본문 바로가기
KERD
논문KCI 등재

Comparison of clinical utility between diaphragm excursion and thickening change using ultrasonography to predict extubation success

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Both diaphragmatic excursion and change in muscle thickening are measured using ultrasonography (US) to assess diaphragm function and mechanical ventilation weaning outcomes. However, which parameter can better predict successful extubation remains to be determined. The aim of this study was to compare the clinical utility of these two diaphragmatic parameters to predict extubation success. Methods: This study included patients subjected to extubation trial in the medical or surgical intensive care unit of a university-affiliated hospital from May 2015 through February 2016. Diaphragm excursion and percent of thickening change (Δtdi%) were measured using US within 24 hours before extubation. Results: Sixty patients were included, and 78.3% (47/60) of these patients were successfully extubated, whereas 21.7% (13/60) were not. The median degree of excursion was greater in patients with extubation success than in those with extubation failure (1.65 cm vs. 0.8 cm, p < 0.001). Patients with extubation success had a greater Δtdi% than those with extubation failure (42.1% vs. 22.5%, p = 0.03). The areas under the receiver operating curve for excursion and Δtdi% were 0.836 (95% confidence interval [CI], 0.717 to 0.919) and 0.698 (95% CI, 0.566 to 0.810), respectively (p = 0.017). Conclusions: Diaphragm excursion seems more accurate than a change in the diaphragm thickness to predict extubation success.

Abstract

Background/Aims: Both diaphragmatic excursion and change in muscle thickening are measured using ultrasonography (US) to assess diaphragm function and mechanical ventilation weaning outcomes. However, which parameter can better predict successful extubation remains to be determined. The aim of this study was to compare the clinical utility of these two diaphragmatic parameters to predict extubation success. Methods: This study included patients subjected to extubation trial in the medical or surgical intensive care unit of a university-affiliated hospital from May 2015 through February 2016. Diaphragm excursion and percent of thickening change (Δtdi%) were measured using US within 24 hours before extubation. Results: Sixty patients were included, and 78.3% (47/60) of these patients were successfully extubated, whereas 21.7% (13/60) were not. The median degree of excursion was greater in patients with extubation success than in those with extubation failure (1.65 cm vs. 0.8 cm, p < 0.001). Patients with extubation success had a greater Δtdi% than those with extubation failure (42.1% vs. 22.5%, p = 0.03). The areas under the receiver operating curve for excursion and Δtdi% were 0.836 (95% confidence interval [CI], 0.717 to 0.919) and 0.698 (95% CI, 0.566 to 0.810), respectively (p = 0.017). Conclusions: Diaphragm excursion seems more accurate than a change in the diaphragm thickness to predict extubation success.

참고문헌 (23)

  1. Epstein SK, "Effect of failed extubation on the outcome of mechanical ventilation", Chest, 112, pp.186~192 (1997)[DOI]
  2. Epstein SK, "Decision to extubate", Intensive Care Med, 28, pp.535~546 (2002)[DOI]
  3. McCool FD, "Dysfunction of the diaphragm", N Engl J Med, 366, pp.932~942 (2012)[DOI]
  4. Heunks LM, "Monitoring and preventing diaphragm injury", Curr Opin Crit Care, 21, pp.34~41 (2015)[DOI]
  5. Matamis D, "Sonographic evaluation of the diaphragm in critically ill patients: technique and clinical applications", Intensive Care Med, 39, pp.801~810 (2013)[DOI]
  6. Kim WY, "Diaphragm dysfunction assessed by ultrasonography: influence on weaning from mechanical ventilation", Crit Care Med, 39, pp.2627~2630 (2011)[DOI]
  7. DiNino E, "Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation", Thorax, 69, pp.423~427 (2014)
  8. Cohn D, "Diaphragm thickening during inspiration", J Appl Physiol (1985), 83, pp.291~296 (1997)[DOI]
  9. Boles JM, "Weaning from mechanical ventilation", Eur Respir J, 29, pp.1033~1056 (2007)[DOI]
  10. Artime CA, "Tracheal extubation", Respir Care, 59, pp.991~1002 (2014)[DOI]
  11. Thille AW, "Outcomes of extubation failure in medical intensive care unit patients", Crit Care Med, 39, pp.2612~2618 (2011)[DOI]
  12. Frutos-Vivar F, "Outcome of reintubated patients after scheduled extubation", J Crit Care, 26, pp.502~509 (2011)[DOI]
  13. Yang KL, "A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation", N Engl J Med, 324, pp.1445~1450 (1991)[DOI]
  14. Lee KH, "Rapid shallow breathing (frequency-tidal volume ratio) did not predict extubation outcome", Chest, 105, pp.540~543 (1994)[DOI]
  15. Demoule A, "Diaphragm dysfunction on admission to the intensive care unit: prevalence, risk factors, and prognostic impact: a prospective study", Am J Respir Crit Care Med, 188, pp.213~219 (2013)[DOI]
  16. Doorduin J, "Monitoring of the respiratory muscles in the critically ill", Am J Respir Crit Care Med, 187, pp.20~27 (2013)[DOI]
  17. Sarwal A, "Neuromuscular ultrasound for evaluation of the diaphragm", Muscle Nerve, 47, pp.319~329 (2013)[DOI]
  18. Boon AJ, "Sensitivity and specificity of diagnostic ultrasound in the diagnosis of phrenic neuropathy", Neurology, 83, pp.1264~1270 (2014)[DOI]
  19. Boussuges A, "Diaphragmatic motion studied by m-mode ultrasonography: methods, reproducibility, and normal values", Chest, 135, pp.391~400 (2009)[DOI]
  20. Valette X, "Diaphragmatic dysfunction at admission in intensive care unit: the value of diaphragmatic ultrasonography", Intensive Care Med, 41, pp.557~559 (2015)[DOI]
  21. Mariani LF, "Ultrasonography for screening and follow-up of diaphragmatic dysfunction in the ICU: a pilot study", J Intensive Care Med, 31, pp.338~343 (2016)[DOI]
  22. Goligher EC, "Measuring diaphragm thickness with ultrasound in mechanically ventilated patients: feasibility, reproducibility and validity", Intensive Care Med, 41, pp.642~649 (2015)[DOI]
  23. Ferrari G, "Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation", Crit Ultrasound J, 6, pp.8~ (2014)[DOI]

관련 논문AI추천

Diaphragm ultrasound as a better predictor of successful extubation from mechanical ventilation than rapid shallow breathing indexFahmida Khatun Padma, Harun-Or Rashid, Khairul Islam Nipun, Mohammad Azmain Iktidar, Mohammad Jhahidul Alam, Ranjan Kumar Nath, Simanta Roy, Sreshtha Chowdhury대한중환자의학회 · Acute and Critical Care2022 · 제37권 제1호The role of diaphragmatic thickness measurement in weaning prediction and its comparison with rapid shallow breathing index: a single-center experienceDhruva Chaudhry, Lokesh Kumar Lalwani, Manjunath B Govindagoudar, Mukesh Sharma, Pawan Kumar Singh대한중환자의학회 · Acute and Critical Care2022 · 제37권 제3호Comparison of clinical utility between diaphragm excursion and thickening change using ultrasonography to predict extubation success김호철, 유정완, 이승준, 이종덕대한내과학회 · The Korean Journal of Internal Medicine2019 · 제34권 제3호Diaphragm ultrasound in weaning from mechanical ventilation: a last step to predict successful extubation?Costanzo Domenica Di, Esquinas Antonio, Mazza Mariano대한중환자의학회 · Acute and Critical Care2022 · 제37권 제4호Diaphragm ultrasound for predicting weaning success in post-cardiac surgery acute respiratory distress syndrome patients: a prospective observational study in ChinaDou-Dou Xiang, Pei Yu, Quan Gan, Yuan-Qin Huang대한중환자의학회 · Acute and Critical Care2025 · 제40권 제3호Thoracic fluid content by electrical cardiometry versus diaphragmatic excursion by ultrasound for the prediction of weaning success in patients with lung congestionAhmed Mostafa Abdelhamid, Enas Wageh Mahdy, Samar Rafik Amin, Shawky Meselhy Elshaer대한중환자의학회 · Acute and Critical Care2025 · 제40권 제4호