Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.
Abstract
BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.
참고문헌 (41)
- Badano LP, "Improved workflow, sonographer productivity, and costeffectiveness of echocardiographic service for inpatients by using miniaturized systems", Eur J Echocardiogr, 10, pp.537~542 (2009)
- Douglas PS, "ACCF", ASE, ASNC, pp.SCAI, SCCT[DOI]
- Popescu BA, "European Association of Echocardiography recommendations for training, competence, and quality improvement in echocardiography", Eur J Echocardiogr, 10, pp.893~905 (2009)
- Abe Y, "A novel and simple method using pocket-sized echocardiography to screen for aortic stenosis", J Am Soc Echocardiogr, 26, pp.589~596 (2013)
- Andersen GN, "Feasibility and reliability of point-of-care pocket-sized echocardiography", Eur J Echocardiogr, 12, pp.665~670 (2011)
- Brennan JM, "A comparison by medicine residents of physical examination versus hand-carried ultrasound for estimation of right atrial pressure", Am J Cardiol, 99, pp.1614~1616 (2007)
- Cardim N, "Usefulness of a new miniaturized echocardiographic system in outpatient cardiology consultations as an extension of physical examination", J Am Soc Echocardiogr, 24, pp.117~124 (2011)
- Filipiak-Strzecka D, "Pocket-size echocardiograph--a valuable tool for nonexperts or just a portable device for echocardiographers?", Adv Med Sci, 58, pp.67~72 (2013)
- Kobal SL, "Hand-carried ultrasound improves the bedside cardiovascular examination", Chest, 126, pp.693~701 (2004)
- Kono Y, "Pocket-sized echo for evaluation of mitral and tricuspid regurgitation", JACC Cardiovasc Imaging, 4, pp.921~ (2011)
- Panoulas VF, "Pocket-size hand-held cardiac ultrasound as an adjunct to clinical examination in the hands of medical students and junior doctors", Eur Heart J Cardiovasc Imaging, 14, pp.323~330 (2013)
- Vignon P, "Diagnostic ability of hand-held echocardiography in ventilated critically ill patients", Crit Care, 7, pp.R84~R91 (2003)
- Bruce CJ, "Utility of hand-carried ultrasound devices used by cardiologists with and without significant echocardiographic experience in the cardiology inpatient and outpatient settings", Am J Cardiol, 90, pp.1273~1275 (2002)
- Culp BC, "The pocket echocardiograph : validation and feasibility", Echocardiography, 27, pp.759~764 (2010)
- Decara JM, "Use of hand-carried ultrasound devices to augment the accuracy of medical student bedside cardiac diagnoses", J Am Soc Echocardiogr, 18, pp.257~263 (2005)
- Egan M, "The pocket echocardiograph : a useful new tool?", Eur J Echocardiogr, 9, pp.721~725 (2008)
- Evangelista A, "Hand-held cardiac ultrasound screening performed by family doctors with remote expert support interpretation", Heart, 102, pp.376~382 (2016)
- Frederiksen CA, "New pocket echocardiography device is interchangeable with high-end portable system when performed by experienced examiners", Acta Anaesthesiol Scand, 54, pp.1217~1223 (2010)
- Fukuda S, "Pocket-sized transthoracic echocardiography device for the measurement of cardiac chamber size and function", Circ J, 73, pp.1092~1096 (2009)
- Kimura BJ, "Hospitalist use of hand-carried ultrasound : preparing for battle", J Hosp Med, 5, pp.163~167 (2010)
- Kimura BJ, "Empowering physical examination : the"laying on"of ultrasound", JACC Cardiovasc Imaging, 1, pp.602~604 (2008)
- Kimura BJ, "Diagnostic performance of a pocketsized ultrasound device for quick-look cardiac imaging", Am J Emerg Med, 30, pp.32~36 (2012)
- Kitada R, "Diagnostic accuracy and cost-effectiveness of a pocket-sized transthoracic echocardiographic imaging device", Clin Cardiol, 36, pp.603~610 (2013)
- Labovitz AJ, "Focused cardiac ultrasound in the emergent setting : a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians", J Am Soc Echocardiogr, 23, pp.1225~1230 (2010)
- Liebo MJ, "Is pocket mobile echocardiography the next-generation stethoscope? A cross-sectional comparison of rapidly acquired images with standard transthoracic echocardiography", Ann Intern Med, 155, pp.33~38 (2011)
- Michalski B, "Diagnostic utility and clinical usefulness of the pocket echocardiographic device", Echocardiography, 29, pp.1~6 (2012)
- Mjolstad OC, "Routinely adding ultrasound examinations by pocket-sized ultrasound devices improves inpatient diagnostics in a medical department", Eur J Intern Med, 23, pp.185~191 (2012)
- Nelson BP, "Point-of-care cardiac ultrasound : feasibility of performance by noncardiologists", Glob Heart, 8, pp.293~297 (2013)
- Prinz C, "Diagnostic accuracy of a hand-held ultrasound scanner in routine patients referred for echocardiography", J Am Soc Echocardiogr, 24, pp.111~116 (2011)
- Razi R, "Bedside hand-carried ultrasound by internal medicine residents versus traditional clinical assessment for the identification of systolic dysfunction in patients admitted with decompensated heart failure", J Am Soc Echocardiogr, 24, pp.1319~1324 (2011)
- Roelandt JR, "Ultrasound stethoscopy : a renaissance of the physical examination?", Heart, 89, pp.971~973 (2003)
- Vourvouri EC, "Evaluation of a hand carried cardiac ultrasound device in an outpatient cardiology clinic", Heart, 91, pp.171~176 (2005)
- Cullen MW, "Diagnostic capability of comprehensive handheld vs transthoracic echocardiography", Mayo Clin Proc, 89, pp.790~798 (2014)
- Singh S, "American Society of Echocardiography : Remote Echocardiography with Web-Based Assessments for Referrals at a Distance(ASE-REWARD)study", J Am Soc Echocardiogr, 26, pp.221~233 (2013)
- Viera AJ, "Understanding interobserver agreement : the kappa statistic", Fam Med, 37, pp.360~363 (2005)
- Kobal SL, "Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination", Am J Cardiol, 96, pp.1002~1006 (2005)
- Galderisi M, "Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients : the NaUSiCa(Naples Ultrasound Stethoscope in Cardiology)study", Cardiovasc Ultrasound, 8, pp.51~ (2010)
- Martin LD, "Hand-carried ultrasound performed by hospitalists : does it improve the cardiac physical examination?", Am J Med, 122, pp.35~41 (2009)
- Amini R, "Point-of-care echocardiography in simulation-based education and assessment", Adv Med Educ Pract, 7, pp.325~328 (2016)
- Kennedy Hall M, "The"5Es"of emergency physician-performed focused cardiac ultrasound : a protocol for rapid identification of effusion, ejection, equality, exit, and entrance", Acad Emerg Med, 22, pp.583~593 (2015)
- Becker DM, "The use of portable ultrasound devices in low-and middle-income countries : a systematic review of the literature", Trop Med Int Health, 21, pp.294~311 (2016)