What is the Adequate Cuff Volume for Tracheostomy Tube? A Pilot Cadaver Study
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective To determine the patterns of tracheostomy cuff pressure changes with various air inflation amounts in different types of tracheostomy tubes to obtain basic data for appropriately managing long-term tracheostomy. Methods We performed tracheostomy on a 46-year-old male cadaver. Three types of tracheostomy tubes (single-cuffed, double-cuffed, and adjustable flange), divided into 8 different subtypes based on internal tube diameters and cuff diameters, were inserted into the cadaver. Air was inflated into the cuff, and starting with 1 mL air, the cuff pressure was subsequently measured using a manometer. Results For the 7.5 mm/14 mm tracheostomy tube, cuff inflation with 3 mL of air yielded a cuff pressure within the recommended range of 20–30 cmH2O. The 7.5 mm/24 mm tracheostomy tube showed adequate cuff pressure at 5 mL of air inflation. Similar values were observed for the 8.0 mm/16 mm and 8.0 mm/27 mm tubes. Double-cuffed tracheostomy cuff pressures (7.5 mm/20 mm and 8.0 mm/20 mm tubes) at 3 mL air inflation had cuff pressures of 18–20 cmH2O at both the proximal and distal sites. For the adjustable flange tracheostomy tube, cuff pressure at 6 mL of cuff air inflation was within the recommended range. Maximal cuff pressure was achieved at inflation with almost 14 mL of air, unlike other tube types. Conclusion Various types of tracheostomy tubes showed different cuff pressures after inflation. These values might aid in developing guidelines For patients who undergo tracheostomy and are discharged home without cuff pressure manometers, this standard might be helpful to develop guidelines.
Abstract
Objective To determine the patterns of tracheostomy cuff pressure changes with various air inflation amounts in different types of tracheostomy tubes to obtain basic data for appropriately managing long-term tracheostomy. Methods We performed tracheostomy on a 46-year-old male cadaver. Three types of tracheostomy tubes (single-cuffed, double-cuffed, and adjustable flange), divided into 8 different subtypes based on internal tube diameters and cuff diameters, were inserted into the cadaver. Air was inflated into the cuff, and starting with 1 mL air, the cuff pressure was subsequently measured using a manometer. Results For the 7.5 mm/14 mm tracheostomy tube, cuff inflation with 3 mL of air yielded a cuff pressure within the recommended range of 20–30 cmH2O. The 7.5 mm/24 mm tracheostomy tube showed adequate cuff pressure at 5 mL of air inflation. Similar values were observed for the 8.0 mm/16 mm and 8.0 mm/27 mm tubes. Double-cuffed tracheostomy cuff pressures (7.5 mm/20 mm and 8.0 mm/20 mm tubes) at 3 mL air inflation had cuff pressures of 18–20 cmH2O at both the proximal and distal sites. For the adjustable flange tracheostomy tube, cuff pressure at 6 mL of cuff air inflation was within the recommended range. Maximal cuff pressure was achieved at inflation with almost 14 mL of air, unlike other tube types. Conclusion Various types of tracheostomy tubes showed different cuff pressures after inflation. These values might aid in developing guidelines For patients who undergo tracheostomy and are discharged home without cuff pressure manometers, this standard might be helpful to develop guidelines.
참고문헌 (22)
- Sengupta P, "Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure", BMC Anesthesiol, 4, pp.8~ (2004)
- Braz JR, "Endotracheal tube cuff pressure : need for precise measurement", Sao Paulo Med J, 117, pp.243~247 (1999)
- Stauffer JL, "Complications and consequences of endotracheal intubation and tracheotomy : a prospective study of 150 critically ill adult patients", Am J Med, 70, pp.65~76 (1981)
- Leigh JM, "Pressure on the tracheal mucosa from cuffed tubes", Br Med J, 1, pp.1173~1174 (1979)
- Nordin U, "The trachea and cuff-induced tracheal injury : an experimental study on causative factors and prevention", Acta Otolaryngol Suppl, 345, pp.1~71 (1977)
- Klainer AS, "Surface alterations due to endotracheal intubation", Am J Med, 58, pp.674~683 (1975)
- Shelly WM, "Cuffed tubes as a cause of tracheal stenosis", J Thorac Cardiovasc Surg, 57, pp.623~627 (1969)
- Bernhard WN, "Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics", Chest, 87, pp.720~725 (1985)
- Bernhard WN, "Adjustment of intracuff pressure to prevent aspiration", Anesthesiology, 50, pp.363~366 (1979)
- Bryant LR, "Reappraisal of tracheal injury from cuffed tracheostomy tubes : experiments in dogs", JAMA, 215, pp.625~628 (1971)
- 박여진, "Care Status of the ALS Patients With Long-Term Use of Tracheostomy Tube", Annals of Rehabilitation Medicine, 39(6), pp.964~970 (2015), 대한재활의학회
- 서미리, "Long-Term Outcome of Amyotrophic Lateral Sclerosis in Korean Subjects", Annals of Rehabilitation Medicine, 41(6), pp.1055~1064 (2017), 대한재활의학회
- Fernandez R, "Endotracheal tube cuff pressure assessment : pitfalls of finger estimation and need for objective measurement", Crit Care Med, 18, pp.1423~1426 (1990)
- Dunn CR, "Determinants of tracheal injury by cuffed tracheostomy tubes", Chest, 65, pp.128~135 (1974)
- Lewis FR Jr, "Prevention of complications from prolonged tracheal intubation", Am J Surg, 135, pp.452~457 (1978)
- Durbin CG Jr, "Techniques for performing tracheostomy", Respir Care, 50, pp.488~496 (2005)
- Hess DR, "Tracheostomy tubes and related appliances", Respir Care, 50, pp.497~510 (2005)
- Breatnach E, "Dimensions of the normal human trachea", AJR Am J Roentgenol, 142, pp.903~906 (1984)
- St John RE, "Contemporary issues in adult tracheostomy management", Crit Care Nurs Clin North Am, 16, pp.413~430 (2004)
- Otoch JP, "Is there a correlation between right bronchus length and diameter with age?", J Thorac Dis, 5, pp.306~309 (2013)
- Al-Shaikh B, "Essentials of equipment in anaesthesia, critical care, and peri-operative medicine" (2018), Elsevier
- Dullenkopf A, "Fluid leakage past tracheal tube cuffs : evaluation of the new Microcuff endotracheal tube", Intensive Care Med, 29, pp.1849~1853 (2003)
