Purpose: This dissertation is a descriptive research study analyzing the accuracy and reliability of the cardiopulmonary resuscitation (CPR) application developed in Korea. Methods: Two faculty members from the emergency medical services department and the emergency medicine department searched applications from July 1 to July 10, 2019 and selected a total of 13 applications. Twelve questions were assessed for information accuracy and three were assessed for reliability. In accordance with application types, the number and mean ± standard deviation were analyzed. The t-test was used to compare the accuracy of CPR information in accordance with information sources. Results: The results revealed the following errors: 7 cases (53.8%) identified the chest center lining from the nipple center-line as the chest pressure point; 5 cases (38.5%) did not provide information on the depth of 6 cm that should not be exceeded; and 4 cases (30.8%) did not provide advise to check respiration. When the CPR information sources were included, the information accuracy score was high; a significant difference was observed (p=.035). Conclusion: In the case of applications providing medical information regarding CPR, it is necessary to provide at least authoritarian, sources of information, and author transparency as well as continuous effort and attention.
Abstract
Purpose: This dissertation is a descriptive research study analyzing the accuracy and reliability of the cardiopulmonary resuscitation (CPR) application developed in Korea. Methods: Two faculty members from the emergency medical services department and the emergency medicine department searched applications from July 1 to July 10, 2019 and selected a total of 13 applications. Twelve questions were assessed for information accuracy and three were assessed for reliability. In accordance with application types, the number and mean ± standard deviation were analyzed. The t-test was used to compare the accuracy of CPR information in accordance with information sources. Results: The results revealed the following errors: 7 cases (53.8%) identified the chest center lining from the nipple center-line as the chest pressure point; 5 cases (38.5%) did not provide information on the depth of 6 cm that should not be exceeded; and 4 cases (30.8%) did not provide advise to check respiration. When the CPR information sources were included, the information accuracy score was high; a significant difference was observed (p=.035). Conclusion: In the case of applications providing medical information regarding CPR, it is necessary to provide at least authoritarian, sources of information, and author transparency as well as continuous effort and attention.
참고문헌 (21)
- Monica E. Kleinman, "Part 5: Adult Basic Life Support and Cardiopulmonary Resuscitation Quality", Circulation, 132(18 suppl 2), pp.S414~S435 (2015), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Internet Usage Survey for 2018, "Korea Internet & Security Agency", Korea Internet &Security Agency, ~ (2018)
- "The investigational study on health-related mobile application software and its improvement" (2015)[URL]
- Ecc Committee, "2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care", Circulation, 112(24_Suppl) (2005)[DOI]
- Rudolph W. Koster, "European Resuscitation Council Guidelines for Resuscitation 2010 Section 2. Adult basic life support and use of automated external defibrillators", Resuscitation, 81(10), pp.S1277~S1292 (2010), Elsevier BV[DOI]
- A. H. Travers, "Part 4: CPR Overview: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care", Circulation, 122(18_suppl_3), pp.S676~S684 (2010), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Robert W. Neumar, "Part 1: Executive Summary", Circulation, 132(18 suppl 2), pp.S315~S367 (2015), Ovid Technologies (Wolters Kluwer Health)[DOI]
- 류승범, "국내 유명 포털사이트의 성인 기본소생술에 대한 동영상의 적절성", 대한응급의학회지, 26(1), pp.51~61 (2015), 대한응급의학회
- 강희도, "국내 인터넷 웹 페이지에 나타난 기본심폐소생술 정보의 질 평가", 의료커뮤니케이션, 13(2), pp.125~132 (2018), 대한의료커뮤니케이션학회[DOI]
- 김현모, "최종사용자 만족도 구성요인에 대한 연구 : 어플리케이션 마켓을 중심으로", 품질경영학회지, 40(2), pp.211~218 (2012), 한국품질경영학회[DOI]
- "Health on the net code of conducts. vers. 1.6" (2006)[URL]
- Shinji Kusunoki, "Safety of the inter-nipple line hand position landmark for chest compression", Resuscitation, 80(10), pp.1175~1180 (2009), Elsevier BV[DOI]
- Ahamed H. Idris, "Relationship Between Chest Compression Rates and Outcomes From Cardiac Arrest", Circulation, 125(24), pp.3004~3012 (2012), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Benjamin S. Abella, "Chest Compression Rates During Cardiopulmonary Resuscitation Are Suboptimal", Circulation, 111(4), pp.428~434 (2005), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Ryu SW, "Management practices in the quality of health information on the Internet", Health and welfare forum, 86, pp.68~82 (2003)
- 강보라, "심폐소생술(CPR) 및 자동제세동기(AED)에 대한 웹사이트 내용성 분석", 보건의료산업학회지, 7(3), pp.29~44 (2013), 보건의료산업학회
- Karthik Murugiah, "YouTube as a source of information on cardiopulmonary resuscitation", Resuscitation, 82(3), pp.332~334 (2011), Elsevier BV[DOI]
- Ian G. Stiell, "What Is the Optimal Chest Compression Depth During Out-of-Hospital Cardiac Arrest Resuscitation of Adult Patients?", Circulation, 130(22), pp.1962~1970 (2014), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Tyler Vadeboncoeur, "Chest compression depth and survival in out-of-hospital cardiac arrest", Resuscitation, 85(2), pp.182~188 (2014), Elsevier BV[DOI]
- Ian G. Stiell, "What is the role of chest compression depth during out-of-hospital cardiac arrest resuscitation?*", Critical Care Medicine, 40(4), pp.1192~1198 (2012), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Heidi Hellevuo, "Deeper chest compression – More complications for cardiac arrest patients?", Resuscitation, 84(6), pp.760~765 (2013), Elsevier BV[DOI]