Background and Objectives The purpose of this study was to share our clinical experience on the use of bioresorbable poly L-/DL-lactide 70/30 implant to repair blow out fracture. Subjects and Method The medical records of 130 patients with orbital fractures that were treated surgically from June 2006 to February 2011 were reviewed retrospectively. Patients who had diplopia or limited extraocular motion, significant Enophthalmos (>2 mm), or a large orbital wall fracture on a computed tomographic scan were enrolled for the study. We investigated diplopia, limited extraoacular motion, enophthalmos before and after surgery. Results The mean postoperative follow-up was 28 months. There was no evidence of sinus infection related to the implant. However, six patients showed dislocation of orbital implant in the nasal cavity. After six postoperative months, diplopia was seen in 1 (2%) patient, and significant enophthalmos was seen 2 (2%) patients. We carried out re-operation on six cases and the main cause was incomplete reduction or over reduction. Conclusion Bioresorbable poly L-/DL-lactide 70/30 implants are safe and reliable for the reduction for blowout fracture. Korean J Otorhinolaryngol-Head Neck Surg 2014;57(11):759-65

Abstract

Background and Objectives The purpose of this study was to share our clinical experience on the use of bioresorbable poly L-/DL-lactide 70/30 implant to repair blow out fracture. Subjects and Method The medical records of 130 patients with orbital fractures that were treated surgically from June 2006 to February 2011 were reviewed retrospectively. Patients who had diplopia or limited extraocular motion, significant Enophthalmos (>2 mm), or a large orbital wall fracture on a computed tomographic scan were enrolled for the study. We investigated diplopia, limited extraoacular motion, enophthalmos before and after surgery. Results The mean postoperative follow-up was 28 months. There was no evidence of sinus infection related to the implant. However, six patients showed dislocation of orbital implant in the nasal cavity. After six postoperative months, diplopia was seen in 1 (2%) patient, and significant enophthalmos was seen 2 (2%) patients. We carried out re-operation on six cases and the main cause was incomplete reduction or over reduction. Conclusion Bioresorbable poly L-/DL-lactide 70/30 implants are safe and reliable for the reduction for blowout fracture. Korean J Otorhinolaryngol-Head Neck Surg 2014;57(11):759-65

참고문헌 (25)

  1. LA 70, "30) plates are reliable for repairing large inferior orbital wall bony defects: a pilot study", J Oral Maxillofac Surg, 64(1), pp.47~55 (2006)
  2. Hinohira Y, "Endoscopic endonasal management of medial orbital blowout fractures", Facial Plast Surg, 25(1), pp.17~22 (2009)
  3. 박성원, "Π형 1mm 두께 실라스틱 시트와 압축 Merocel? 충전을 이용한 안와내벽 외향골절의 비내시경적 비내정복술 치험 1예", 대한이비인후과학회지 두경부외과학, 47(1), pp.75~78 (2004), 대한이비인후과학회
  4. We J, "Modified technique for endoscopic endonasal reduction of medial orbital wall fracture using a resorbable panel", Ophthal Plast Reconstr Surg, 25(4), pp.303~305 (2009)
  5. 권재환, "안와 외향 골절의 최신 치료", 대한이비인후과학회지 두경부외과학, 54(5), pp.317~323 (2011), 대한이비인후과학회
  6. Appling WD, "Transconjunctival approach vs subciliary skin-muscle flap approach for orbital fracture repair", Arch Otolaryngol Head Neck Surg, 119(9), pp.1000~1007 (1993)
  7. Persons BL, "Transantral endoscopic orbital floor repair using resorbable plate", J Craniofac Surg, 13(3), pp.483~488 (2002)
  8. Holmes RE, "MacroPore resorbable devices in craniofacial surgery", Clin Plast Surg, 31(3), pp.393~406 (2004)
  9. Kontio RK, "Reconstruction of internal orbital wall fracture with iliac crest free bone graft: clinical, computed tomography, and magnetic resonance imaging follow-up study", Plast Reconstr Surg, 118(6), pp.1365~1374 (2006)
  10. Krishnan V, "Orbital floor reconstruction with autogenous mandibular symphyseal bone grafts", J Oral Maxillofac Surg, 55(4), pp.327~330 (1997)
  11. Kraus M, "Repair of traumatic inferior orbital wall defects with nasoseptal cartilage", J Oral Maxillofac Surg, 59(12), pp.1397~1400 (2001)
  12. Custer PL, "Complications of supramid orbital implants", Ophthal Plast Reconstr Surg, 19(1), pp.62~67 (2003)
  13. Morrison AD, "The use of silastic as an orbital implant for reconstruction of orbital wall defects: review of 311 cases treated over 20 years", J Oral Maxillofac Surg, 53(4), pp.412~417 (1995)
  14. Villarreal PM, "Porous polyethylene implants in orbital floor reconstruction", Plast Reconstr Surg, 109(3), pp.877~885 (2002)
  15. Yilmaz M, "Repair of fractures of the orbital floor with porous polyethylene implants", Br J Oral Maxillofac Surg, 45(8), pp.640~644 (2007)
  16. Musadiq M, "Abscessed porous polyethylene (Medpor) orbital implant: a case report", Orbit, 27(2), pp.127~129 (2008)
  17. Mauriello JA Jr, "Use of Vicryl (polyglactin-910)mesh implant for repair of orbital floor fracture causing diplopia: a study of 28 patients over 5 years", Ophthal Plast Reconstr Surg, 9(3), pp.191~195 (1993)
  18. Iizuka T, "Reconstruction of orbital floor with polydioxanone plate", Int J Oral Maxillofac Surg, 20(2), pp.83~87 (1991)
  19. Peltoniemi HH, "Consolidation of craniotomy lines after resorbable polylactide and titanium plating: a comparative experimental study in sheep", Plast Reconstr Surg, 101(1), pp.123~133 (1998)
  20. plate, "J Oral Maxillofac Surg", 2006, 1098~1048
  21. Lieger O, "Repair of orbital floor fractures using bioresorbable poly-L", DL-lactide plates, 2010, pp.12(6), 399~404
  22. 김인재, "안와파열골절 정복술 후 지속되는 복시와 안구함몰에 대한 분석", 대한안과학회지, 44(10), pp.3~2212 (2003), 대한안과학회
  23. Hsieh CH, "Indirect traumatic optic neuropathy complicated with periorbital facial bone fracture", J Trauma, 56(4), pp.795~801 (2004)
  24. 권민상, "안와 외향골절 정복술에서 치료성적 및 술후 합병증 분석", 대한이비인후과학회지 두경부외과학, 49(8), pp.802~806 (2006), 대한이비인후과학회
  25. 문정환, "실리콘 튜브의 탄성을 이용한 안와하벽골절 정복술", 대한이비인후과학회지 두경부외과학, 46(12), pp.1046~1050 (2003), 대한이비인후과학회