본문 바로가기
KERD
논문KCI 등재

Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, −1.42; 95% CI, −5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, −3.83; 95% CI, −9.98 to 2.32; p = 0.22), aortic SNR (mean difference, −0.23; 95% CI, −7.83 to 7.37; p = 0.95), aortic CNR (mean difference, −3.95; 95% CI, −12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, −6.09; 95% CI, −13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of −9.26 (95% CI, −15.06 to −3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.

Abstract

BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, −1.42; 95% CI, −5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, −3.83; 95% CI, −9.98 to 2.32; p = 0.22), aortic SNR (mean difference, −0.23; 95% CI, −7.83 to 7.37; p = 0.95), aortic CNR (mean difference, −3.95; 95% CI, −12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, −6.09; 95% CI, −13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of −9.26 (95% CI, −15.06 to −3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.

참고문헌 (30)

  1. Slomski A, "TAVR vs surgery in low-risk patients", JAMA, 321, pp.1965~ (2019)
  2. Achenbach S, "SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation(TAVI)", transcatheter aortic valve replacement(TAVR), 2012, pp.6, 366~380
  3. Holmes DR Jr, "2012 ACCF", AATS, STS expert consensus document on transcatheter aortic valve replacement, pp.J Am Coll Cardiol, 2012[DOI]
  4. Faggiano P, "Prevalence of comorbidities and associated cardiac diseases in patients with valve aortic stenosis. Potential implications for the decision-making process", Int J Cardiol, 159, pp.94~99 (2012)
  5. Bagur R, "Acute kidney injury following transcatheter aortic valve implantation : predictive factors, prognostic value, and comparison with surgical aortic valve replacement", Eur Heart J, 31, pp.865~874 (2010)
  6. Azzalini L, "Ultra-low contrast computed tomographic angiography(CTA)with 20-mL total dose for transcatheter aortic valve implantation(TAVI)planning", J Comput Assist Tomogr, 38, pp.105~109 (2014)
  7. Meyer M, "Closing in on the K edge : coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second-versus a third-generation dual-source CT system", Radiology, 273, pp.373~382 (2014)
  8. Page MJ, "The PRISMA 2020 statement : an updated guideline for reporting systematic reviews", BMJ, 372, pp.n71~ (2021)
  9. Higgins JP, "The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials", BMJ, 343 (2011)
  10. Sterne JA, "ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions", BMJ, 355, pp.i4919~ (2016)
  11. DerSimonian R, "Meta-analysis in clinical trials", Control Clin Trials, 7, pp.177~188 (1986)
  12. Felmly LM, "Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning", Eur Radiol, 27, pp.1944~1953 (2017)
  13. Talei Franzesi CR, "Diagnostic value of iterative reconstruction algorithm in low kV CT angiography(CTA)with low contrast medium volume for transcatheter aortic valve implantation(TAVI)planning : image quality and radiation dose exposure", Br J Radiol, 91, pp.20170802~ (2018)
  14. Hachulla AL, "Low iodine contrast injection for CT acquisition prior to transcatheter aortic valve replacement : aorta assessment and screening for coronary artery disease", Acad Radiol, 26, pp.e150~e160 (2019)
  15. Onoda H, "Clinical advantages of using low tube voltage in third-generation 192-slice dual-source computed tomographic angiography before transcatheter aortic valve implantation", Int Heart J, 60, pp.1091~1097 (2019)
  16. Ippolito D, "Computed tomography angiography combined with knowledge-based iterative algorithm for transcatheter aortic valve implantation planning : image quality and radiation dose exposure with low-kV and low-contrast-medium protocol", J Comput Assist Tomogr, 44, pp.13~19 (2020)
  17. Suchá D, "Effect of low contrast medium-dose CTA on device sizing and access vessel assessment for TAVR", Eur J Radiol, 124, pp.108826~ (2020)
  18. Zemedkun M, "Effectiveness of a low contrast load CT angiography protocol in octogenarians and nonagenarians being evaluated for transcatheter aortic valve replacement", Clin Imaging, 39, pp.815~819 (2015)
  19. Truong VT, "Low-volume contrast CT angiography via pulmonary artery injection for measurement of aortic annulus in patients undergoing transcatheter aortic valve replacement", J Invasive Cardiol, 29, pp.181~186 (2017)
  20. McCollough CH, "Dual-and multi-energy CT : principles, technical approaches, and clinical applications", Radiology, 276, pp.637~653 (2015)
  21. Patino M, "Material separation using dual-energy CT : current and emerging applications", Radiographics, 36, pp.1087~1105 (2016)
  22. Zopfs D, "Improved depiction of atherosclerotic carotid artery stenosis in virtual monoenergetic reconstructions of venous phase dual-layer computed tomography in comparison to polyenergetic reconstructions", Eur J Radiol, 100, pp.36~42 (2018)
  23. Vlahos I, "Dual-energy computed tomography imaging of the aorta", J Thorac Imaging, 25, pp.289~300 (2010)
  24. Cavallo AU, "Low dose contrast CT for transcatheter aortic valve replacement assessment : results from the prospective SPECTACULAR study(spectral CT assessment prior to TAVR)", J Cardiovasc Comput Tomogr, 14, pp.68~74 (2020)
  25. Mangold D, "Dual-layer spectral CTA for TAVI planning using a split-phase protocol and low-keV virtual monoenergetic images: improved image quality in comparison with single-phase conventional CTA", RoFo Fortschr Geb Rontgenstr Nuklearmed, 2021 (2021)
  26. Bittner DO, "Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation", Eur Radiol, 26, pp.4497~4504 (2016)
  27. Kok M, "Low contrast media volume in pre-TAVI CT examinations", Eur Radiol, 26, pp.2426~2435 (2016)
  28. Dankerl P, "Computer-aided evaluation of low-dose and low-contrast agent third-generation dual-source CT angiography prior to transcatheter aortic valve implantation(TAVI)", Int J CARS, 12, pp.795~802 (2017)
  29. Blanke P, "Computed tomography imaging in the context of transcatheter aortic valve implantation(TAVI)", transcatheter aortic valve replacement(TAVR) : an expert consensus document of the society of cardiovascular computed tomography, 2019, pp.12, 1~24
  30. Toprak O, "Conflicting and new risk factors for contrast induced nephropathy", J Urol, 178, pp.2277~2283 (2007)

관련 논문AI추천

Is a Low Dose Computed Tomography Angiography Protocol Feasible in Terms of Maintaining Adequate Diagnostic Image Quality for TAVR Candidates?고성민한국심초음파학회 · Journal of Cardiovascular Imaging2023 · 제31권 제2호Transcatheter Aortic Valve Replacement with Minimal Contrast Dye in Patients with Renal Insufficiency고영국, 김병극, 김중선, 심지영, 안철민, 장양수, 최동훈, 최자연, 홍그루, 홍명기, 홍성진연세대학교의과대학 · Yonsei Medical Journal2021 · 제62권 제11호Distribution of Aortic Root Calcium in Relation to Frame Expansion and Paravalvular Leakage After Transcatheter Aortic Valve Implantation (TAVI): An Observational Study Using a Patient-specific Contrast Attenuation Coefficient for Calcium Definition and Independent Core Lab Analysis of Paravalvular LeakageBen Ren, Eric Boersma, Joost Daemen, Nahid El Faquir, Nicolas M van Mieghem, Patrick Geeve, Peter P de Jaegere, Quinten Wolff, Rafi Sakhi, Ricardo P J Budde, Sander van Weenen, Zouhair Rahhab한국심초음파학회 · Journal of Cardiovascular Imaging2022 · 제30권 제4호Contrast-free (Zero-contrast) TAVR for Severe Aortic Stenosis in Patient with Chronic Kidney Disease고영국, 김다래, 홍그루, 홍명기, Chul-Min Ahn, Yeon-Jik Choi한국지질동맥경화학회 · 지질·동맥경화학회지2018 · 제7권 제1호Enhancing cardiology imaging: usability and implications of aortic annulus sizing software in transcatheter aortic valve replacement planningJah Yeon Choi한국심초음파학회 · Journal of Cardiovascular Imaging2024 · 제32권 Recent updates in transcatheter aortic valve implantation김웅, 조정환영남대학교 의과대학 · Journal of Yeungnam Medical Science2018 · 제35권 제1호

이 간행물의 다른 논문 (9건)