본문 바로가기
KERD
논문KCI 등재

Impact of an expanded reimbursement policy on utilization of implantable loop recorders in patients with cryptogenic stroke in Korea

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: The reimbursement policy for cryptogenic stroke (CS) was expanded in November 2018 from recurrent strokes to the first stroke episode. No reports have demonstrated whether this policy change has affected trends in implantable loop recorder (ILR) utilization. Methods: We identified patients who received an ILR implant using the Korea Health Insurance Review and Assessment Service database between July 2016 and October 2021. Patients meeting all the following criteria were considered to have CS indication: 1) prior stroke history, 2) no previous history of atrial fibrillation or flutter (AF/AFL), and 3) no maintenance of oral anticoagulant for ≥4 weeks within a year before ILR implant. AF/AFL diagnosed within 3 years after ILR implant or before ILR removal was considered ILR-driven. Results: Among 3,056 patients, 1,001 (32.8%) had CS indications. The total ILR implant number gradually increased for both CS and non-CS indications and the number of CS indication significantly increased after implementing the expanded reimbursement policy. The detection rate for AF/AFL was 26.3% in CS patients over 3 years, which was significantly higher in patients implanted with an ILR within 2 months after stroke than those implanted later. Conclusions: The expanded coverage policy for CS had a significant impact on the number of ILR implantation for CS indication. The diagnostic yield of ILR for AF/AFL detection seems better when ILR is implanted within 2 months than later. Further investigation is needed to demonstrate other clinical benefits and the optimal ILR implantation timing.

Abstract

Background/Aims: The reimbursement policy for cryptogenic stroke (CS) was expanded in November 2018 from recurrent strokes to the first stroke episode. No reports have demonstrated whether this policy change has affected trends in implantable loop recorder (ILR) utilization. Methods: We identified patients who received an ILR implant using the Korea Health Insurance Review and Assessment Service database between July 2016 and October 2021. Patients meeting all the following criteria were considered to have CS indication: 1) prior stroke history, 2) no previous history of atrial fibrillation or flutter (AF/AFL), and 3) no maintenance of oral anticoagulant for ≥4 weeks within a year before ILR implant. AF/AFL diagnosed within 3 years after ILR implant or before ILR removal was considered ILR-driven. Results: Among 3,056 patients, 1,001 (32.8%) had CS indications. The total ILR implant number gradually increased for both CS and non-CS indications and the number of CS indication significantly increased after implementing the expanded reimbursement policy. The detection rate for AF/AFL was 26.3% in CS patients over 3 years, which was significantly higher in patients implanted with an ILR within 2 months after stroke than those implanted later. Conclusions: The expanded coverage policy for CS had a significant impact on the number of ILR implantation for CS indication. The diagnostic yield of ILR for AF/AFL detection seems better when ILR is implanted within 2 months than later. Further investigation is needed to demonstrate other clinical benefits and the optimal ILR implantation timing.

참고문헌 (19)

  1. Edvardsson N, "Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope : results from the PICTURE registry", Europace, 13, pp.262~269 (2011)
  2. Lacunza-Ruiz FJ, "Implantable loop recorder allows an etiologic diagnosis in onethird of patients. Results of the Spanish reveal registry", Circ J, 77, pp.2535~2541 (2013)
  3. Buck BH, "Effect of implantable vs prolonged external electrocardiographic monitoring on atrial fibrillation detection in patients with ischemic stroke : the PER DIEM randomized clinical trial", JAMA, 325, pp.2160~2168 (2021)
  4. Sanna T, "Cryptogenic stroke and underlying atrial fibrillation", N Engl J Med, 370, pp.2478~2486 (2014)
  5. Kim HK, "Data configuration and publication trends for the Korean National Health Insurance and Health Insurance Review & Assessment database", Diabetes Metab J, 44, pp.671~678 (2020)
  6. Tsivgoulis G, "Prolonged cardiac rhythm monitoring and secondary stroke prevention in patients with cryptogenic cerebral ischemia", Stroke, 50, pp.2175~2180 (2019)
  7. Huang WY, "Association between implantable loop recorder use and secondary stroke prevention : a meta-analysis", Open Heart, 9, pp.e002034~ (2022)
  8. Jiang H, "A meta-analysis of extended ECG monitoring in detection of atrial fibrillation in patients with cryptogenic stroke", Open Heart, 9, pp.e002081~ (2022)
  9. Skrebelyte-Strøm L, "Prediction of occult atrial fibrillation in patients after cryptogenic stroke and transient ischaemic attack : PROACTIA", Europace, 24, pp.1881~1888 (2022)
  10. Kim JG, "Impact of neuroimaging patterns for the detection of atrial fibrillation by implantable loop recorders in patients with embolic stroke of undetermined source", Front Neurol, 13, pp.905998~ (2022)
  11. Ahluwalia N, "Contemporary practice and optimising referral pathways for implantable cardiac monitoring for atrial fibrillation after cryptogenic stroke", J Stroke Cerebrovasc Dis, 31, pp.106474~ (2022)
  12. Samaan S, "Detection of atrial fibrillation by implantable loop recorders following cryptogenic stroke : a retrospective study of predictive factors and outcomes", J Electrocardiol, 71, pp.54~58 (2022)
  13. Dulai R, "Immediate implantable loop recorder implantation for detecting atrial fibrillation in cryptogenic stroke", J Stroke Cerebrovasc Dis, 32, pp.106988~ (2023)
  14. Navi BB, "Cryptogenic subtype predicts reduced survival among cancer patients with ischemic stroke", Stroke, 45, pp.2292~2297 (2014)
  15. Arboix A, "Cardioembolic stroke : clinical features, specific cardiac disorders and prognosis", Curr Cardiol Rev, 6, pp.150~161 (2010)
  16. Stöllberger C, "Detection of paroxysmal atrial fibrillation and patent foramen ovale in cryptogenic stroke", Eur J Neurol, 16, pp.160~161 (2009)
  17. Hart RG, "Embolic strokes of undetermined source : the case for a new clinical construct", Lancet Neurol, 13, pp.429~438 (2014)
  18. Katsanos AH, "The value of transesophageal echocardiography for embolic strokes of undetermined source", Neurology, 87, pp.988~995 (2016)
  19. Bettin M, "Extended ECG monitoring with an implantable loop recorder in patients with cryptogenic stroke : time schedule, reasons for explantation and incidental findings(results from the TRACK-AF trial)", Clin Res Cardiol, 108, pp.309~314 (2019)

관련 논문AI추천

Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-AnalysisAndrei V. Alexandrov, Anne W. Alexandrov, Aristeidis H. Katsanos, Christos Krogias, Dimitris Mavridis, Fabienne Perren, Georgios Tsivgoulis, John Ellul, Lina Palaiodimou, Martin Köhrmann, Peter D. Schellinger, Sokratis Triantafyllou, Sotirios Giannopoulos, Spyridon Deftereos, Valeria Caso대한뇌졸중학회 · 대한뇌졸중영문학회지2019 · 제21권 제3호Detection rate by time period and predictors of serious arrhythmias in unexplained syncope: a multicenter implantable loop recorder registry studyHong Euy Lim, Hyoung-Seob Park, Il-Young Oh, Jaemin Shim, Jae-Sun Uhm, Jinhee Ahn, Jumsuk Ko, Junbeom Park, Jun Hyung Kim, Juwon Kim, Ju Youn Kim, Ki-Hun Kim, Myung-Jin Cha, Pil-Sung Yang, So-Ryoung Lee, Sung Ho Lee대한내과학회 · The Korean Journal of Internal Medicine2025 · 제40권 제4호How and When to Screen for Atrial Fibrillation after Stroke: Insights from Insertable Cardiac Monitoring DevicesFrancesca Bridge, Vincent Thijs대한뇌졸중학회 · 대한뇌졸중영문학회지2016 · 제18권 제2호Efficacy and Safety Outcomes of Catheter Ablation of Non-valvular Atrial Fibrillation in Korean Practice: Analysis of Nationwide Claims Data노태호, 오용석, 이만영, 장성원, Gi-Hyeon Seo대한부정맥학회 · International Journal of Arrhythmia2018 · 제19권 제1호Comparative occurrence of ischemic stroke with the rhythm versus rate control strategy in a national prospective cohort of atrial fibrillationBoyoung Joung, Changsoo Kim, Eue-Keun Choi, Hyung Wook Park, Jae Guk Kim, Jaemin Shim, Jae-Sun Uhm, Jin-Bae Kim, Jin-Kyu Park, Junbeom Park, Jung Myung Lee, Jun Kim, Ki-Woon Kang, Myung-Jin Cha, Tae-Hoon Kim, Young Soo Lee대한내과학회 · The Korean Journal of Internal Medicine2021 · 제36권 제1호Left Atrial Diameter and Atrial Ectopic Burden in Patients with Embolic Stroke of Undetermined Source: Risk Stratification of Atrial Fibrillation with Insertable Cardiac Monitor Analysis강지훈, 김범준, 김준엽, 문인태, 배희준, 오일영, 이지현, 조용진, 한문구대한신경과학회 · Journal of Clinical Neurology2021 · 제17권 제2호

이 간행물의 다른 논문 (18건)