본문 바로가기
KERD
논문KCI 등재

Can a Biomechanical Foot Orthosis Affect Gait in Patients With Hallux Valgus? A Pilot Study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류재활의학

초록

Objective To investigate the effects of customized biomechanical foot orthosis (BFO) on kinematic data during gait in patients with hallux valgus (HV) deformities and compare the results with those of a normal control group.Methods Ten patients with HV deformities and 10 healthy volunteers were enrolled in this study. HV deformity was diagnosed using biomechanical and radiological assessments by a rehabilitation physician. Patients received the customized BFO manufactured at a commercial orthosis laboratory (Biomechanics, Goyang, South Korea) according to the strictly defined procedure by a single experienced technician. The spatiotemporal and kinematic data acquired by the Vicon 3D motion capture system (Oxford Metrics, Oxford, UK) were compared between the intervention groups (control vs. HV without orthosis) and between the HV groups (with vs. without orthosis).Results The temporal-spatial and kinematic parameters of the HV group were significantly different from those of the control group. After applying BFO to the HV group, significantly increased ranges of plantar flexion motion and hindfoot inversion were observed. Furthermore, the HV group with BFO showed improved gait cadence, walking speed, and stride length, although the results were not statistically significant.Conclusion Our results suggest that it is imperative to understand the pathophysiology of HV, and the application of customized BFO can be useful for improving kinematics in HV deformities.

Abstract

Objective To investigate the effects of customized biomechanical foot orthosis (BFO) on kinematic data during gait in patients with hallux valgus (HV) deformities and compare the results with those of a normal control group.Methods Ten patients with HV deformities and 10 healthy volunteers were enrolled in this study. HV deformity was diagnosed using biomechanical and radiological assessments by a rehabilitation physician. Patients received the customized BFO manufactured at a commercial orthosis laboratory (Biomechanics, Goyang, South Korea) according to the strictly defined procedure by a single experienced technician. The spatiotemporal and kinematic data acquired by the Vicon 3D motion capture system (Oxford Metrics, Oxford, UK) were compared between the intervention groups (control vs. HV without orthosis) and between the HV groups (with vs. without orthosis).Results The temporal-spatial and kinematic parameters of the HV group were significantly different from those of the control group. After applying BFO to the HV group, significantly increased ranges of plantar flexion motion and hindfoot inversion were observed. Furthermore, the HV group with BFO showed improved gait cadence, walking speed, and stride length, although the results were not statistically significant.Conclusion Our results suggest that it is imperative to understand the pathophysiology of HV, and the application of customized BFO can be useful for improving kinematics in HV deformities.

참고문헌 (20)

  1. Nix SE, "Gait parameters associated with hallux valgus : a systematic review", J Foot Ankle Res, 6, pp.9~ (2013)
  2. Adams PF, "Current estimates from the National Health Interview Survey, 1996", Vital Health Stat 10, (200), pp.1~203 (1999)
  3. Nix S, "Prevalence of hallux valgus in the general population : a systematic review and meta-analysis", J Foot Ankle Res, 3, pp.21~ (2010)
  4. 장규선, "무지 외반증의 진단 및 병태생리", 대한족부족관절학회지, 18(2), pp.43~47 (2014), 대한족부족관절학회[DOI]
  5. Shih KS, "Gait changes in individuals with bilateral hallux valgus reduce first metatarsophalangeal loading but increase knee abductor moments", Gait Posture, 40, pp.38~42 (2014)
  6. Menz HB, "Gait instability in older people with hallux valgus", Foot Ankle Int, 26, pp.483~489 (2005)
  7. Torkki M, "Surgery vs orthosis vs watchful waiting for hallux valgus : a randomized controlled trial", JAMA, 285, pp.2474~2480 (2001)
  8. Klugarova J, "Hallux valgus surgery affects kinematic parameters during gait", Clin Biomech(Bristol, Avon), 40, pp.20~26 (2016)
  9. 이성현, "무지 외반증의 치료에 대한 고찰", 대한족부족관절학회지, 23(4), pp.143~148 (2019), 대한족부족관절학회[DOI]
  10. Charrette M, "Bunion formation and orthotic support", Dyn Chiropr, 27, pp.1~3 (2009)
  11. Kwan MY, "Hallux valgus orthosis characteristics and effectiveness : a systematic review with meta-analysis", BMJ Open, 11, pp.e047273~ (2021)
  12. Deschamps K, "The impact of hallux valgus on foot kinematics : a cross-sectional, comparative study", Gait Posture, 32, pp.102~106 (2010)
  13. Stebbins J, "Repeatability of a model for measuring multi-segment foot kinematics in children", Gait Posture, 23, pp.401~410 (2006)
  14. Root ML, "Neutral position casting techniques" (1971), Clinical Biomechanics Corporation
  15. Hamacher D, "Kinematic measures for assessing gait stability in elderly individuals : a systematic review", J R Soc Interface, 8, pp.1682~1698 (2011)
  16. Canseco K, "Quantitative characterization of gait kinematics in patients with hallux rigidus using the Milwaukee foot model", J Orthop Res, 26, pp.419~427 (2008)
  17. Canseco K, "Motion of the multisegmental foot in hallux valgus", Foot Ankle Int, 31, pp.146~152 (2010)
  18. Chopra S, "Characterization of gait in female patients with moderate to severe hallux valgus deformity", Clin Biomech(Bristol, Avon), 30, pp.629~635 (2015)
  19. Becerro de Bengoa Vallejo R, "Clinical improvement in functional hallux limitus using a cut-out orthosis", Prosthet Orthot Int, 40, pp.215~223 (2016)
  20. Callisaya ML, "Ageing and gait variability : a populationbased study of older people", Age Ageing, 39, pp.191~197 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (5건)