견봉하 삼각근하 점액낭 주사 시 맹검 접근법과 초음파 하 접근법의 비교
Comparision of Blind Technique and Ultrasonography Guided Technique of Subacromial Subdeltoid Bursa Injection
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Objective: To evaluate the accuracy and effect of ultrasonography guided subacromial subdeltoid (SASD) bursa injection on the shoulder pain and function compared to blind technique. Method: Twenty-eight patients diagnosed as SASD bursitis were administered with SASD injection of corticosteroids randomly by either blind or US guided technique and then assessed by ultrasonography to confirm the accuracy. Shoulder pain and function were evaluated by visual analog scale with Hawkin’s impingement test, active range of motion (ROM) of the shoulder, University of California-Los Angeles (UCLA) shoulder rating scale before and 1 week after the injection. Results: The accuracy of SASD injection using blind technique was 42.8%, however, US-guided injection showed 100% accuracy, significantly higher than blind technique (p<0.05). We could find significant improvement in pain with Hawkin’s impingement test, active ROM of the shoulder, UCLA shoulder rating scale 1 week after injection in both groups. But there were no significant differences between the groups. In eight patients, failure was observed: four in the suprascapularis tendon, three in the deltoid muscle, and one in the subcutaneous tissue without side effects. Conclusion: Ultasonography guided injection into SASD bursa improved the accuracy of injection. However the injection method and the success of injection did not affect to the pain and shoulder function. (J Korean Acad Rehab Med 2010; 34: 209-213)
Abstract
Objective: To evaluate the accuracy and effect of ultrasonography guided subacromial subdeltoid (SASD) bursa injection on the shoulder pain and function compared to blind technique. Method: Twenty-eight patients diagnosed as SASD bursitis were administered with SASD injection of corticosteroids randomly by either blind or US guided technique and then assessed by ultrasonography to confirm the accuracy. Shoulder pain and function were evaluated by visual analog scale with Hawkin’s impingement test, active range of motion (ROM) of the shoulder, University of California-Los Angeles (UCLA) shoulder rating scale before and 1 week after the injection. Results: The accuracy of SASD injection using blind technique was 42.8%, however, US-guided injection showed 100% accuracy, significantly higher than blind technique (p<0.05). We could find significant improvement in pain with Hawkin’s impingement test, active ROM of the shoulder, UCLA shoulder rating scale 1 week after injection in both groups. But there were no significant differences between the groups. In eight patients, failure was observed: four in the suprascapularis tendon, three in the deltoid muscle, and one in the subcutaneous tissue without side effects. Conclusion: Ultasonography guided injection into SASD bursa improved the accuracy of injection. However the injection method and the success of injection did not affect to the pain and shoulder function. (J Korean Acad Rehab Med 2010; 34: 209-213)
참고문헌 (19)
- Bigliani LU, "Subacromial impingement syndrome", J Bone Joint Surg Am, 79, pp.1854~1868 (1997)
- Gruson KI, "Subacromial corticosteroid injection", J Shoulder Elbow Surg, 17, pp.118~130 (2008)
- Brox JI, "Regional musculoskeletal conditions: shoulder pain", Best Pract Res Clin Rheumatol, 17, pp.33~56 (2003)
- Petri M, "Randomized, double-blind, placebo-controlled study of the treatment of the painful shoulder", Arthritis Rheum, 30, pp.1040~1045 (1987)
- Blair B, "Efficacy of injections of corticosteroids for subacromial impingement syndrome", J Bone Joint Surg (Am), 78, pp.1685~1689 (1996)
- Rutten MJ, "Injection of subacromial-subdeltoid bursa: blind or ultrasound-guided?", Acta Orthopaedica, 78, pp.254~257 (2007)
- Eustace JA, "Comparison of the accuracy of steroid placement with clinical outcome in patients with shoulder symptoms", Ann Rheum Dis, 56, pp.59~63 (1997)
- Esenyel CZ, "The correlation between the accuracy of steroid injections and subsequent shoulder pain and function in subaromial impingement syndrome", Acta Orthop Traumatol Turc, 37, pp.41~45 (2003)
- Naredo E, "A randomized comparative study of short term response to blind injection versus sonographic- guided injection of local corticosteroids in patients with painful shoulder", J Rheumatol, 31, pp.308~314 (2004)
- Kang MN, "The accuracy of subacromial corticosteroid injection: a comparision of multiple method", J Shoulder Elbow Surg, 17, pp.61~66 (2008)
- Rizk TE, "Frozen shoulder", Semin Arthritis Rheum, 11, pp.440~452 (1982)
- Bianchi S, "Ultrasound of the Musculoskeletal System", pp.303~304 (2007), Springer
- Ferri M, "Sonography of full-thickness supraspinatus tears: comparision of patient positioning technique with surgical correlation", Am J Roentgenol, 184, pp.180~184 (2005)
- McNally EG, "Practical musculoskeletal ultrasound", pp.285~ (2005), Elsevier science
- Zordo TD, "US guided injections in arthritis", Eur J Radiol, 71, pp.197~203 (2009)
- Partington PF, "Diagnostic injection around the shoulder: hit and miss? A cadaveric study of injection accuracy", J Shoulder Elbow Surg, 7, pp.147~150 (1998)
- 이태임, "견관절 내 주사 시 맹검 접근법과 초음파하 접근법의 비교", Annals of Rehabilitation Medicine, 30(1), pp.45~50 (2006), 대한재활의학회
- Yamakado K, "The targeting accuracy of subacromial injection to the shoulder: an arthrographic evaluation", Arthroscopy, 18, pp.887~891 (2002)
- Birkinshaw R, "Necrotising faciitis as a complication of steroid injection", J Accid Emerg Med, 14, pp.52~54 (1997)