Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: Radiographic examinations are frequently performed for diagnostic and therapeutic purposes in neonatal intensive care units (NICUs). However, concerns are emerging regarding the safety of radiation exposure, especially in vulnerable preterm infants in periods of rapid cellular division. This quality improvement (QI) project aimed to reduce radiation hazards in level-IV NICU. Methods: We established an "X-ray prescription protocol" and educated the physicians to ensure that only essential radiographs were obtained. Additionally, we discouraged full-body infantograms and emphasized the prescription of targeted radiographs, such as chest or abdominal radiographs. Furthermore, to reduce the dose-area product (DAP, Gy·cm2) values, which act as a surrogate for radiation exposure, we provided training to radiologic technologists on meticulous collimation for each radiography session. We aimed to achieve a 30% reduction in the average monthly cumulative DAP per patient, which was calculated by dividing the total monthly DAP from radiographs in the NICU by the monthly average of patient admissions. Retrospective baseline data were collected 8 months pre-intervention and prospectively for 4 months post-interventions. Results: The average monthly X-ray count per patient was 28.3 in the pre-intervention period (October 2022 to May 2023), which decreased to 25.4 in the post-intervention period (June 2023 to September 2023), reflecting a 10.2% reduction (P=0.109). The average monthly infantogram count per patient showed an 18.0% reduction (25.9% to 21.2%, P=0.016), and the proportion of infantograms in the total X-ray counts decreased from 91.5% to 83.3% (P=0.017). The DAP value per X-ray decreased by 42.6%, from an average of 0.25 to 0.14 (P=0.011). The primary outcome, the average monthly cumulative DAP value per patient, showed a substantial reduction of 48.6%, dropping from 7.00 to 3.60 (P=0.004). The baseline characteristics and short-term morbidities of the patients did not differ significantly between the pre- and post-intervention period. Conclusion: Our QI approach, which included discouraging excessive prescriptions of infantograms and promoting optimal collimation, significantly reduced the average monthly radiation exposure in the NICU, benefiting both patients and healthcare workers.
Abstract
Purpose: Radiographic examinations are frequently performed for diagnostic and therapeutic purposes in neonatal intensive care units (NICUs). However, concerns are emerging regarding the safety of radiation exposure, especially in vulnerable preterm infants in periods of rapid cellular division. This quality improvement (QI) project aimed to reduce radiation hazards in level-IV NICU. Methods: We established an "X-ray prescription protocol" and educated the physicians to ensure that only essential radiographs were obtained. Additionally, we discouraged full-body infantograms and emphasized the prescription of targeted radiographs, such as chest or abdominal radiographs. Furthermore, to reduce the dose-area product (DAP, Gy·cm2) values, which act as a surrogate for radiation exposure, we provided training to radiologic technologists on meticulous collimation for each radiography session. We aimed to achieve a 30% reduction in the average monthly cumulative DAP per patient, which was calculated by dividing the total monthly DAP from radiographs in the NICU by the monthly average of patient admissions. Retrospective baseline data were collected 8 months pre-intervention and prospectively for 4 months post-interventions. Results: The average monthly X-ray count per patient was 28.3 in the pre-intervention period (October 2022 to May 2023), which decreased to 25.4 in the post-intervention period (June 2023 to September 2023), reflecting a 10.2% reduction (P=0.109). The average monthly infantogram count per patient showed an 18.0% reduction (25.9% to 21.2%, P=0.016), and the proportion of infantograms in the total X-ray counts decreased from 91.5% to 83.3% (P=0.017). The DAP value per X-ray decreased by 42.6%, from an average of 0.25 to 0.14 (P=0.011). The primary outcome, the average monthly cumulative DAP value per patient, showed a substantial reduction of 48.6%, dropping from 7.00 to 3.60 (P=0.004). The baseline characteristics and short-term morbidities of the patients did not differ significantly between the pre- and post-intervention period. Conclusion: Our QI approach, which included discouraging excessive prescriptions of infantograms and promoting optimal collimation, significantly reduced the average monthly radiation exposure in the NICU, benefiting both patients and healthcare workers.
참고문헌 (22)
- Soboleski D, "Unnecessary irradiation to non-thoracic structures during pediatric chest radiography", Pediatr Radiol, 36, pp.22~25 (2006)
- Iyer NP, "Radiation exposure in extremely low birth weight infants during their neonatal intensive care unit stay", World J Pediatr, 9, pp.175~178 (2013)
- Bader D, "Unintentional exposure of neonates to conventional radiography in the neonatal intensive care units", J Perinatol, 27, pp.579~585 (2007)
- Pearce MS, "Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours : a retrospective cohort study", Lancet, 380, pp.499~505 (2012)
- Valentin J, "Low-dose extrapolation of radiation-related cancer risk", Ann ICRP, 35, pp.1~140 (2005)
- Wallingford K, "Development and evaluation of a radiation safety program in the NICU", Neonatal Netw, 36, pp.306~312 (2017)
- Paquette K, "Cancer risk in children and young adults born preterm : a systematic review and meta-analysis", PLoS One, 14, pp.e0210366~ (2019)
- Seppala LK, "Preterm birth, neonatal therapies and the risk of childhood cancer", Int J Cancer, 148, pp.2139~2147 (2021)
- Gislason-Lee AJ, "Patient X-ray exposure and ALARA in the neonatal intensive care unit : global patterns", Pediatr Neonatol, 62, pp.3~10 (2021)
- Dabin J, "Radiation dose to premature new-borns in the Belgian neonatal intensive care units", Radiat Prot Dosimetry, 158, pp.28~35 (2014)
- Stollfuss J, "A comparative study of collimation in bedside chest radiography for preterm infants in two teaching hospitals", Eur J Radiol Open, 2, pp.118~122 (2015)
- Morrison G, "Pediatric digital radiography education for radiologic technologists : current state", Pediatr Radiol, 41, pp.602~610 (2011)
- Hlabangana LT, "Short-term impact of pictorial posters and a crash course on radiographic errors for improving the quality of paediatric chest radiographs in an unsupervised unit : a pilot study for quality-assurance outreach", Pediatr Radiol, 45, pp.158~165 (2015)
- "European guidelines on diagnostic reference levels for paediatric imaging" (2018)[URL]
- "Diagnostic reference levels: guidance on the establishment, use and review of diagnostic reference levels for medical exposure to ionising radiation" (2023)[URL]
- Gilley R, "Establishing weight-based diagnostic reference levels for neonatal chest X-rays", Radiography(Lond), 29, pp.812~817 (2023)
- Olgar T, "Radiation exposure to premature infants in a neonatal intensive care unit in Turkey", Korean J Radiol, 9, pp.416~419 (2008)
- Zhang X, "Quality control of bedside DR in neonatal chest radiography using a chest stabilization device and its clinical application", BMC Pediatr, 20, pp.345~ (2020)
- Jaeel P, "Ultrasonography for endotracheal tube position in infants and children", Eur J Pediatr, 176, pp.293~300 (2017)
- Shabeer MP, "Bedside sonography performed by neonatology residents to confirm central vascular catheter position in neonates : a prospective diagnostic evaluation study", J Neonatal Perinatal Med, 14, pp.101~107 (2021)
- D’Andrea V, "Umbilical venous catheter update : a narrative review including ultrasound and training", Front Pediatr, 9, pp.774705~ (2022)
- Yu CC, "Radiation safety in the neonatal intensive care unit : too little or too much concern?", Pediatr Neonatol, 51, pp.311~319 (2010)
