Recently, as the continuously increasing of the one-person households, builders were focusing on a built-in furniture development for efficiency. Through the dead space of the space can be reduced. Also, Condensation that occurs in a built-in furnitures installation space may result in different results depending on the room’s direction, floor, finish, adjacent room effect, occupant’s lifestyle. In this background, it can be considered in terms of functional aspect and morphological aspect by using WUFI2D simulation system. As a result, the tendency of occurrence of condensation was examined by comparing the water content and the growth potential of fungus graph which came from WUFI2D. Results of this study are as followings: Built-in furniture, both top & bottom open, is more stable to condensation than the built-in furniture with the top or bottom open. Also, Among from the top floor built-in furniture to the bottom of it, the bottom one is more stable to condensation.
Abstract
Recently, as the continuously increasing of the one-person households, builders were focusing on a built-in furniture development for efficiency. Through the dead space of the space can be reduced. Also, Condensation that occurs in a built-in furnitures installation space may result in different results depending on the room’s direction, floor, finish, adjacent room effect, occupant’s lifestyle. In this background, it can be considered in terms of functional aspect and morphological aspect by using WUFI2D simulation system. As a result, the tendency of occurrence of condensation was examined by comparing the water content and the growth potential of fungus graph which came from WUFI2D. Results of this study are as followings: Built-in furniture, both top & bottom open, is more stable to condensation than the built-in furniture with the top or bottom open. Also, Among from the top floor built-in furniture to the bottom of it, the bottom one is more stable to condensation.
참고문헌 (14)
- Seong Jin Chang, "Hygrothermal performance improvement of the Korean wood frame walls using macro-packed phase change materials (MPPCM)", Thermal engineering, pp.457~465 (2017)
- Filip Fedorik, "HAM and mould growth analysis of a wooden wall", International Journal of Sustainable Built Environment, 2(1), pp.19~26 (2012)
- 유슬기, "Comparison of Hygrothermal Performance between Wood and Concrete Wall Structures using Simulation Program", 목재공학, 44(2), pp.283~293 (2016), 한국목재공학회
- Hyun-Hwa Lee, "Evaluation of the thermal environment for condensation and mold problem diagnosis around built-in furniture in Korean apartment buildings during summer and winter", Energy Procedia, pp.601~612 (2016)
- ASHRAE, "ASHRAE HANDBOOK. Fundamentals" (2005)
- 강유진, "실내외 기후 조건에 따른 목조 벽체의 열⋅습기 성능 평가", 대한건축학회 학술발표대회 논문집, pp.281~282 (2016)
- 강유진, "WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가", 목재공학, 44(1), pp.75~84 (2016), 한국목재공학회
- 김다영, "소형공동주택 모델하우스에 나타난 붙박이가구의 계획특성", 한국생활과학회 학술대회 논문집, pp.202~203 (2012)
- 이가경, "공동주택 안목치수 설계기준에 의한 붙박이장의 표준화방안 연구", 한국주거학회논문집, 21(6), pp.53~60 (2010), 한국주거학회
- 오혜린, "기존 공동주택 붙박이장에서 보조난방장치 설치조건에 따른 표면 결로 방지 성능 평가", 대한건축학회 학술발표대회 논문집, pp.517~518 (2016)
- 이현화, "공동주택의 붙박이장 설치 공간에서 결로 발생 현상 진단을 위한 동계 실내 온열 환경 평가", 대한건축학회논문집, 32(7), pp.131~140 (2016), 대한건축학회[DOI]
- 이승용, "붙박이장의 형태, 구조 변화와 소비자 특성 연구", 한국콘텐츠학회 논문지, 8(3), pp.146~155 (2008), 한국콘텐츠학회
- 장성진, "국내 농어촌 표준 목조주택의 hygrothermal 성능 분석", 목재공학, 44(3), pp.440~448 (2016), 한국목재공학회