본문 바로가기
KERD
논문KCI 등재

Endoscopic Electrosurgery in Patients with Cardiac Implantable Electronic Devices

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Patients with cardiac implantable electronic devices (CIEDs) undergoing endoscopic electrosurgery (EE) are at a risk of electromagnetic interference (EMI). We aimed to analyze the effects of EE in CIED patients. Methods: Patients with CIED who underwent EE procedures such as snare polypectomy, endoscopic submucosal dissection (ESD), and endoscopic retrograde cholangiopancreatography (ERCP) with endoscopic sphincterotomy (EST) were retrospectively analyzed. Postprocedural symptoms as well as demographic and outpatient follow-up data were reviewed through medical records. Electrical data, including preprocedural and postprocedural arrhythmia records, were reviewed through pacemaker interrogation, 24-hour Holter monitoring, or electrocardiogram. Results: Fifty-nine procedures in 49 patients were analyzed. Fifty procedures were performed in 43 patients with a pacemaker, and nine were performed in six patients with an implantable cardioverter-defibrillator. There were one gastric and 44 colon snare polypectomies, five gastric and one colon ESDs, and eight ERCPs with EST. Fifty-five cases of electrical follow-up were noted, with two postprocedural changes not caused by EE. Thirty-one pacemaker interrogations had procedure recordings, with two cases of asymptomatic tachycardia. All patients were asymptomatic with no adverse events. Conclusions: Our study reports no adverse events from EE in patients with CIED, suggesting that this procedure is safe. However, because of the possibility of EMI, recommendations on EE should be followed.

Abstract

Background/Aims: Patients with cardiac implantable electronic devices (CIEDs) undergoing endoscopic electrosurgery (EE) are at a risk of electromagnetic interference (EMI). We aimed to analyze the effects of EE in CIED patients. Methods: Patients with CIED who underwent EE procedures such as snare polypectomy, endoscopic submucosal dissection (ESD), and endoscopic retrograde cholangiopancreatography (ERCP) with endoscopic sphincterotomy (EST) were retrospectively analyzed. Postprocedural symptoms as well as demographic and outpatient follow-up data were reviewed through medical records. Electrical data, including preprocedural and postprocedural arrhythmia records, were reviewed through pacemaker interrogation, 24-hour Holter monitoring, or electrocardiogram. Results: Fifty-nine procedures in 49 patients were analyzed. Fifty procedures were performed in 43 patients with a pacemaker, and nine were performed in six patients with an implantable cardioverter-defibrillator. There were one gastric and 44 colon snare polypectomies, five gastric and one colon ESDs, and eight ERCPs with EST. Fifty-five cases of electrical follow-up were noted, with two postprocedural changes not caused by EE. Thirty-one pacemaker interrogations had procedure recordings, with two cases of asymptomatic tachycardia. All patients were asymptomatic with no adverse events. Conclusions: Our study reports no adverse events from EE in patients with CIED, suggesting that this procedure is safe. However, because of the possibility of EMI, recommendations on EE should be followed.

참고문헌 (16)

  1. Boehmer JP, "Device therapy for heart failure", Am J Cardiol, 91(6A), pp.53D~59D (2003)
  2. Vardas PE, "Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association", Eur Heart J, 28, pp.2256~2295 (2007)
  3. Epstein AE, "2012 ACCF", AHA, AHA, pp.HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation, American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society[DOI]
  4. Greenspon AJ, "16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008", J Am Coll Cardiol, 58, pp.1001~1006 (2011)
  5. Mond HG, "The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009. A World Society of Arrhythmia’s project", Pacing Clin Electrophysiol, 34, pp.1013~1027 (2011)
  6. Morris ML, "Electrosurgery in gastrointestinal endoscopy: principles to practice", Am J Gastroenterol, 104, pp.1563~1574 (2009)
  7. Madigan JD, "Surgical management of the patient with an implanted cardiac device:implications of electromagnetic interference", Ann Surg, 230, pp.639~647 (1999)
  8. Parekh PJ, "An update on the management of implanted cardiac devices during electrosurgical procedures", Gastrointest Endosc, 78, pp.836~841 (2013)
  9. Petersen BT, "Endoscopy in patients with implanted electronic devices", Gastrointest Endosc, 65, pp.561~568 (2007)
  10. Crossley GH, "The Heart Rhythm Society (HRS)", American Society of Anesthesiologists (ASA) Expert Consensus Statement on the perioperative management of patients with implantable defibrillators, pacemakers and arrhythmia monitors: facilities and patient management this document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the American Heart Association (AHA), and the Society of Thoracic Surgeons (STS), 2011, pp.8, 1114~1154
  11. Fleisher LA, "2009 ACCF", AHA focused update on perioperative beta blockade incorporated into the ACC, American heart association task force on practice guidelines, pp.Circulation, 2009[DOI]
  12. Cheng A, "Effects of surgical and endoscopic electrocautery on modern-day permanent pacemaker and implantable cardioverter-defibrillator systems", Pacing Clin Electrophysiol, 31, pp.344~350 (2008)
  13. Guertin D, "Electromagnetic interference(EMI)and arrhythmic events in ICD patients undergoing gastrointestinal procedures", Pacing Clin Electrophysiol, 30, pp.734~739 (2007)
  14. Aldrete JA, "The post-anesthesia recovery score revisited", J Clin Anesth, 7, pp.89~91 (1995)
  15. Awad IT, "Factors affecting recovery and discharge following ambulatory surgery", Can J Anaesth, 53, pp.858~872 (2006)
  16. Veitch A, "Endoscopic diathermy in patients with cardiac pacemakers", Endoscopy, 30, pp.544~547 (1998)

관련 논문AI추천

Experiences of magnetic resonance imaging scanning in patients with pacemakers or implantable cardioverter-defibrillators강시혁, 오일영, 조영진, 한동훈대한내과학회 · The Korean Journal of Internal Medicine2019 · 제34권 제1호Feasibility and safety of endoscopic submucosal dissection for lesions in proximity to a colonic diverticulumHirofumi Abe, Hiroya Sakaguchi, Kazunori Tsuda, Kou Miura, Nobuaki Ikezawa, Satoshi Urakami, Shinwa Tanaka, Stuart Kostalas, Takahisa Yamasaki, Takashi Toyonaga, Taku Harada, Tatsuya Nakai, Tetsuya Yoshizaki, Toshitatsu Takao, Yoshinori Morita, Yuzo Kodama대한소화기내시경학회 · Clinical Endoscopy2022 · 제55권 제3호Effect of Antithrombotic Therapy on Bleeding after Argon Plasma Coagulation for Gastric Neoplasms김도훈, 송호준, 안지용, 이진혁, 최기돈, Jung Hwoon-Yong, Jung Kee Wook, Lee Jeong Hoon, Na Hee Kyong, Noh Jin Hee, So Seol거트앤리버 소화기연관학회협의회 · Gut and Liver2022 · 제16권 제2호Clinical Practice and Guidelines for Managing Antithrombotics before and after Endoscopy: A National Survey StudyHoon Jai Chun, Hyungkil Kim, Seong Woo Jeon, Soo Teik Lee, Su Jin Hong거트앤리버 소화기연관학회협의회 · Gut and Liver2020 · 제14권 제3호Endoscopic Retrograde Cholangiopancreatography in Patients with Previous Acute Coronary Syndrome고한라, 김현수, 류종선, 박선영, 박창환, 정명호, 정민우, 최성규, 홍영준거트앤리버 소화기연관학회협의회 · Gut and Liver2014 · 제8권 제6호Determining the Safety and Effectiveness of Electrocautery Enhanced Scissors for Peroral Endoscopic Myotomy (with Video)Christopher C. Thompson, Hiroyuki Aihara, Kelly E. Hathorn, Walter W. Chan대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제4호

이 간행물의 다른 논문 (9건)