Effects of Very High Stimulation Frequency and Wide-Pulse Duration on Stimulated Force and Fatigue of Quadriceps in Healthy Participants
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective To determine the effect of very high stimulation frequency (150 and 200 Hz) with wide pulse duration versus 50 Hz with wide pulse duration on stimulated force and fatigue of quadriceps femoris in healthy participants. Methods Thirty-four healthy participants underwent fatigue test using three stimulation frequency conditions (50, 150, and 200 Hz) with pulse duration of 0.9 ms. Normalized force values at the end of each fatigue protocol and curve fitting patterns were compared among stimulated frequencies. Results Very high stimulation frequency (150 and 200 Hz) conditions showed a trend of having more decline in normalized stimulated force during fatigue test compared to a low stimulation frequency at 50 Hz. However, the difference was not statistically significant. Responder group showed the same slope of a linear fitting pattern, implying the same pattern of muscle fatigue among three stimulation frequency conditions (-3.32 in 50 Hz, -2.88 in 150 Hz, and -3.14 in 200 Hz, respectively). Conclusion There were high inter-subject variations in the response to different frequency stimulation conditions. However, very high stimulation frequency generated the same fatigue pattern as the low stimulation frequency in the responder group. Further research is needed to explore the mechanism involved.
Abstract
Objective To determine the effect of very high stimulation frequency (150 and 200 Hz) with wide pulse duration versus 50 Hz with wide pulse duration on stimulated force and fatigue of quadriceps femoris in healthy participants. Methods Thirty-four healthy participants underwent fatigue test using three stimulation frequency conditions (50, 150, and 200 Hz) with pulse duration of 0.9 ms. Normalized force values at the end of each fatigue protocol and curve fitting patterns were compared among stimulated frequencies. Results Very high stimulation frequency (150 and 200 Hz) conditions showed a trend of having more decline in normalized stimulated force during fatigue test compared to a low stimulation frequency at 50 Hz. However, the difference was not statistically significant. Responder group showed the same slope of a linear fitting pattern, implying the same pattern of muscle fatigue among three stimulation frequency conditions (-3.32 in 50 Hz, -2.88 in 150 Hz, and -3.14 in 200 Hz, respectively). Conclusion There were high inter-subject variations in the response to different frequency stimulation conditions. However, very high stimulation frequency generated the same fatigue pattern as the low stimulation frequency in the responder group. Further research is needed to explore the mechanism involved.
참고문헌 (39)
- Glanz M, "Functional electrostimulation in poststroke rehabilitation: a meta-analysis of the randomized controlled trials", Arch Phys Med Rehabil, 77, pp.549~553 (1996)[DOI]
- Yan T, "Functional electrical stimulation improves motor recovery of the lower extremity and walking ability of subjects with first acute stroke: a randomized placebo-controlled trial", Stroke, 36, pp.80~85 (2005)[DOI]
- Currier DP, "Muscular strength development by electrical stimulation in healthy individuals", Phys Ther, 63, pp.915~921 (1983)[DOI]
- Laughman RK, "Strength changes in the normal quadriceps femoris muscle as a result of electrical stimulation", Phys Ther, 63, pp.494~499 (1983)[DOI]
- Gorgey AS, "Effects of neuromuscular electrical stimulation parameters on specific tension", Eur J Appl Physiol, 97, pp.737~744 (2006)[DOI]
- Gregory CM, "Impact of varying pulse frequency and duration on muscle torque production and fatigue", Muscle Nerve, 35, pp.504~509 (2007)[DOI]
- Dreibati B, "Influence of electrical stimulation frequency on skeletal muscle force and fatigue", Ann Phys Rehabil Med, 53, pp.266~271 (2010)[DOI]
- Kesar T, "Effect of frequency and pulse duration on human muscle fatigue during repetitive electrical stimulation", Exp Physiol, 91, pp.967~976 (2006)[DOI]
- Van Cutsem M, "Changes in single motor unit behavior contribute to the increase in contraction speed after dynamic training in humans", J Physiol, 513, pp.295~305 (1998)[DOI]
- Christie A, "Doublet discharges in motoneurons of young and older adults", J Neurophysiol, 95, pp.2787~2795 (2006)[DOI]
- Abbate F, "Effects of high-frequency initial pulses and posttetanic potentiation on power output of skeletal muscle", J Appl Physiol (1985), 88, pp.35~40 (2000)[DOI]
- Malesevic NM, "Distributed low-frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation", Muscle Nerve, 42, pp.556~562 (2010)[DOI]
- Popovic LZ, "Muscle fatigue of quadriceps in paraplegics: comparison between single vs. multi-pad electrode surface stimulation", Conf Proc IEEE Eng Med Biol Soc, 2009, pp.6785~6788 (2009)
- Bergquist AJ, "Motor unit recruitment when neuromuscular electrical stimulation is applied over a nerve trunk compared with a muscle belly: quadriceps femoris", J Appl Physiol (1985), 113, pp.78~89 (2012)[DOI]
- Knikou M, "The H-reflex as a probe: pathways and pitfalls", J Neurosci Methods, 171, pp.1~12 (2008)[DOI]
- Misiaszek JE, "The H-reflex as a tool in neurophysiology: its limitations and uses in understanding nervous system function", Muscle Nerve, 28, pp.144~160 (2003)[DOI]
- Dideriksen JL, "Physiological recruitment of motor units by highfrequency electrical stimulation of afferent pathways", J Appl Physiol (1985), 118, pp.365~376 (2015)[DOI]
- Dean JC, "Turning on the central contribution to contractions evoked by neuromuscular electrical stimulation", J Appl Physiol (1985), 103, pp.170~176 (2007)[DOI]
- Clair-Auger JM, "The effects of wide pulse neuromuscular electrical stimulation on elbow flexion torque in individuals with chronic hemiparetic stroke", Clin Neurophysiol, 123, pp.2247~2255 (2012)[DOI]
- Binder-Macleod SA, "Comparison of fatigue produced by various electrical stimulation trains", Acta Physiol Scand, 172, pp.195~203 (2001)[DOI]
- Guyton AC, "Textbook of medical physiology. 11th ed" (2006), Elsevier Saunders
- Borg J, "Refractory period of single motor nerve fibres in man", J Neurol Neurosurg Psychiatry, 47, pp.344~348 (1984)[DOI]
- Kimura J, "Refractory period of human motor nerve fibres", J Neurol Neurosurg Psychiatry, 41, pp.784~790 (1978)[DOI]
- Willems ME, "Divergent muscle fatigue during unilateral isometric contractions of dominant and non-dominant quadriceps", J Sci Med Sport, 16, pp.240~244 (2013)[DOI]
- Neyroud D, "Wide-pulse-high-frequency neuromuscular stimulation of triceps surae induces greater muscle fatigue compared with conventional stimulation", J Appl Physiol (1985), 116, pp.1281~1289 (2014)[DOI]
- Oyewole SA, "Enhancing ergonomic safety effectiveness of repetitive job activities: prediction of muscle fatigue in dominant and nondominant arms of industrial workers", Hum Factors Ergon Manuf Serv Ind, 24, pp.585~600 (2014)[DOI]
- Adams GR, "Mapping of electrical muscle stimulation using MRI", J Appl Physiol (1985), 74, pp.532~537 (1993)[DOI]
- Wegrzyk J, "Extra Forces induced by widepulse, high-frequency electrical stimulation: occurrence, magnitude, variability and underlying mechanisms", Clin Neurophysiol, 126, pp.1400~1412 (2015)[DOI]
- Papaiordanidou M, "Electrically induced torque decrease reflects more than muscle fatigue", Muscle Nerve, 50, pp.604~607 (2014)[DOI]
- Martin A, "The etiology of muscle fatigue differs between two electrical stimulation protocols", Med Sci Sports Exerc, 48, pp.1474~1484 (2016)[DOI]
- Baldwin ER, "Wide-pulsewidth, high-frequency neuromuscular stimulation: implications for functional electrical stimulation", J Appl Physiol (1985), 101, pp.228~240 (2006)[DOI]
- Collins DF, "Central contributions to contractions evoked by tetanic neuromuscular electrical stimulation", Exerc Sport Sci Rev, 35, pp.102~109 (2007)
- Wegrzyk J, "Responders to wide-pulse, highfrequency neuromuscular electrical stimulation show reduced metabolic demand: a 31P-MRS study in humans", PLoS One, 10, pp.e0143972~ (2015)[DOI]
- Russ DW, "Effects of muscle activation on fatigue and metabolism in human skeletal muscle", J Appl Physiol (1985), 92, pp.1978~1986 (2002)[DOI]
- Matsunaga T, "Muscle fatigue from intermittent stimulation with low and high frequency electrical pulses", Arch Phys Med Rehabil, 80, pp.48~53 (1999)[DOI]
- Kesar T, "Effects of stimulation frequency versus pulse duration modulation on muscle fatigue", J Electromyogr Kinesiol, 18, pp.662~671 (2008)[DOI]
- Jorgensen L, "Changes in muscle mass, fat mass, and bone mineral content in the legs after stroke: a 1 year prospective study", Bone, 28, pp.655~659 (2001)[DOI]
- Hafer-Macko CE, "Skeletal muscle changes after hemiparetic stroke and potential beneficial effects of exercise intervention strategies", J Rehabil Res Dev, 45, pp.261~272 (2008)[DOI]
- Severinsen K, "Skeletal muscle fiber characteristics and oxidative capacity in hemiparetic stroke survivors", Muscle Nerve, 53, pp.748~754 (2016)[DOI]