Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류재활의학

초록

Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer.Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35o angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength.

Abstract

Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer.Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35o angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength.

참고문헌 (26)

  1. Bean JF, "The relationship between leg power and physical performance in mobility-limited older people", J Am Geriatr Soc, 50, pp.461~467 (2002)
  2. Suzuki T, "Muscle power of the ankle flexors predicts functional performance in community-dwelling older women", J Am Geriatr Soc, 49, pp.1161~1167 (2001)
  3. Lauretani F, "Age-associated changes in skeletal muscles and their effect on mobility: an operational diagnosis of sarcopenia", J Appl Physiol, 95, pp.1851~1860 (2003)
  4. Al Snih S, "Hand grip strength and incident ADL disability in elderly Mexican Americans over a seven-year period", Aging Clin Exp Res, 16, pp.481~486 (2004)
  5. Brinker MR, "An examination of bias in shoulder scoring instruments among healthy collegiate and recreational athletes", J Shoulder Elbow Surg, 11, pp.463~469 (2002)
  6. Incel NA, "Grip strength: effect of hand dominance", Singapore Med J, 43, pp.234~237 (2002)
  7. Knapik JJ, "Isokinetic, isometric and isotonic strength relationships", Arch Phys Med Rehabil, 64, pp.77~80 (1983)
  8. Farrell M, "Analysis of the reliability and validity of the kinetic communicator exercise device", Med Sci Sports Exerc, 18, pp.44~49 (1986)
  9. Drouin JM, "Reliability and validity of the Biodex System 3 Pro isokinetic dynamometer velocity, torque and position measurements", Eur J Appl Physiol, 91, pp.22~29 (2004)
  10. Feiring DC, "Test-retest reliability of the Biodex isokinetic dynamometer", J Orthop Sports Phys Ther, 11, pp.298~300 (1990)
  11. Toonstra J, "Test-retest reliability and validity of isometric knee flexion and extension measurement using three methods of assessing muscle strength", J Sport Rehabil (2012)
  12. Scott DA, "The intraand interrater reliability of hip muscle strength assessments using a handheld versus a portable dynamometer anchoring station", Arch Phys Med Rehabil, 85, pp.598~603 (2004)
  13. Kollock RO Jr, "The reliability of portable fixed dynamometry during hip and knee strength assessments", J Athl Train, 45, pp.349~356 (2010)
  14. Keating JL, "The influence of subject and test design on dynamometric measurements of extremity muscles", Phys Ther, 76, pp.866~889 (1996)
  15. Stark T, "Handheld dynamometry correlation with the gold standard isokinetic dynamometry: a systematic review", PM R, 3, pp.472~479 (2011)
  16. Thorborg K, "Hip- and kneestrength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable", Knee Surg Sports Traumatol Arthrosc, 21, pp.550~555 (2013)
  17. Woods S, "The effects of rest interval length on ratings of perceived exertion during dynamic knee extension exercise", J Strength Cond Res, 18, pp.540~545 (2004)
  18. Maffiuletti NA, "Quadriceps femoris torque and EMG activity in seated versus supine position", Med Sci Sports Exerc, 35, pp.1511~1516 (2003)
  19. Walsworth M, "Prediction of 10 repetition maximum for short-arc quadriceps exercise from handheld dynamometer and anthropometric measurements", J Orthop Sports Phys Ther, 28, pp.97~104 (1998)
  20. Knapik JJ, "Isometric, isotonic, and isokinetic torque variations in four muscle groups through a range of joint motion", Phys Ther, 63, pp.938~947 (1983)
  21. Stratford PW, "A comparison of make and break tests using a hand-held dynamometer and the Kin-Com", J Orthop Sports Phys Ther, 19, pp.28~32 (1994)
  22. Deones VL, "Assessment of quadriceps muscle performance by a hand-held dynamometer and an isokinetic dynamometer", J Orthop Sports Phys Ther, 20, pp.296~301 (1994)
  23. Taylor JR, "An introduction to error analysis: the study of uncertainties in physical measurements", pp.1999
  24. Visser JJ, "Length and moment arm of human leg muscles as a function of knee and hip-joint angles", Eur J Appl Physiol Occup Physiol, 61, pp.453~460 (1990)
  25. Babault N, "Effect of quadriceps femoris muscle length on neural activation during isometric and concentric contractions", J Appl Physiol, 94, pp.983~990 (2003)
  26. Martin HJ, "Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard Biodex dynamometry", Gerontology, 52, pp.154~159 (2006)

관련 논문AI추천

이 간행물의 다른 논문 (20건)