흡수성 봉합사를 이용한 무지외반증 Akin 절골술
Fixation with Absorbable Suture Material in Akin Osteotomy
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: The Akin osteotomy which is a closing wedge osteotomy of the proximal phalanx widely used for the correction of hallux valgus has several methods of fixation. we tried to report the effects of the fixation using an absorbable suture material during the Akin osteotomy for the hallux valgus. Materials and Methods: This study was based on 448 cases of 346 patients who were able for follow-up more than 12 months among the patients who had an Akin osteotomy together with the surgery of hallux valgus between March of 2006 and May of 2010. Absorbable suture material had been used in all cases. Radiologically displacement and union of osteotomy site were observed after the surgery, and clinically postoperative complication such as skin irritation, pain and satisfaction were investigated. Results: Radiologically all cases had showed complete union and no case had the loss of an correction due to loss of fixation. Also,any case had no skin irritation due to a knot. Three cases had a medial cortical breakage due to a strong knot, and the initial one case among them had additionally fixed the osteotomy site for four weeks using K-wire, and the remaining two cases had fixed a suture on an articular surface without any fixation of an additional wire. If a medial cortical bone was lost by carrying out an ostectomy due to proximal protrusion of proximal phalanx, three cases could show union through the fixation of suture on an articular surface. Conclusion: This study considers that the fixation of the osteotomy site using an absorbable suture material in an Akin osteotomy was effective method and the advantage of this procedure was unnecessity of the material removal and no skin irritation.
Abstract
Purpose: The Akin osteotomy which is a closing wedge osteotomy of the proximal phalanx widely used for the correction of hallux valgus has several methods of fixation. we tried to report the effects of the fixation using an absorbable suture material during the Akin osteotomy for the hallux valgus. Materials and Methods: This study was based on 448 cases of 346 patients who were able for follow-up more than 12 months among the patients who had an Akin osteotomy together with the surgery of hallux valgus between March of 2006 and May of 2010. Absorbable suture material had been used in all cases. Radiologically displacement and union of osteotomy site were observed after the surgery, and clinically postoperative complication such as skin irritation, pain and satisfaction were investigated. Results: Radiologically all cases had showed complete union and no case had the loss of an correction due to loss of fixation. Also,any case had no skin irritation due to a knot. Three cases had a medial cortical breakage due to a strong knot, and the initial one case among them had additionally fixed the osteotomy site for four weeks using K-wire, and the remaining two cases had fixed a suture on an articular surface without any fixation of an additional wire. If a medial cortical bone was lost by carrying out an ostectomy due to proximal protrusion of proximal phalanx, three cases could show union through the fixation of suture on an articular surface. Conclusion: This study considers that the fixation of the osteotomy site using an absorbable suture material in an Akin osteotomy was effective method and the advantage of this procedure was unnecessity of the material removal and no skin irritation.
참고문헌 (15)
- Young KW, "Fixation with suture material in Akin osteotomy", J Korean Foot Ankle Soc, 8, pp.138~141 (2004)
- Silberman FS, "Proximal phalangeal osteotomy for the correction of hallux valgus", Clin Orthop Relat Res, 85, pp.98~100 (1972)
- Donahue WE, "The proximal phalangeal osteotomy. A technically advanced approach", Clin Podiatry, 2, pp.449~455 (1985)
- Tollison ME, "Combination chevron plus Akin osteotomy for hallux valgus: should age be a limiting factor", Foot Ankle Int, 18, pp.477~481 (1997)
- Green AH, "Akin osteotomy of the hallux proximal phalanx utilizing Richards mini staple fixation", J Foot Surg, 25, pp.386~389 (1986)
- Hayes MW, "Osteotomy of the proximal phalanx with lag screw fixation", J Am Podiatr Med Assoc, 78, pp.41~43 (1988)
- Levitsky DR, "Rigid compression screw fixation of first proximal phalanx osteotomy for hallux abducto valgus", J Foot Surg, 21, pp.65~69 (1982)
- Melamed E, "Technique tip: suture fixation of wedge osteotomies in the foot", Foot Ankle Int, 26, pp.1096~1098 (2005)
- Springer KR, "The role of the akin osteotomy in the surgical management of hallux abducto valgus", Clin Podiatr Med Surg, 6, pp.115~131 (1989)
- Barouk LS, "Forefoot reconstruction", pp.19~73 (2005), Springer-Verlag
- 문기혁, "무지의 회내 변형을 동반한 무지 외반증에서 폐쇄적 회외감염 Akin 절골술의 효과", 대한족부족관절학회지, 12(1), pp.14~19 (2008), 대한족부족관절학회
- Lauf E, "Akin osteotomy of the hallux proximal phalanx utilizing Richards mini staple fixation", J Foot Surg, 26, pp.178~ (1987)
- McGarvey SR, "Internal fixation of the akin osteotomy", Foot Ankle Int, 16, pp.172~173 (1995)
- Barca F, "Resorbable poly-L-lactic acid mini-staples for the fixation of Akin osteotomies", J Foot Ankle Surg, 36, pp.106~111 (1997)
- Murphy JS, "J-wire technique for fixation of the Akin osteotomy", J Am Podiatr Med Assoc, 79, pp.291~293 (1989)