논문KCI 등재
하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화
1
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
참고문헌 (35)
- "The long-term efficacy of cur-rently used dental implants:A reviewand proposed criteria of success", 1, pp.11~25 (1986)
- "A long-term follow-upstudy of osseointegrated implants in thetreatment of totally edentulous jaws", 4, pp.347~59 (1990)
- "A 15-year study of osseointegrated im-plants in the treatment of the edentulousjaw", 10, pp.387~416 (1981)
- "Critical review of immediate im-plant loading", 14, pp.515~527 (2003)
- "Single-stagesurgery for rehabilitation of the edentulousmandible:Preliminary results", 6, pp.15~22 (1994)
- "Immediate functional load-ing of Branemark den tal implants. An 18-month clinical follow-up study", 10, pp.8~15 (1999)
- "Immediate occlusal loading of Osseotitieimplants in the lower edentulous jaw. Amulticenter prospective study", 15, pp.278~284 (2004)
- "Timing of loadingand effect of micromotion on bone-dentalimplant interface: Review of experimentalliterature", 43, pp.192~203 (1998)
- "An evaluation ofthe primary implant stability and theimmediate load-bearing capacity accord-ing to the change of cortical bone thickness", 43, pp.248~257 (2005)
- "On functional strain in fixedmandibular reconstructions An in vi-vo study", pp.269~76
- "On functional strain in fixedmandibular reconstructions", pp.241~9
- "Immediate loading of bilaterally spli-nted titanium root-form implants in fixedprosthod- ontics - a technique reexamined:two case reports", 15, pp.344~361 (1995)
- "Immediateloading of threaded implants at stage 1surgery in edentulous arches: Ten con-secutive case reports with 1-to 5-yeardata", 12, pp.319~324 (1997)
- "Assessment of implant stabilityas a prognostic determinant", 11, pp.491~501 (1998)
- "Quantitative determination of the sta-bility of the implant-tissue interface usingresonance frequency analysis", 7, pp.261~267 (1996)
- "Correlation assessment between res-onance frequency analysis and radiogra-phic method according to peri-implantbone change", 43, pp.736~744 (2005)
- "A comparative analysis withresonance frequency according to vari-ous simulated bone defects", 43, pp.487~497 (2005)
- "Resonance frequency analysis ofimplants subjected to immediate or earlyfunctional occlusal loading. Successful vs.failing implants", 15, pp.428~434 (2004)
- "Osseointegration in clinical dentistry", Bra nemark PI
- "Fabri-cation of a screw-retained, implantsup-ported, provisional prosthesis: A clinicalreport", 91, pp.409~413 (2004)
- "A qualitativeand quantitative method for evaluating im-plant success: A 5-year retrospectiveanalysis of the Bra nemark implant", 12, pp.504~514 (1997)
- "Aprospective 15-year follow- up study ofmandibular fixed prostheses supportedby osseointegrat ed implants. Clinical re-sults and marginal bone loss", 7, pp.329~336 (1996)
- "Marginal bone reaction to oral implants:a prospective com parative study of AstraTech and Bra nemark System implants", 13, pp.30~37 (2002)
- "Resonance frequen cy analy-sis measurements of implants at placementsurgery", 19, pp.77~83 (2006)
- "Predicting os-seointegration by measn of implant primarystability. A resonance-frequency analysisstudy with delayed and immediately loadedITI SLA implants", 15, pp.520~528 (2004)
- "Analysis of strain at selected bone sites ofa cantilevered implant-supported pros-thesis", 76, pp.158~164 (1996)
- "Finite elementanalysis of the effect of can- tilever and im-plant length on stress distribution in animplant- supported fixed prosthesis", 76, pp.165~169 (1997)
- "Theoretical cantilever lengths versus clin-ical variables in fifty-five clinical cases", 83, pp.332~343 (2000)
- "Implant-support-ed fixed cantilever prostheses in partial-ly edentulous arches. A seven-year prospec-tive study", 14, pp.303~311 (2003)
- "Mandibularflexure in opening and closing movement", 30, pp.134~8 (1973)
- "Mandibular di-mensional change", 31, pp.482~5 (1974)
- "Mandibular flexure as-sociated with muscle force applied in theretruded axis position", 8, pp.209~21
- "The rotational aspect ofmandibular flexure", 64, pp.483~5 (1990)
- "The influence of fixedsplints on mandibular flexure", 35, pp.643~7 (1976)
- "Man dibular flexure and stressbuild-up in mandibular full-arch fixedprostheses supported by osseointegratedimplants", 14, pp.103~114 (2003)
관련 논문AI추천
무치악 환자에서 하악 임플랜트 지지 피개의치에 의한 즉시 하중 부담에 관한 연구백진, 권긍록, 김장욱, 김형섭대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제1호임프란트의 안정성 높이기 -즉시하중의 안정성 높이기-권종진대한치과의사협회 · 대한치과의사협회지2008 · 제46권 제1호임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향김석규, 박성화, 오갑용대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제1호치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가박찬진, 이양진, 조리라대한치과보철학회 · 대한치과보철학회지2005 · 제43권 제2호하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향김진열, 전영찬, 정창모대한치과보철학회 · 대한치과보철학회지2002 · 제40권 제5호임플란트의 즉시 기능에 관한 최신 지견김윤상대한턱관절교합학회 · 구강회복응용과학지2005 · 제21권 제2호
이 간행물의 다른 논문 (10건)
레진과 치과용 도재의 접착김선재, 이근우, 한종현pp. 159-168타이타늄의 표면개질에 따른 도재 결합 특성임현필, 양홍서, 방몽숙, 이경구, 오계정, 박하옥, 최택휴, 김현승, 박상원, 이광민pp. 169-181타이타늄의 표면거칠기가 도재의 결합강도에 미치는 영향임현필, 박상원, 김상훈, 박하옥, 오계정, 방몽숙, 양홍서pp. 182-190도재라미네이트 접착용 레진시멘트의 색조 안정성에 관한 연구박하옥, 김영운, 박상원, 양홍서, 방몽숙pp. 191-202타이타늄 표면 코팅 처리에 따른 타이타늄도재관의 파절강도 비교이경구, 방몽숙, 양홍서, 임현필, 이광민, 박상원, 김현승, 오계정, 박하옥, 김지혜pp. 203-215
