Probing inside of concrete structures is one of the important steps in assessing condition of the structure. For the assessment, electromagnetic induction method and electromagnetic wave method are currently applied to the measurement of cover depth, and the detection of reinforcement embedded in concrete. To determine detection capability of locating reinforcement embedded in concrete, commercially available nondestructive testing (NDT) equipments have been tested. The equipments include electromagnetic wave system and electromagnetic induction system. In the tests, nine concrete specimens which have the dimensions of 1,000mm(length)×300mm(width) with thickness varying from 125mm to 150mm are used. The reinforcement are located at 45, 60, 100mm depth from the concrete surface. Horizontal reinforcement spacing has been set over 100mm. From the outcome, it is shown that error is increased as the diameter of reinforcement enlarge in case of using electromagnetic induction method. In case of using electromagnetic wave method, the detection of reinforcement embedded in deep is good in the view of reliability because of using the relative permittivity on the real cover depth.

Abstract

Probing inside of concrete structures is one of the important steps in assessing condition of the structure. For the assessment, electromagnetic induction method and electromagnetic wave method are currently applied to the measurement of cover depth, and the detection of reinforcement embedded in concrete. To determine detection capability of locating reinforcement embedded in concrete, commercially available nondestructive testing (NDT) equipments have been tested. The equipments include electromagnetic wave system and electromagnetic induction system. In the tests, nine concrete specimens which have the dimensions of 1,000mm(length)×300mm(width) with thickness varying from 125mm to 150mm are used. The reinforcement are located at 45, 60, 100mm depth from the concrete surface. Horizontal reinforcement spacing has been set over 100mm. From the outcome, it is shown that error is increased as the diameter of reinforcement enlarge in case of using electromagnetic induction method. In case of using electromagnetic wave method, the detection of reinforcement embedded in deep is good in the view of reliability because of using the relative permittivity on the real cover depth.

참고문헌 (17)

  1. 임창덕, "전자파, 방사선, 적외선 등을 이용한 비파괴 시험", 한국콘크리트학회, ~, pp.콘크리트구조물의 비파괴검 사 및 안전진단 제2회 기술강좌 (1993)
  2. 건교부, "시설물 안전진단 장비의 사용 및 유지관리 매뉴얼", 건교부, 시설안전기술공단, 11~92 (2000)
  3. 김영환, "콘크리트 구조물의 비파괴검사 현황", 비파괴 검사학회지, 20(4) (2000)
  4. "전자기유도법에 의한 철근탐사 시험방법", ~, pp.KS F 2734 (2004)
  5. 박승범, "콘크리트진단 및 유지관리" (2002), 기문당
  6. 박승범, "콘크리트 구조물의 진단 및 유지관리 콘크리트의 제조시공품질관리 및 유지관리 제3회 기술강좌", 한국 콘크리트학회 (2004)
  7. 박기준, "구조물 진단장비를 이용한 철근탐사", 대한건축학회 학술발표논문집, 20(1), pp.189~192 (2000)
  8. 박석균, "전자파를 이용한 콘크리트 구조물의 비파괴검사", 콘크리트학회지, 10(2), pp.27~39 (1998)
  9. 임홍철, "레이다를 이용한 콘크리트 시편내 수평 배근간격 탐사", 한국지진공학회 논문집, 4(2), pp.65~71 (2000)
  10. 임홍철, "레이더를 이용한 콘크리트 구조물의 비파괴 검사 방법 개발", ’99 학술 제2분과 워크샵 (1999)
  11. "전자파레이더법에 의한 철근탐사 시험 방법", ~, pp.KS F 2735 (2004)
  12. 건교부, "교량정밀안전진단 및 통 과허용하중 산정기법 개선(2차)", ~ (1999)
  13. 한국시설안전기술공단, "시설물의 건전성평가를 위한 비파괴 및 재하시험매뉴얼 개발", 한국시설안전기술공단, ~ (2006)
  14. 임홍철, "비파괴 방법에 의한 지진후 피해평가", 콘크리트학회지, 9(2) (1997)
  15. コンクリト 構造物の健全度診斷技術の開發に 關す 共同硏究報告書, "建設省土木硏究所 コンクリト 硏究室", ~, pp.第106号 (1994)
  16. Rhim, H. C., "Detection of Steel Reinforcing Bars inside Concrete Using Radar", pp.577~581 (2000), Non-Destructive Testing in Civil Engineering, Edited by Taketo Uomoto
  17. Cheng, D.K., "Field and Wave Electromagnetics", pp.703~ (1989), Addison-Wesley Pub. Co.