Piriformis Muscle: Clinical Anatomy with Computed Tomography in Korean Population
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Backgroud:The objective was to evaluate the distance from the skin and the diameter of the piriformis muscle and their relationship to the body mass index (BMI). Methods:The study was a prospective study involving 60 patients. Patients were prepared on a radiological table in the prone position. Several images were obtained of each. In this view, the distance between the subcutaneous tissue and the piriformis muscle, and the diameter of the piriformis, were measured at three points (medially to laterally). Results:The distance to the piriformis from the skin was 6.6 ± 0.9 cm, 6.3 ± 0.8 cm, and 5.2 ± 0.9 cm in terms of the lateral, center, and medial measurement, respectively. The center of the piriformis had a greater diameter with 1.7 ± 0.4 (0.9−2.5) cm. The distance to the piriformis increased with BMI. Conclusions:This study shows that the lateral of the piriformis muscle has a relatively greater distance from the skin. The center of the piriformis showed a greater diameter than other two portions. We found that the distance of the piriformis from subcutaneous tissues was correlated with BMI, but the diameter of the piriformis was not affected by BMI. These measurements can be used as a reference for determining the piriformis injection site in patients with piriformis syndrome.
Abstract
Backgroud:The objective was to evaluate the distance from the skin and the diameter of the piriformis muscle and their relationship to the body mass index (BMI). Methods:The study was a prospective study involving 60 patients. Patients were prepared on a radiological table in the prone position. Several images were obtained of each. In this view, the distance between the subcutaneous tissue and the piriformis muscle, and the diameter of the piriformis, were measured at three points (medially to laterally). Results:The distance to the piriformis from the skin was 6.6 ± 0.9 cm, 6.3 ± 0.8 cm, and 5.2 ± 0.9 cm in terms of the lateral, center, and medial measurement, respectively. The center of the piriformis had a greater diameter with 1.7 ± 0.4 (0.9−2.5) cm. The distance to the piriformis increased with BMI. Conclusions:This study shows that the lateral of the piriformis muscle has a relatively greater distance from the skin. The center of the piriformis showed a greater diameter than other two portions. We found that the distance of the piriformis from subcutaneous tissues was correlated with BMI, but the diameter of the piriformis was not affected by BMI. These measurements can be used as a reference for determining the piriformis injection site in patients with piriformis syndrome.
참고문헌 (19)
- Ozaki S, "Piriformis syndrome resulting from an anomalous relationship between the sciatic nerve and piriformis muscle", Orthopedics, 22, pp.771~772 (1999)
- Hallin RP, "Sciatic pain and the piriformis muscle", Postgrad Med, 74, pp.69~72 (1983)
- Parziale JR, "The piriformis syndrome", Am J Orthop, 25, pp.819~823 (1996)
- Pace JB, "Piriform syndrome", West J Med, 124, pp.435~439 (1976)
- Chen WS, "Bipartite piriformis muscle: an unusual cause of sciatic nerve entrapment", Pain, 58, pp.269~272 (1994)
- Sayson SC, "Sciatic entrapment neuropathy associated with an anomalous piriformis muscle", Pain, 59, pp.149~152 (1994)
- Sang Yoon Jeon, "Post-radiation Piriformis Syndrome in a Cervical Cancer Patient -A Case Report", The Korean Journal of Pain, 23(1), pp.88~91 (2010), 대한통증학회
- Fishman LM, "Electrophysiologic evidence of piriformis syndrome", Arch Phys Med Rehabil, 73, pp.359~364 (1992)
- Jankiewicz JJ, "The appearance of the piriformis muscle syndrome in computed tomography and magnetic resonance imaging. A case report and review of the literature", Clin Orthop Relat Res, 262, pp.205~209 (1991)
- Karl RD Jr, "Scintigraphic appearance of the piriformis muscle syndrome", Clin Nucl Med, 10, pp.361~363 (1985)
- Reus M, "Piriformis syndrome: a simple technique for US-guided infiltration of the perisciatic nerve. Preliminary results", Eur Radiol, 18, pp.616~620 (2008)
- Smith J, "Ultrasound- guided piriformis injection: technique description and verification", Arch Phys Med Rehabil, 87, pp.1664~1667 (2006)
- Betts A, "Combined fluoroscopic and nerve stimulator technique for injection of the piriformis muscle", Pain Physician, 7, pp.279~281 (2004)
- Fanucci E, "CT-guided injection of botulinic toxin for percutaneous therapy of piriformis muscle syndrome with preliminary MRI results about denervative process", Eur Radiol, 11, pp.2543~2548 (2001)
- Huerto AP, "Piriformis muscle injection using ultrasonography and motor stimulation--report of a technique", Pain Physician, 10, pp.687~690 (2007)
- Finnoff JT, "Accuracy of ultrasound- guided versus fluoroscopically guided contrast-controlled piriformis injections: a cadaveric study", J Ultrasound Med, 27, pp.1157~1163 (2008)
- Windisch G, "Piriformis muscle: clinical anatomy and consideration of the piriformis syndrome", Surg Radiol Anat, 29, pp.37~45 (2007)
- Russell JM, "Magnetic resonance imaging of the sacral plexus and piriformis muscles", Skeletal Radiol, 37, pp.709~713 (2008)
- Benzon HT, "Piriformis syndrome: anatomic considerations, a new injection technique, and a review of the literature", Anesthesiology, 98, pp.1442~1448 (2003)
