Periodic Comparability Verification and Within-Laboratory Harmonization of Clinical Chemistry Laboratory Results at a Large Healthcare Center With Multiple Instruments

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: Results from laboratories using multiple instruments should be standardized or harmonized and comparability-verified for consistent quality control. We developed a simple frequent comparability verification methodology applicable to large healthcare centers using multiple clinical chemistry instruments from different manufacturers. Methods: Comparability of five clinical chemistry instruments (Beckman Coulter AU5800, Abbott Architect Ci16000, two Siemens Vista 1500, and Ortho Vitros 5600) was evaluated from 2015 to 2019 for 12 clinical chemistry measurements. Pooled residual patient samples were used for weekly verifications. Results from any instrument exceeding the allowable verification range versus the results from the comparative instrument (AU5800) were reported to clinicians after being multiplied by conversion factors that were determined via a linear regression equation obtained from simplified comparison. Results: Over the five-year study period, 432 weekly inter-instrument comparability verification results were obtained. Approximately 58% of results were converted due to non-comparable verification. Expected average absolute percent bias and percentage of non-comparable results for non-converted and converted results after conversion action were much lower than those for data measured before conversion action. The inter-instrument CV for both non-converted and converted results after conversion action was much lower than that for measured data before conversion action for all analytes. Conclusions: We maintained within-laboratory comparability of clinical chemistry tests from multiple instruments for five years using frequent low-labor periodic comparability verification methods from pooled residual sera. This methodology is applicable to large testing facilities using multiple instruments.

Abstract

Background: Results from laboratories using multiple instruments should be standardized or harmonized and comparability-verified for consistent quality control. We developed a simple frequent comparability verification methodology applicable to large healthcare centers using multiple clinical chemistry instruments from different manufacturers. Methods: Comparability of five clinical chemistry instruments (Beckman Coulter AU5800, Abbott Architect Ci16000, two Siemens Vista 1500, and Ortho Vitros 5600) was evaluated from 2015 to 2019 for 12 clinical chemistry measurements. Pooled residual patient samples were used for weekly verifications. Results from any instrument exceeding the allowable verification range versus the results from the comparative instrument (AU5800) were reported to clinicians after being multiplied by conversion factors that were determined via a linear regression equation obtained from simplified comparison. Results: Over the five-year study period, 432 weekly inter-instrument comparability verification results were obtained. Approximately 58% of results were converted due to non-comparable verification. Expected average absolute percent bias and percentage of non-comparable results for non-converted and converted results after conversion action were much lower than those for data measured before conversion action. The inter-instrument CV for both non-converted and converted results after conversion action was much lower than that for measured data before conversion action for all analytes. Conclusions: We maintained within-laboratory comparability of clinical chemistry tests from multiple instruments for five years using frequent low-labor periodic comparability verification methods from pooled residual sera. This methodology is applicable to large testing facilities using multiple instruments.

참고문헌 (24)

  1. Miller WG, "Harmonization : its time has come", Clin Chem, 63, pp.1184~1186 (2017)
  2. W. Greg Miller, "Harmonization: the Sample, the Measurement, and the Report", Annals of Laboratory Medicine, 34(3), pp.187~197 (2014), 대한진단검사의학회
  3. Greg Miller W, "Roadmap for harmonization of clinical laboratory measurement procedures", Clin Chem, 57, pp.1108~1117 (2011)
  4. Tate JR, "Harmonization of clinical laboratory test results", EJIFCC, 27, pp.5~14 (2016)
  5. CLSI, "Verification of comparability of patient results within one health care system: approved guideline (interim revision)" (2012), Clinical and Laboratory Standards Institute
  6. Myers GL, "A reference method laboratory network for cholesterol : A model for standardization and improvement of clinical laboratory measurements", Clin Chem, 46, pp.1762~1772 (2000)
  7. Myers GL, "Recommendations for improving serum creatinine measurement : A report from the laboratory working group of the national kidney disease education program", Clin Chem, 52, pp.5~18 (2006)
  8. Vesper HW, "Standardization of testosterone measurements in humans", J Steroid Biochem Mol Biol, 121, pp.513~519 (2010)
  9. Thienpont LM, "Harmonization of serum thyroid-stimulating hormone measurements paves the way for the adoption of a more uniform reference interval", Clin Chem, 63, pp.1248~1260 (2017)
  10. Little RR, "The National Glycohemoglobin Standardization Program : over 20 years of improving hemoglobin A1c measurement", Clin Chem, 65, pp.839~848 (2019)
  11. Lee EJ, "Verification of the comparability of laboratory results from two instruments within one health care system according to Clinical and Laboratory Standard Institute EP31-A-IR", J Lab Med Qual Assur, 38, pp.129~136 (2016)
  12. CLSI, "Measurement procedure comparison and bias estimation using patient samples; Approved guideline-Third edition" (2013), Clinical Laboratory Standards Institute
  13. Kim Sollip, "Schemes and Performance Evaluation Criteria of Korean Association of External Quality Assessment (KEQAS) for Improving Laboratory Testing", Annals of Laboratory Medicine, 41(2), pp.230~239 (2021), 대한진단검사의학회[DOI]
  14. "External Quality Assurance/proficiency testing for international laboratories" (2021)[URL]
  15. Jones GR, ""Allowable limits of performance"for External Quality Assurance programs – an approach to application of the Stockholm criteria by the RCPA Quality Assurance programs", Clin Biochem Rev, 33, pp.133~139 (2012)
  16. Baadenhuijsen H, "A model for harmonization of routine clinical chemistry results between clinical laboratories", Ann Clin Biochem, 37, pp.330~337 (2000)
  17. "International consortium for harmonization of clinical laboratory results (ICHCLR)" (2021)[URL]
  18. Schumann G, "IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase", Clin Chem Lab Med, 40, pp.725~733 (2002)
  19. Schumann G, "IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase", Clin Chem Lab Med, 40, pp.718~724 (2002)
  20. Jansen R, "A category 1 EQA scheme for comparison of laboratory performance and method performance : an international pilot study in the framework of the Calibration 2000 Project", Clin Chim Acta, 432, pp.90~98 (2014)
  21. Jun SH, "Annual report on the external quality assessment scheme for clinical chemistry in Korea(2014)", J Lab Med Qual Assur, 37, pp.115~123 (2015)
  22. 이지수, "Pyridoxal-5′-Phosphate 시약이 아미노전이효소 측정에 미치는 영향", Laboratory Medicine Online, 7(3), pp.128~134 (2017), 대한진단검사의학회
  23. 정태동, "Accuracy-Based Proficiency Testing of Creatinine Measurement: 7 Years’ Experience in Korea", Laboratory Medicine and Quality Assurance, 41(1), pp.13~23 (2019), 대한진단검사정도관리협회[DOI]
  24. Jeong-Ho Kim, "Report of Korean Association of External Quality Assessment Service on the Accuracy-Based Lipid Proficiency Testing (2016-2018)", Laboratory Medicine and Quality Assurance, 41(3), pp.121~129 (2019), 대한진단검사정도관리협회[DOI]

관련 논문AI추천

한 검사실 내에서 사용 중인 두 대의 자동임상화학검사기기 간 결과값의 동등성검증김보현, 차영주대한진단검사의학회 · Laboratory Medicine Online2014 · 제4권 제2호Practical Considerations for Clinical Laboratories in Top-down Approach for Assessing the Measurement Uncertainty of Clinical Chemistry Analytes전사일, Gu Hyunjung, Hong Jinyoung, Lee Juhee, Lee Woochang, Lee Woo-In, Min Won-Ki, Yun Yeo-Min대한진단검사의학회 · Annals of Laboratory Medicine2022 · 제42권 제6호Can Reference Materials Prepared Following CLSI C37-A Be Utilized Without Commutability Assessment? Perspectives Based on Lipid MeasurementsAn Dongheui, Cho Chan-Ik, Choi Qute, Kim Jeong-Ho, Kim Sollip, Kwon Gye Cheol, Lee Sang-Guk, Park Pil-Whan, Seo Jong Do, Song Junghan, Yun Yeo Min대한진단검사의학회 · Annals of Laboratory Medicine2025 · 제45권 제6호Evaluation of Coefficients of Variation for Clinical Chemistry Tests Based on Internal Quality Control Data Across 5,425 Laboratories in China From 2013 to 2022Dong Na, Kang Fengfeng, Liu Jiali, Wang Wei, Wang Zhiguo, Yuan Shuai, Zhang Chuanbao, Zhang Zhixin, Zhao Haijian대한진단검사의학회 · Annals of Laboratory Medicine2024 · 제44권 제3호Hitachi LABOSPECT 008에서의 Wako 및 Sekisui 임상화학시약의 분석성능김명신, 김용구, 박해일, 이제훈, 채효진대한진단검사의학회 · Laboratory Medicine Online2013 · 제3권 제4호검사실 전자동화시스템 정도관리물질 통합운영 경험Hong Soonchul, Lee JaeHo, Lim Yong Kwan, Yoo Byeongpil, Yun Jiwon대한진단검사의학회 · Laboratory Medicine Online2025 · 제15권 제3호

이 간행물의 다른 논문 (20건)