Radiographic and Clinical Outcomes of Robot-Assisted Posterior Pedicle Screw Fixation: Two-Year Results from a Randomized Controlled Trial
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Purpose: We prospectively assessed the early radiographic and clinical outcomes (minimum follow-up of 2 years) of robot-assistedpedicle screw fixation (Robot-PSF) and conventional freehand pedicle screw fixation (Conv-PSF). Materials and Methods: Patients were randomly assigned to Robot-PSF (37 patients) or Conv-PSF (41 patients) for posterior interbodyfusion surgery. The Robot-PSF group underwent minimally invasive pedicle screw fixation using a pre-planned robotguidedscrew trajectory. The Conv-PSF underwent screw fixation using the freehand technique. Radiographic adjacent segmentdegeneration (ASD) was measured on plain radiographs, and clinical outcomes were measured using visual analogue scale (VAS)and Oswestry disability index (ODI) scores regularly after surgery. Results: The two groups had similar values for radiographic ASD, including University California at Los Angeles grade, vertebraltranslation, angular motion, and loss of disc height (p=0.320). At final follow-up, both groups had experienced significant improvementsin back VAS, leg VAS, and ODI scores after surgery (p<0.001), although inter-group differences were not significantfor back VAS (p=0.876), leg VAS (p=0.429), and ODI scores (p=0.952). In the Conv-PSF group, revision surgery was required fortwo of the 25 patients (8%), compared to no patients in the Robot-PSF group. Conclusion: There were no significant differences in radiographic ASD and clinical outcomes between Robot-PSF and Conv-PSF. Thus, the advantages of robot-assisted surgery (accurate pedicle screw insertion and minimal facet joint violation) do not appearto be clinically significant.
Abstract
Purpose: We prospectively assessed the early radiographic and clinical outcomes (minimum follow-up of 2 years) of robot-assistedpedicle screw fixation (Robot-PSF) and conventional freehand pedicle screw fixation (Conv-PSF). Materials and Methods: Patients were randomly assigned to Robot-PSF (37 patients) or Conv-PSF (41 patients) for posterior interbodyfusion surgery. The Robot-PSF group underwent minimally invasive pedicle screw fixation using a pre-planned robotguidedscrew trajectory. The Conv-PSF underwent screw fixation using the freehand technique. Radiographic adjacent segmentdegeneration (ASD) was measured on plain radiographs, and clinical outcomes were measured using visual analogue scale (VAS)and Oswestry disability index (ODI) scores regularly after surgery. Results: The two groups had similar values for radiographic ASD, including University California at Los Angeles grade, vertebraltranslation, angular motion, and loss of disc height (p=0.320). At final follow-up, both groups had experienced significant improvementsin back VAS, leg VAS, and ODI scores after surgery (p<0.001), although inter-group differences were not significantfor back VAS (p=0.876), leg VAS (p=0.429), and ODI scores (p=0.952). In the Conv-PSF group, revision surgery was required fortwo of the 25 patients (8%), compared to no patients in the Robot-PSF group. Conclusion: There were no significant differences in radiographic ASD and clinical outcomes between Robot-PSF and Conv-PSF. Thus, the advantages of robot-assisted surgery (accurate pedicle screw insertion and minimal facet joint violation) do not appearto be clinically significant.
참고문헌 (27)
- Molliqaj G, "Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery", Neurosurg Focus, 42, pp.E14~ (2017)
- Lonjon N, "Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis", Eur Spine J, 25, pp.947~955 (2016)[DOI]
- Kuo KL, "Assessing the intraoperative accuracy of pedicle screw placement by using a bone-mounted miniature robot system through secondary registration", PLoS One, 11, pp.e0153235~ (2016)[DOI]
- Schatlo B, "Safety and accuracy of robot-assisted versus fluoroscopy guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison", J Neurosurg Spine, 20, pp.636~643 (2014)[DOI]
- Hu X, "Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients", Eur Spine J, 22, pp.661~666 (2013)[DOI]
- Devito DP, "Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study", Spine (Phila Pa 1976), 35, pp.2109~2115 (2010)[DOI]
- Ringel F, "Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation", Spine (Phila Pa 1976), 37, pp.E496~E501 (2012)[DOI]
- Liu H, "Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis", Int J Comput Assist Radiol Surg, 11, pp.2273~2281 (2016)[DOI]
- Kim HJ, "A prospective, randomized, controlled trial of robot-assisted vs freehand pedicle screw fixation in spine surgery", Int J Med Robot, 13, pp.e1779~ (2017)[DOI]
- Kim HJ, "Biomechanical advantages of robot-assisted pedicle screw fixation in posterior lumbar interbody fusion compared with freehand technique in a prospective randomized controlled trial-perspective for patient-specific finite element analysis", Spine J, 17, pp.671~680 (2017)[DOI]
- Holly LT, "Minimally invasive transforaminal lumbar interbody fusion: indications, technique, and complications", Neurosurg Focus, 20, pp.E6~ (2006)
- Kim HJ, "Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test", Spine (Phila Pa 1976), 40, pp.87~94 (2015)[DOI]
- Weinstein JN, "Anatomic and technical considerations of pedicle screw fixation", Clin Orthop Relat Res, 284, pp.34~46 (1992)
- Pfirrmann CW, "Magnetic resonance classification of lumbar intervertebral disc degeneration", Spine (Phila Pa 1976), 26, pp.1873~1878 (2001)[DOI]
- Ghiselli G, "Adjacent segment degeneration in the lumbar spine", J Bone Joint Surg Am, 86-A, pp.1497~1503 (2004)
- Ghiselli G, "L5-S1 segment survivorship and clinical outcome analysis after L4-L5 isolated fusion", Spine (Phila Pa 1976), 28, pp.1275~1280 (2003)
- Miyakoshi N, "Anterior decompression with single segmental spinal interbody fusion for lumbar burst fracture", Spine (Phila Pa 1976), 24, pp.67~73 (1999)[DOI]
- Lee DY, "Single-level instrumented mini-open transforaminal lumbar interbody fusion in elderly patients", J Neurosurg Spine, 9, pp.137~144 (2008)[DOI]
- Cheh G, "Adjacent segment disease following lumbar", thoracolumbar fusion with pedicle screw instrumentation: a minimum 5-year follow-up, 2007, pp.32, 2253~2257
- Fairbank JC, "The Oswestry Disability Index", Spine (Phila Pa 1976), 25, pp.2940~2952 (2000)[DOI]
- Babu R, "Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement", Neurosurgery, 71, pp.962~970 (2012)[DOI]
- Park Y, "Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion", Spine J, 11, pp.295~302 (2011)[DOI]
- Radcliff KE, "What is the rate of lumbar adjacent segment disease after percutaneous versus open fusion?", Orthop Surg, 6, pp.118~120 (2014)[DOI]
- Kanamori M, "Minimum 10-year follow-up study of anterior lumbar interbody fusion for degenerative spondylolisthesis: progressive pattern of the adjacent disc degeneration", Asian Spine J, 6, pp.105~114 (2012)[DOI]
- Soh J, "Analysis of risk factors for adjacent segment degeneration occurring more than 5 years after fusion with pedicle screw fixation for degenerative lumbar spine", Asian Spine J, 7, pp.273~281 (2013)[DOI]
- Gunti Ranga Srinivas, "Adjacent Disc Stress Following Floating Lumbar Spine Fusion: A Finite Element Study", Asian Spine Journal, 11(4), pp.538~547 (2017), 대한척추외과학회
- Kim HJ, "The influence of intrinsic disc degeneration of the adjacent segments on its stress distribution after one-level lumbar fusion", Eur Spine J, 24, pp.827~837 (2015)[DOI]
