Current Status and Research into Overcoming Limitations of Capsule Endoscopy
1
조회
0
다운로드
6
인용
0
참고문헌
키워드
초록
Endoscopic investigation has a critical role in the diagnosis and treatment of gastrointestinal (GI) diseases. Since 2001, capsule endoscopy (CE) has been available for small-bowel exploration and is under continuous development. During the past decade, CE has achieved impressive improvements in areas such as miniaturization, resolution, and battery life. As a result, CE is currently a first-line tool for the investigation of the small bowel in obscure gastrointestinal bleeding and is a useful alternative to wired enteroscopy. Nevertheless, CE still has several limitations, such as incomplete examination and limited diagnostic and therapeutic capabilities. To resolve these problems, many groups have suggested several models (e.g., controlled CO2 insufflation system, magnetic navigation system, mobile robotic platform, tagging and biopsy equipment, and targeted drug-delivery system), which are in development. In the near future, new technological advances will improve the capabilities of CE and broaden its spectrum of applications not only for the small bowel but also for the colon, stomach, and esophagus. The purpose of this review is to introduce the current status of CE and to review the ongoing development of solutions to address its limitations.
Abstract
Endoscopic investigation has a critical role in the diagnosis and treatment of gastrointestinal (GI) diseases. Since 2001, capsule endoscopy (CE) has been available for small-bowel exploration and is under continuous development. During the past decade, CE has achieved impressive improvements in areas such as miniaturization, resolution, and battery life. As a result, CE is currently a first-line tool for the investigation of the small bowel in obscure gastrointestinal bleeding and is a useful alternative to wired enteroscopy. Nevertheless, CE still has several limitations, such as incomplete examination and limited diagnostic and therapeutic capabilities. To resolve these problems, many groups have suggested several models (e.g., controlled CO2 insufflation system, magnetic navigation system, mobile robotic platform, tagging and biopsy equipment, and targeted drug-delivery system), which are in development. In the near future, new technological advances will improve the capabilities of CE and broaden its spectrum of applications not only for the small bowel but also for the colon, stomach, and esophagus. The purpose of this review is to introduce the current status of CE and to review the ongoing development of solutions to address its limitations.
참고문헌 (49)
- Rondonotti E, "Small bowel capsule endoscopy in clinical practice: a multicenter 7-year survey", Eur J Gastroenterol Hepatol, 22, pp.1380~1386 (2010)
- Koulaouzidis A, "Small-bowel capsule endoscopy: a ten-point contemporary review", World J Gastroenterol, 19, pp.3726~3746 (2013)
- Fisher LR, "New vision in video capsule endoscopy: current status and future directions", Nat Rev Gastroenterol Hepatol, 9, pp.392~405 (2012)
- Eliakim R, "Video capsule endoscopy of the small bowel", Curr Opin Gastroenterol, 29, pp.133~139 (2013)
- Ladas SD, "European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases", Endoscopy, 42, pp.220~227 (2010)
- Bouchard S, "Video capsule endoscopy:perspectives of a revolutionary technique", World J Gastroenterol, 20, pp.17330~17344 (2014)
- Van de Bruaene C, "Small bowel capsule endoscopy: Where are we after almost 15 years of use?", World J Gastrointest Endosc, 7, pp.13~36 (2015)
- Koulaouzidis A, "Fecal calprotectin: a selection tool for small bowel capsule endoscopy in suspected IBD with prior negative bi-directional endoscopy", Scand J Gastroenterol, 46, pp.561~566 (2011)
- Winawer SJ, "Prevention of colorectal cancer by colonoscopic polypectomy. The National Polyp Study Workgroup", N Engl J Med, 329, pp.1977~1981 (1993)
- Van Gossum A, "Capsule endoscopy versus colonoscopy for the detection of polyps and cancer", N Engl J Med, 361, pp.264~270 (2009)
- Spada C, "Second-generation colon capsule endoscopy compared with colonoscopy", Gastrointest Endosc, 74, pp.581~589.e1 (2011)
- Eliakim R, "Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy", Endoscopy, 41, pp.1026~1031 (2009)
- Gupta T, "Evaluation of Fujinon intelligent chromo endoscopy-assisted capsule endoscopy in patients with obscure gastroenterology bleeding", World J Gastroenterol, 17, pp.4590~4595 (2011)
- Matsumura T, "Efficacy of computed image modification of capsule endoscopy in patients with obscure gastrointestinal bleeding", World J Gastrointest Endosc, 4, pp.421~428 (2012)
- Krystallis C, "Chromoendoscopy in small bowel capsule endoscopy: blue mode or Fuji Intelligent Colour Enhancement?", Dig Liver Dis, 43, pp.953~957 (2011)
- Imagawa H, "Improved detectability of small-bowel lesions via capsule endoscopy with computed virtual chromoendoscopy:a pilot study", Scand J Gastroenterol, 46, pp.1133~1137 (2011)
- Demosthenous P, "Towards a fluoroscopic cancer screening capsule for the small intestine", Conf Proc IEEE Eng Med Biol Soc, 2014, pp.3122~3125 (2014)
- Zhang R, "Shape-from-shading: a survey", IEEE Trans Pattern Anal Mach Intell, 21, pp.690~706 (1999)
- Koulaouzidis A, "Three-dimensional representation software as image enhancement tool in small-bowel capsule endoscopy: a feasibility study", Dig Liver Dis, 45, pp.909~914 (2013)
- Rondonotti E, "Utility of 3-dimensional image reconstruction in the diagnosis of small-bowel masses in capsule endoscopy(with video)", Gastrointest Endosc, 80, pp.642~651 (2014)
- Pasricha T, "Controlled colonic insufflation by a remotely triggered capsule for improved mucosal visualization", Endoscopy, 46, pp.614~618 (2014)
- Gorlewicz JL, "Wireless insufflation of the gastrointestinal tract", IEEE Trans Biomed Eng, 60, pp.1225~1233 (2013)
- Shiotani A, "Use of an external real-time image viewer coupled with prespecified actions enhanced the complete examinations for capsule endoscopy", J Gastroenterol Hepatol, 26, pp.1270~1274 (2011)
- Marya N, "Computerized 3-dimensional localization of a video capsule in the abdominal cavity:validation by digital radiography", Gastrointest Endosc, 79, pp.669~674 (2014)
- Liao Z, "Completion rate and diagnostic yield of small-bowel capsule endoscopy: 1 vs. 2 frames per second", Endoscopy, 42, pp.360~364 (2010)
- Gao Y, "Low-power ultrawideband wireless telemetry transceiver for medical sensor applications", IEEE Trans Biomed Eng, 58, pp.768~772 (2011)
- Xin W, "Study of a wireless power transmission system for an active capsule endoscope", Int J Med Robot, 6, pp.113~122 (2010)
- Lucarini G, "A new concept for magnetic capsule colonoscopy based on an electromagnetic system", Int J Adv Robot Syst, 12, pp.25~ (2015)
- Quirini M, "Feasibility proof of a legged locomotion capsule for the GI tract", Gastrointest Endosc, 67, pp.1153~1158 (2008)
- Kim HM, "Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment(with videos)", Gastrointest Endosc, 72, pp.381~387 (2010)
- Tortora G, "Propeller-based wireless device for active capsular endoscopy in the gastric district", Minim Invasive Ther Allied Technol, 18, pp.280~290 (2009)
- Carpi F, "Stereotaxis Niobe magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy", Expert Rev Med Devices, 6, pp.487~498 (2009)
- Valdastri P, "A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications", Endoscopy, 42, pp.481~486 (2010)
- Rey JF, "Feasibility of stomach exploration with a guided capsule endoscope", Endoscopy, 42, pp.541~545 (2010)
- Menciassi A, "Locomotion of a legged capsule in the gastrointestinal tract : theoretical study and preliminary technological results", Conf Proc IEEE Eng Med Biol Soc, 4, pp.2767~2770 (2004)
- Quirini M, "An approach to capsular endoscopy with active motion", Conf Proc IEEE Eng Med Biol Soc, 2007, pp.2827~2830 (2007)
- Kim HM, "Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos).", Gastrointest Endosc, 72, pp.381~387 (2010)
- Yang S, "Autonomous locomotion of capsule endoscope in gastrointestinal tract", Conf Proc IEEE Eng Med Biol Soc, 2011, pp.6659~6663 (2011)
- Tortora G, "Propeller-based wireless device for active capsular endoscopy in the gastric district", Minim Invasive Ther Allied Technol, 18, pp.280~290 (2009)
- Gao M, "Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscope", IEEE Trans Biomed Eng, 57, pp.2891~2902 (2010)
- Simi M, "Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration", Mechatron IEEE, 2010, pp.15, 170~180
- Chandrappan J, "Tagging module for lesion localization in capsule endoscopy", Conf Proc IEEE Eng Med Biol Soc, 2010, pp.1890~1893 (2010)
- Kong KC, "A rotational micro biopsy device for the capsule endoscope", Proceedings of the Intelligent Robots and Systems, 2005 (IROS 2005) 2005 IEEE, 2005, 1839~1843[DOI]
- Park S, "A novel microactuator for microbiopsy in capsular endoscopes", J Micromech Microeng, 18, pp.025032~ (2008)
- Valdastri P, "Wireless therapeutic endoscopic capsule: in vivo experiment", Endoscopy, 40, pp.979~982 (2008)
- Wilding II, "Development of a new engineering-based capsule for human drug absorption studies", Pharm Sci Technolo Today, 3, pp.385~392 (2000)
- Woods SP, "Wireless capsule endoscope for targeted drug delivery: mechanics and design considerations", IEEE Trans Biomed Eng, 60, pp.945~953 (2013)
- Schostek S, "European research on wireless endoscopy: the VECTOR project", Stud Health Technol Inform, 189, pp.193~199 (2013)
- Swain P, "The future of wireless capsule endoscopy", World J Gastroenterol, 14, pp.4142~4145 (2008)
