증기양생 조건에 따른 터널 PC 패널의 물리적 특성에 관한 연구
The study on mechanical properties of PC panel with steam curing condition
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
problems exist in the current cast in place concrete lining used in domestic tunnel construction. Especially, the crack of tunnel lining brings about a social and economic problem. It has a lot of influence on stability of structure and the fine finish of lining. So enormous repair-work and reinforcement of tunnel lining could occur an running out of government’s budget. In our country, there are domestic production enterprises which produce a special pre-cast concrete product, but the technical level of them is still far behind compared to developed countries. Also, optimum steam curing method is important for the production of high quality product. But there is no regulation of steam curing method in our country. This study is to investigate the properties of PC panel according to the variation of steam curing conditions such as presteaming time and rate of temperature rise. The result shows that the optimum presteaming time of steam curing method in PC panel is more than 1 hour and the desirable rate of temperature in curing chamber is about 20℃/hr.
Abstract
problems exist in the current cast in place concrete lining used in domestic tunnel construction. Especially, the crack of tunnel lining brings about a social and economic problem. It has a lot of influence on stability of structure and the fine finish of lining. So enormous repair-work and reinforcement of tunnel lining could occur an running out of government’s budget. In our country, there are domestic production enterprises which produce a special pre-cast concrete product, but the technical level of them is still far behind compared to developed countries. Also, optimum steam curing method is important for the production of high quality product. But there is no regulation of steam curing method in our country. This study is to investigate the properties of PC panel according to the variation of steam curing conditions such as presteaming time and rate of temperature rise. The result shows that the optimum presteaming time of steam curing method in PC panel is more than 1 hour and the desirable rate of temperature in curing chamber is about 20℃/hr.
참고문헌 (10)
- 고경택, "양생온도에 따른 콘크리트 특성", 한국콘크리트학회지, 171, pp.22~27 (2005)
- 심종성, "증기양생한 플라이애쉬 혼입 재생골재 콘크리트의 강도특성에 관한 실험적 연구", 한국콘크리트학회 논문집, 15(2), pp.326~329 (2003)
- 이웅종, "증기양생 온도조건에 따른 조강시멘트 콘크리트의 강도발현특성 및 내염특성", 한국콘크리트학회 논문집, 17(2), pp.599~602 (2005)
- 한민철, "양생온도 변화에 따른 시멘트 모르터의 강도발현 성상에 관한 연구", 한국콘크리트학회 논문집, 9(1), pp.3~9 (1997)
- 한상훈, "콘크리트의 재료역학적 성질에 대한 양생온도와 재령의 효과", 한국콘크리트학회 논문집, 12(6), pp.23~34 (2000)
- Saul, A.G.A, "Principles underlying the steam curing of concrete at atmospheric pressure", pp.1955, Cement Concrete Association, Tech. Rep. TRA
- ACI Committee 517, "Recommended practice for atmospheric pressure steam curing of concrete", Journal ACI, 66, pp.629~646 (1969)
- Verbeck, G.J., "Structures and physical properties of cement paste", Proc. 5th Int. Symp. on the Chemistry of Cement (1968)
- Hanson,J.A, "Optimum steam curing procedures for structural lightweight concrete", Journal ACI, 62, pp.661~672 (1965)
- "ASTM C 1202 Standard test method for electrical indication of concrete’s ability to resist chloride ion penetration", ~