Automated Quantification of Mitral Regurgitation by Three Dimensional Real Time Full Volume Color Doppler Transthoracic Echocardiography: A Validation With Cardiac Magnetic Resonance Imaging and Comparison With Two Dimensional Quantitative Methods
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background: Accurate assessment of mitral regurgitation (MR) severity is crucial for clinical decision-making and optimizing patient outcomes. Recent advances in real-time three dimensional (3D) echocardiography provide the option of real-time full volume color Doppler echocardiography (FVCD) measurements. This makes it practical to quantify MR by subtracting aortic stroke volume from the volume of mitral inflow in an automated manner. Methods: Thirty-two patients with more than a moderate degree of MR assessed by transthoracic echocardiography (TTE)were consecutively enrolled during this study. MR volume was measured by 1) two dimensional (2D) Doppler TTE, using the proximal isovelocity surface area (PISA) and the volumetric quantification methods (VM). Then, 2) real time 3D-FVCD was subsequently obtained, and dedicated software was used to quantify the MR volume. MR volume was also measured using 3)phase contrast cardiac magnetic resonance imaging (PC-CMR). In each patient, all these measurements were obtained within the same day. Automated MR quantification was feasible in 30 of 32 patients. Results: The mean regurgitant volume quantified by 2D-PISA, 2D-VM, 3D-FVCD, and PC-CMR was 72.1 ± 27.7, 79.9 ±36.9, 69.9 ± 31.5, and 64.2 ± 30.7 mL, respectively (p = 0.304). There was an excellent correlation between the MR volume measured by PC-CMR and 3D-FVCD (r = 0.85, 95% CI 0.70-0.93, p < 0.001). Compared with PC-CMR, Bland-Altman analysis for 3D-FVCD showed a good agreement (2 standard deviations: 34.3 mL) than did 2D-PISA or 2D-VM (60.0 and 62.8mL, respectively). Conclusion: Automated quantification of MR with 3D-FVCD is feasible and accurate. It is a promising tool for the real-time 3D echocardiographic assessment of patients with MR.
Abstract
Background: Accurate assessment of mitral regurgitation (MR) severity is crucial for clinical decision-making and optimizing patient outcomes. Recent advances in real-time three dimensional (3D) echocardiography provide the option of real-time full volume color Doppler echocardiography (FVCD) measurements. This makes it practical to quantify MR by subtracting aortic stroke volume from the volume of mitral inflow in an automated manner. Methods: Thirty-two patients with more than a moderate degree of MR assessed by transthoracic echocardiography (TTE)were consecutively enrolled during this study. MR volume was measured by 1) two dimensional (2D) Doppler TTE, using the proximal isovelocity surface area (PISA) and the volumetric quantification methods (VM). Then, 2) real time 3D-FVCD was subsequently obtained, and dedicated software was used to quantify the MR volume. MR volume was also measured using 3)phase contrast cardiac magnetic resonance imaging (PC-CMR). In each patient, all these measurements were obtained within the same day. Automated MR quantification was feasible in 30 of 32 patients. Results: The mean regurgitant volume quantified by 2D-PISA, 2D-VM, 3D-FVCD, and PC-CMR was 72.1 ± 27.7, 79.9 ±36.9, 69.9 ± 31.5, and 64.2 ± 30.7 mL, respectively (p = 0.304). There was an excellent correlation between the MR volume measured by PC-CMR and 3D-FVCD (r = 0.85, 95% CI 0.70-0.93, p < 0.001). Compared with PC-CMR, Bland-Altman analysis for 3D-FVCD showed a good agreement (2 standard deviations: 34.3 mL) than did 2D-PISA or 2D-VM (60.0 and 62.8mL, respectively). Conclusion: Automated quantification of MR with 3D-FVCD is feasible and accurate. It is a promising tool for the real-time 3D echocardiographic assessment of patients with MR.
참고문헌 (25)
- Enriquez-Sarano M, "Mitral regurgitation", Lancet, 373, pp.1382~1394 (2009)
- Zoghbi WA, "American Society of Echocardiography. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography", J Am Soc Echocardiogr, 16, pp.777~802 (2003)
- Enriquez-Sarano M, "Quantitative determinants of the outcome of asymptomatic mitral regurgitation", N Engl J Med, 352, pp.875~883 (2005)
- Enriquez-Sarano M, "Valve repair improves the outcome of surgery for mitral regurgitation. A multivariate analysis", Circulation, 91, pp.1022~1028 (1995)
- Enriquez-Sarano M, "Quantitation of mitral regurgitation: rationale, approach, and interpretation in clinical practice", Heart, 88(Suppl 4), pp.iv1~iv3 (2002)
- American College of Cardiology, "ACC", AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology, J Am Coll Cardiol, pp.2006, 48[DOI]
- Buck T, "Effect of dynamic flow rate and orifice area on mitral regurgitant stroke volume quantification using the proximal isovelocity surface area method", J Am Coll Cardiol, 52, pp.767~778 (2008)
- Yosefy C, "Proximal flow convergence region as assessed by real-time 3-dimensional echocardiography: challenging the hemispheric assumption", J Am Soc Echocardiogr, 20, pp.389~396 (2007)
- Ge S, "A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: a validation study compared with magnetic resonance imaging", J Am Soc Echocardiogr, 18, pp.1~7 (2005)
- Lodato JA, "Use of 3-dimensional color Doppler echocardiography to measure stroke volume in human beings: comparison with thermodilution", J Am Soc Echocardiogr, 20, pp.103~112 (2007)
- Pemberton J, "The use of live three-dimensional Doppler echocardiography in the measurement of cardiac output: an in vivo animal study", J Am Coll Cardiol, 45, pp.433~438 (2005)
- Thavendiranathan P, "Automated quantification of mitral inflow and aortic outflow stroke volumes by threedimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging", J Am Soc Echocardiogr, 25, pp.56~65 (2012)
- Shanks M, "Quantitative assessment of mitral regurgitation: comparison between three-dimensional transesophageal echocardiography and magnetic resonance imaging", Circ Cardiovasc Imaging, 3, pp.694~700 (2010)
- Lang RM, "Chamber Quantification Writing Group; American Society of Echocardiography’s Guidelines and Standards Committee; European Association of Echocardiography. Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology", J Am Soc Echocardiogr, 18, pp.1440~1463 (2005)
- Rokey R, "Determination of regurgitant fraction in isolated mitral or aortic regurgitation by pulsed Doppler two-dimensional echocardiography", J Am Coll Cardiol, 7, pp.1273~1278 (1986)
- Enriquez-Sarano M, "Mays JM. Quantitative Doppler assessment of valvular regurgitation", Circulation, 87, pp.841~848 (1993)
- Wang Y, "Automatic cardiac flow quantification on 3D volume color Doppler data", IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp.1688~1691 (2011), IEEE
- Zheng Y, "Four-chamber heart modeling and automatic segmentation for 3-D cardiac CT volumes using marginal space learning and steerable features", IEEE Trans Med Imaging, 27, pp.1668~1681 (2008)
- Matthews F, "A novel operator-independent algorithm for cardiac output measurements based on three-dimensional transoesophageal colour Doppler echocardiography", Eur J Echocardiogr, 11, pp.432~437 (2010)
- Pu M, "Calculation of mitral regurgitant orifice area with use of a simplified proximal convergence method: initial clinical application", J Am Soc Echocardiogr, 14, pp.180~185 (2001)
- Enriquez-Sarano M, "Effective mitral regurgitant orifice area: clinical use and pitfalls of the proximal isovelocity surface area method", J Am Coll Cardiol, 25, pp.703~709 (1995)
- de Agustín JA, "Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study", J Am Soc Echocardiogr, 25, pp.815~823 (2012)
- Kizilbash AM, "Comparison of quantitative Doppler with magnetic resonance imaging for assessment of the severity of mitral regurgitation", Am J Cardiol, 81, pp.792~795 (1998)
- Hundley WG, "Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques", Circulation, 92, pp.1151~1158 (1995)
- Myerson SG, "Direct and indirect quantification of mitral regurgitation with cardiovascular magnetic resonance, and the effect of heart rate variability", MAGMA, 23, pp.243~249 (2010)
