Impact of Afterload on the Assessment of Severity of Aortic Stenosis
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background: Aortic stenosis (AS) is increasingly diagnosed in current aging society. Echocardiography is the most important tool in the assessment of AS and its severity. However, load-dependency of Doppler measurement could affect the accuracy of AS severity assessment. We tried to evaluate the impact of afterload on the assessment of AS severity by modification of afterload using pneumatic compression (Pcom). Methods: Forty patients diagnosed as moderate or severe AS [effective orifice area of aortic valve (EOAAV) by continuity equation of < 1.5 cm2] were consecutively enrolled. Patients with severely uncontrolled hypertension, severe left ventricular (LV)dysfunction, and other significant valve disease were excluded. Comprehensive echocardiography was performed at baseline to assess AS severity. Then, pneumatic compression of the lower extremities by 100 mmHg was applied to increase LV afterload. After 3 minutes, echocardiography was repeated to assess AS severity. Results: Mean blood pressure was significantly increased under Pcom (p < 0.001), while heart rate remained unchanged. Peak aortic valve velocity (Vmax) was slightly, but significantly decreased under Pcom (p = 0.03). However, Doppler velocity index and EOAAV by continuity equation were not affected by Pcom. Conclusion: AS severity assessment by echocardiography was not dependent on the change of LV afterload imposed by Pcom. AV Vmax was slightly decreased with LV afterload increment, but these changes were too small to alter treatment plan of AS patients. EOAAV and Doppler velocity index are more stable parameters for AS severity assessment.
Abstract
Background: Aortic stenosis (AS) is increasingly diagnosed in current aging society. Echocardiography is the most important tool in the assessment of AS and its severity. However, load-dependency of Doppler measurement could affect the accuracy of AS severity assessment. We tried to evaluate the impact of afterload on the assessment of AS severity by modification of afterload using pneumatic compression (Pcom). Methods: Forty patients diagnosed as moderate or severe AS [effective orifice area of aortic valve (EOAAV) by continuity equation of < 1.5 cm2] were consecutively enrolled. Patients with severely uncontrolled hypertension, severe left ventricular (LV)dysfunction, and other significant valve disease were excluded. Comprehensive echocardiography was performed at baseline to assess AS severity. Then, pneumatic compression of the lower extremities by 100 mmHg was applied to increase LV afterload. After 3 minutes, echocardiography was repeated to assess AS severity. Results: Mean blood pressure was significantly increased under Pcom (p < 0.001), while heart rate remained unchanged. Peak aortic valve velocity (Vmax) was slightly, but significantly decreased under Pcom (p = 0.03). However, Doppler velocity index and EOAAV by continuity equation were not affected by Pcom. Conclusion: AS severity assessment by echocardiography was not dependent on the change of LV afterload imposed by Pcom. AV Vmax was slightly decreased with LV afterload increment, but these changes were too small to alter treatment plan of AS patients. EOAAV and Doppler velocity index are more stable parameters for AS severity assessment.
참고문헌 (15)
- Faggiano P, "Epidemiology and cardiovascular risk factors of aortic stenosis", Cardiovasc Ultrasound, 4, pp.27~ (2006)
- Lindroos M, "Prevalence of aortic valve abnormalities in the elderly: an echocardiographic study of a random population sample", J Am Coll Cardiol, 21, pp.1220~1225 (1993)
- Chambers J, "Can high blood pressure mask severe aortic stenosis?", J Heart Valve Dis, 8, pp.277~278 (1999)
- Hachicha Z, "Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival", Circulation, 115, pp.2856~2864 (2007)
- Antonini-Canterin F, "Symptomatic aortic stenosis: does systemic hypertension play an additional role?", Hypertension, 41, pp.1268~1272 (2003)
- Park HE, "Impact of loading condition on the 2D speckle tracking-derived left ventricular dyssynchrony index in nonischemic dilated cardiomyopathy", Circ Cardiovasc Imaging, 3, pp.272~281 (2010)
- Otto CM, "Determination of the stenotic aortic valve area in adults using Doppler echocardiography", J Am Coll Cardiol, 7, pp.509~517 (1988)
- Ihlen H, "Determination of cardiac output by Doppler echocardiography", Br Heart J, 51, pp.54~60 (1984)
- Mascherbauer J, "Systemic pressure does not directly affect pressure gradient and valve area estimates in aortic stenosis in vitro", Eur Heart J, 29, pp.2049~2057 (2008)
- Thubrikar M, "The mechanism of opening of the aortic valve", J Thorac Cardiovasc Surg, 77, pp.863~870 (1979)
- Higashidate M, "Regulation of the aortic valve opening. In vivo dynamic measurement of aortic valve orifice area", J Thorac Cardiovasc Surg, 110, pp.496~503 (1995)
- Little SH, "Impact of blood pressure on the Doppler echocardiographic assessment of severity of aortic stenosis", Heart, 93, pp.848~855 (2007)
- Rubal BJ, "Effects of pneumatic antishock garment inflation in normovolemic subjects", J Appl Physiol, 67, pp.339~345 (1989)
- Abbas AE, "Noninvasive measurement of systemic vascular resistance using Doppler echocardiography", J Am Soc Echocardiogr, 17, pp.834~838 (2004)
- Chemla D, "Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans", Am J Physiol, 274, pp.500~505 (1998)
