 7, pp.627~647 (2022)
- Kanth P, "Screening and prevention of colorectal cancer", BMJ, 374, pp.n1855~ (2021)
- Rutter MD, "World Endoscopy Organization consensus statements on post-colonoscopy and postimaging colorectal cancer", Gastroenterology, 155, pp.909~925 (2018)
- Zhao S, "Magnitude, risk factors, and factors associated with adenoma miss rate of tandem colonoscopy : a systematic review and meta-analysis", Gastroenterology, 156, pp.1661~1674 (2019)
- Corley DA, "Adenoma detection rate and risk of colorectal cancer and death", N Engl J Med, 370, pp.1298~1306 (2014)
- Rex DK, "Quality indicators for colonoscopy", Am J Gastroenterol, 110, pp.72~90 (2015)
- Joseph J, "Artificial intelligence in colonoscopy", World J Gastroenterol, 27, pp.4802~4817 (2021)
- Sinagra E, "Use of artificial intelligence in improving adenoma detection rate during colonoscopy : might both endoscopists and pathologists be further helped", World J Gastroenterol, 26, pp.5911~5918 (2020)
- Areia M, "Cost-effectiveness of artificial intelligence for screening colonoscopy : a modelling study", Lancet Digit Health, 4, pp.e436~e444 (2022)
- Hann A, "Current status and limitations of artificial intelligence in colonoscopy", United European Gastroenterol J, 9, pp.527~533 (2021)
- Page MJ, "The PRISMA 2020 statement : an updated guideline for reporting systematic reviews", BMJ, 372, pp.n71~ (2021)
- Grant J, "Measuring inconsistency in knowledgebases", J Intell Inf Syst, 27, pp.159~184 (2006)
- Granholm A, "Use of the GRADE approach in systematic reviews and guidelines", Br J Anaesth, 123, pp.554~559 (2019)
- Liu WN, "Study on detection rate of polyps and adenomas in artificial-intelligence-aided colonoscopy", Saudi J Gastroenterol, 26, pp.13~19 (2020)
- Liu P, "The singlemonitor trial : an embedded CADe system increased adenoma detection during colonoscopy : a prospective randomized study", Therap Adv Gastroenterol, 13, pp.1756284820979165~ (2020)
- Yao L, "Effect of an artificial intelligence-based quality improvement system on efficacy of a computer-aided detection system in colonoscopy : a four-group parallel study", Endoscopy, 54, pp.757~768 (2022)
- Wang P, "Effect of a deep-learning computer-aided detection system on adenoma detection during colonoscopy(CADe-DB trial) : a double-blind randomised study", Lancet Gastroenterol Hepatol, 5, pp.343~351 (2020)
- Wang P, "Realtime automatic detection system increases colonoscopic polyp and adenoma detection rates : a prospective randomised controlled study", Gut, 68, pp.1813~1819 (2019)
- Wang P, "Artificial intelligence empowers the second-observer strategy for colonoscopy : a randomized clinical trial", Gastroenterol Rep(Oxf), 11, pp.goac081~ (2023)
- Xu H, "Artificial intelligenceassisted colonoscopy for colorectal cancer screening : a multicenter randomized controlled trial", Clin Gastroenterol Hepatol, 21, pp.337~346 (2023)
- Rondonotti E, "Efficacy of a computer-aided detection system in a fecal immunochemical test-based organized colorectal cancer screening program: a randomized controlled trial (AIFIT study)", Endoscopy, 54, pp.1171~1179 (2022)
- Repici A, "Artificial intelligence and colonoscopy experience : lessons from two randomised trials", Gut, 71, pp.757~765 (2022)
- Repici A, "Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial", Gastroenterology, 159, pp.512~520 (2020)
- Ahmad A, "Evaluation of a real-time computer-aided polyp detection system during screening colonoscopy : AI-detect study", Endoscopy, 55, pp.313~319 (2023)
- Glissen Brown JR, "Deep learning computer-aided polyp detection reduces adenoma miss rate : a United States multi-center randomized tandem colonoscopy study(CADeT-CS trial)", Clin Gastroenterol Hepatol, 20, pp.1499~1507 (2022)
- Lachter J, "Novel artificial intelligence-enabled deep learning system to enhance adenoma detection : a prospective randomized controlled study", iGIE, 2, pp.52~58 (2023)
- Aniwan S, "Computer-aided detection, mucosal exposure device, their combination, and standard colonoscopy for adenoma detection : a randomized controlled trial", Gastrointest Endosc, 97, pp.507~516 (2023)
- Vilkoite I, "The role of an artificial intelligence method of improving the diagnosis of neoplasms by colonoscopy", Diagnostics(Basel), 13, pp.701~ (2023)
- Gimeno-García AZ, "Usefulness of a novel computer-aided detection system for colorectal neoplasia : a randomized controlled trial", Gastrointest Endosc, 97, pp.528~536 (2023)
- Rees CJ, "UK key performance indicators and quality assurance standards for colonoscopy", Gut, 65, pp.1923~1929 (2016)
- Wang HS, "Adenoma detection rate is necessary but insufficient for distinguishing high versus low endoscopist performance", Gastrointest Endosc, 77, pp.71~78 (2013)
- Barua I, "Artificial intelligence for polyp detection during colonoscopy : a systematic review and metaanalysis", Endoscopy, 53, pp.277~284 (2021)
- Nazarian S, "Diagnostic accuracy of artifi-cial intelligence and computer-aided diagnosis for the detection and characterization of colorectal polyps : systematic review and meta-analysis", J Med Internet Res, 23, pp.e27370~ (2021)
- Shao L, "Effects of ai-assisted colonoscopy on adenoma miss rate", adenoma detection rate : a protocol for systematic review and metaanalysis, 2022, pp.101, e31945~
- Larsen SLV, "Artificial intelligence in colonoscopy : a review on the current status", DEN Open, 2, pp.e109~ (2022)