Concurrent Validity and Reliability of Ultrasound-based Muscle Thickness and Inclinometer-based Range of Motion Measurements in Assessing Stretching-induced Changes in Muscle Flexibility in Healthy Adults

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류물리치료학

초록

Background: Muscle thickness (MT) measurement using ultrasound image is emerging as a useful method to assess muscle mass during stretching. Traditionally, range of motion (ROM) measurements assessed by digital inclinometer are considered reliable and valid parameter for monitoring muscle flexibility. The ultrasound-based measurement for MT to monitor muscle flexibility has yet to be validated. Objects: This study aimed to determine whether ultrasound measurement can serve as a valid alternative to a digital inclinometer for assessing muscle flexibility following stretching interventions. Methods: A randomized crossover design study was conducted with 20 healthy young participants. The stretching exercise program was carried out passive static and hold-relax proprioceptive neuromuscular facilitation stretching exercises applied on gastrocnemius-soleus muscle group with 3 times a week for 2 weeks. Data were collected 3 times for pre- and post-tests. Dorsiflexion ROM was measured by a digital inclinometer and the MT of gastrocnemius muscle by the ultrasound. Intraclass correlation coefficient (ICC) analysis for test-retest reliability, Wilcoxon sign rank test for stretching effects, and Spearman’s correlation analysis for determining the concurrent validity of two measurements. Results: ICC values of pre- and post-tests in both ROM and MT measurements were showed good to excellent intra rater reliabilities ranging from 0.782 to 0.968 (p < 0.001). A significant increase in the ROM measurements was observed following the stretching program (p < 0.01), whereas no significant change in the MT measurement was showed. Spearman’s correlations revealed weak relationships between the ROM and MT measurements (r = –0.217 for pre-test, r = –0.259 for post-test, r = –0.282, p < 0.05 for changes). Conclusion: These findings suggest that both the MT and ROM measurements were not compatible for monitoring muscle flexibility following stretching exercises regardless of their good reliabilities. Further investigations may be required to the MT measurement alone to be an alternative method.

Abstract

Background: Muscle thickness (MT) measurement using ultrasound image is emerging as a useful method to assess muscle mass during stretching. Traditionally, range of motion (ROM) measurements assessed by digital inclinometer are considered reliable and valid parameter for monitoring muscle flexibility. The ultrasound-based measurement for MT to monitor muscle flexibility has yet to be validated. Objects: This study aimed to determine whether ultrasound measurement can serve as a valid alternative to a digital inclinometer for assessing muscle flexibility following stretching interventions. Methods: A randomized crossover design study was conducted with 20 healthy young participants. The stretching exercise program was carried out passive static and hold-relax proprioceptive neuromuscular facilitation stretching exercises applied on gastrocnemius-soleus muscle group with 3 times a week for 2 weeks. Data were collected 3 times for pre- and post-tests. Dorsiflexion ROM was measured by a digital inclinometer and the MT of gastrocnemius muscle by the ultrasound. Intraclass correlation coefficient (ICC) analysis for test-retest reliability, Wilcoxon sign rank test for stretching effects, and Spearman’s correlation analysis for determining the concurrent validity of two measurements. Results: ICC values of pre- and post-tests in both ROM and MT measurements were showed good to excellent intra rater reliabilities ranging from 0.782 to 0.968 (p < 0.001). A significant increase in the ROM measurements was observed following the stretching program (p < 0.01), whereas no significant change in the MT measurement was showed. Spearman’s correlations revealed weak relationships between the ROM and MT measurements (r = –0.217 for pre-test, r = –0.259 for post-test, r = –0.282, p < 0.05 for changes). Conclusion: These findings suggest that both the MT and ROM measurements were not compatible for monitoring muscle flexibility following stretching exercises regardless of their good reliabilities. Further investigations may be required to the MT measurement alone to be an alternative method.

관련 논문AI추천

Comparison of the Duration of Maintained Calf Muscle Flexibility After Static Stretching, Eccentric Training on Stable Surface, and Eccentric Training on Unstable Surfaces in Young Adults With Calf Muscle Tightness김선엽, 장현정, 장희진한국전문물리치료학회 · 한국전문물리치료학회지2014 · 제21권 제2호Comparison of Two Static Stretching Techniques for the Triceps Surae in Healthy Individuals: Wall and Inclined Board StretchingsJu Kang Lee, Ki Deok Park, Oh Kyung Lim, Tae Hee Kim대한재활의학회 · Annals of Rehabilitation Medicine2020 · 제44권 제2호A Comparative Study of Optimal Stretch Intensity For Flexibility of Hamstrings; Hand Held Dynamometer and Verbal Rating Scalechoi bongsam한국전문물리치료학회 · 한국전문물리치료학회지2017 · 제24권 제4호에비안스-함베르크 스트레칭 방법이 고관절의 능동 가동범위와 우모각에 미치는 영향장기연, 천승철한국전문물리치료학회 · 한국전문물리치료학회지2010 · 제17권 제2호다양한 강도에서 수행된 고유감각신경근육촉진 스트레칭과 정적 스트레칭이 뒤넙다리근의 유연성에 미치는 효과임우택한국전문물리치료학회 · 한국전문물리치료학회지2020 · 제27권 제1호Immediate Effects of High-frequency Diathermy on Muscle Architecture and Flexibility in Subjects With Gastrocnemius Tightness박주희, 전혜선, Hyeo-bin Yoon, Ji-hyun Kim, Jun-hyeok Lee한국전문물리치료학회 · 한국전문물리치료학회지2020 · 제27권 제2호

이 간행물의 다른 논문 (9건)