본문 바로가기
KERD
논문KCI 등재

행원 풍력발전단지에서 풍력발전시스템의 운전특성

Operational Characteristics of Wind Turbine Generator Systems in Hangwon Wind Farm

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류기타공학

초록

Abstract

This paper reveals both the operational situation and the cause of the error occurred in wind turbine generator system of Hangwon wind farm in Jeju island. The four wind turbines were selected for this work, and the monitored period was for six months. Wind resource in the wind farm was analyzed, and the estimated energy production was compared with the actual energy production. As a result, with a decrease of system error, the estimated energy production was in good agreement with the actual energy production. The errors occurring in components such as gearbox and hydraulic motor affected the Availability of the wind turbine. Also, poor external conditions such as a strong wind, lightning and gust caused a standstill of wind turbines.

참고문헌 (8)

  1. "대체에너지 개발 용두사미?" (2006)
  2. "행원 풍력발전단지의 WAsP 적용 및 평가", 24(3) (2004), 한국태양에너지학회
  3. "Wind Energy Explained" (2004), John Wiley & Sons Ltd
  4. "풍력공학입문" (2006), 문운당
  5. "Wind Turbine Generator Systems. Part 1: Safety Requirements" (1999)
  6. "Wind Turbine Generator Systems. Part 12: Wind Turbine Power Performance Testing" (1998)
  7. "V42-600kW" (2004)
  8. "BTM Consult ApS, http:", 2006