Objectives: The Internet of Things (IoT) and its applications are growing simultaneously. These applications need new intelligent devices along heterogeneous networking. Which makes them costly to implement indeed. Platforms and open devices designed for open-source hardware are possible solutions. This research was conducted under an IoT design, implementation, and assessment model for the remote monitoring of pulse oximetry via oxygen partial saturation (SpO2) and heart rate (HR) with low-energy consumption. Methods: This study focused on the development of SpO2 and HR measurements that will allow the monitoring and estimation in real time of the user’s state and health related to the established parameters. Measurements were acquired and recorded using a remote web server that recorded the acquired variables for further processing. The statistical analysis data allows comparison of the registered data measured with theoretical models. Results: The IoT model was developed use Bluetooth low-energy devices, which comply with low-cost and open-hardware solutions operated via ‘HTTP requests’ for data transmission and reception from a cloud server to an edge device. Network performance assessment was conducted to guarantee the availability and integrity of the acquired values and signals. The system measured SpO2 and HR variables. The most significant result was to achieve energy consumption 20% lower than that of devices in the market. Conclusions: In summary, the acquired data validation based on the IoT model had a transmission error of 0.001% which proves its applicability in healthcare.

Abstract

Objectives: The Internet of Things (IoT) and its applications are growing simultaneously. These applications need new intelligent devices along heterogeneous networking. Which makes them costly to implement indeed. Platforms and open devices designed for open-source hardware are possible solutions. This research was conducted under an IoT design, implementation, and assessment model for the remote monitoring of pulse oximetry via oxygen partial saturation (SpO2) and heart rate (HR) with low-energy consumption. Methods: This study focused on the development of SpO2 and HR measurements that will allow the monitoring and estimation in real time of the user’s state and health related to the established parameters. Measurements were acquired and recorded using a remote web server that recorded the acquired variables for further processing. The statistical analysis data allows comparison of the registered data measured with theoretical models. Results: The IoT model was developed use Bluetooth low-energy devices, which comply with low-cost and open-hardware solutions operated via ‘HTTP requests’ for data transmission and reception from a cloud server to an edge device. Network performance assessment was conducted to guarantee the availability and integrity of the acquired values and signals. The system measured SpO2 and HR variables. The most significant result was to achieve energy consumption 20% lower than that of devices in the market. Conclusions: In summary, the acquired data validation based on the IoT model had a transmission error of 0.001% which proves its applicability in healthcare.

참고문헌 (25)

  1. Son LP, "Design an IoT wrist-device for SpO2 measurement", Proceedings of 2017 International Conference on Advanced Technologies for Communications (ATC), pp.144~149 (2017)
  2. Lee I, "The Internet of Things(IoT) : applications, investments, and challenges for enterprises", Bus Horiz, 58(4), pp.431~440 (2015)
  3. Vogler M., "Efficient IoT application delivery and management in smart city environments", pp.2016
  4. Valdivieso Caraguay AL, "SDN: evolution and opportunities in the development IoT applications", Int J Distrib Sens Netw, 10(5), pp.735142~ (2014)
  5. Ma HD, "Internet of Things : objectives and scientific challenges", J Comp Sci Technol, 26(6), pp.919~924 (2011)
  6. Atzori L, "Understanding the Internet of Things : definition, potentials, and societal role of a fast evolving paradigm", Ad Hoc Netw, 56, pp.122~140 (2017)
  7. Chiang M, "Fog and IoT : an overview of research opportunities", IEEE Internet Things J, 3(6), pp.854~864 (2016)
  8. Kelly SD, "Towards the implementation of IoT for environmental condition monitoring in homes", IEEE Sens J, 13(10), pp.3846~3853 (2013)
  9. Al-Fuqaha A, "Internet of Things : a survey on enabling technologies, protocols, and applications", IEEE Com-mun Surv Tutor, 17(4), pp.2347~2376 (2015)
  10. Wang J, "Adaptive computing optimization in software-defined network-based industrial Internet of Things with fog computing", Sensors(Basel), 18(8), pp.2509~ (2018)
  11. Ibarra-Lancheros KS, "Quality of service evaluation based on network slicing for software-defined 5G systems", TecnoLogicas, 21(43), pp.27~41 (2018)
  12. Sundararaman LV, "Integration of mobile health technology in the treatment of chronic pain : a critical review", Reg Anesth Pain Med, 42(4), pp.488~498 (2017)
  13. Severinghaus JW, "Takuo Aoyagi: discovery of pulse oximetry", Anesth Analg, 105(6 Suppl), pp.S1~S4 (2007)
  14. Aarrestad S, "Diagnostic accuracy of simple tools in monitoring patients with chronic hypoventilation treated with non-invasive ventilation; a prospective cross-sectional study", Respir Med, 144, pp.30~35 (2018)
  15. Song S, "Use of bi-level pulsed frequency-division excitation for improving blood oxygen saturation precision", Measurement, 129, pp.523~529 (2018)
  16. O’Leary RJ Jr, "Buccal pulse oximeter is more accurate than finger pulse oximeter in measuring oxygen saturation", Anesth Analg, 75(4), pp.495~498 (1992)
  17. Arruza J, "Esfuerzo percibido y frecuencia cardiaca : El control de la intensidad de los esfuerzos en el entrenamiento de judo", Revista de Psicologia del Deporte, 5(2), pp.29~40 (2007)
  18. Mendonca F, "A portable wireless device based on oximetry for sleep apnea detection", Computing, 100(11), pp.1203~1219 (2018)
  19. "Medida de la Saturacion de Oxigeno por Medio Optico" (2004)[URL]
  20. Muncharaz AB, "Relationship between pulse oximetry and determination of arterial oxygen saturation. Influence of vasoactive drugs on the SattcO2-SatO2 correlation", Med Intensiva, 25(9), pp.333~339 (2001)
  21. C. Chan, "A smartphone oximeter with a fingertip probe for use during exercise training: usability, validity and reliability in individuals with chronic lung disease and healthy controls", Physiotherapy, 105(3), pp.297~306 (2019), Elsevier BV[DOI]
  22. Gong G, "Study of an oxygen supply and oxygen saturation monitoring system for radiation therapy associated with the active breathing coordinator", Sci Rep, 8(1), pp.1254~ (2018)
  23. Jones GA, "Error without trials : Safe SpO(2)threshold levels may not be derivable from SpO(2)-PaO(2)relationships", J Crit Care, 40, pp.283~284 (2017)
  24. Al Rajeh AM, "Monitoring of physiological parameters to predict exacerbations of chronic obstructive pulmonary disease(COPD) : a systematic review", J Clin Med, 5(12), pp.108~ (2016)
  25. 김정아, "The Internet of Healthy Things", Healthcare Informatics Research, 22(3), pp.250~252 (2016), 대한의료정보학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (10건)