Effect of Charcoal Filter on the Emergence from Sevoflurane Anesthesia in a Semi-Closed Rebreathing Circuit
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Purpose: A charcoal filter attached within the anesthetic circuit has been shown to efficiently adsorb halothane or isoflurane, thus hastening anesthetic recovery in low or minimal flow system. This study was intended to demonstrate whether the charcoal filter enhances the recovery time from sevoflurane anesthesia using a semi-closed circuit system. Materials and Methods: Thirty healthy patients scheduled for elective surgery under sevoflurane anesthesia were randomly assigned to the charcoal filter or control group. Upon completion of surgery, the end-tidal concentration of sevoflurane was maintained at 2.0 vol%. A charcoal filter was attached to the expiratory limb of the breathing circuit of charcoal filter group subjects. After sevoflurane was discontinued, ventilation was controlled with the same minute volume as the intra-operative period at a fresh gas flow rate of 5 L·min-1 with 100% O2. The elimination kinetics of sevoflurane from end-tidal concentration,Bispectral index and times of eye opening and extubation were obtained. Results: The exponential time constant (τ) of alveolar sevoflurane concentration in the charcoal filter group was significantly shorter than that in the control group (1.7±0.5 vs. 2.5±1.1 min, p=0.008). The charcoal filter hastened rapid eye opening (11.1±3.8 vs. 14.8±3.0 min, p=0.007) and extubation (11.9±3.9 vs. 15.3±3.2 min, p=0.014), compared to the control group. Conclusion: A charcoal filter enhances the recovery from sevoflurane anesthesia with a semi-closed rebreathing circuit.
Abstract
Purpose: A charcoal filter attached within the anesthetic circuit has been shown to efficiently adsorb halothane or isoflurane, thus hastening anesthetic recovery in low or minimal flow system. This study was intended to demonstrate whether the charcoal filter enhances the recovery time from sevoflurane anesthesia using a semi-closed circuit system. Materials and Methods: Thirty healthy patients scheduled for elective surgery under sevoflurane anesthesia were randomly assigned to the charcoal filter or control group. Upon completion of surgery, the end-tidal concentration of sevoflurane was maintained at 2.0 vol%. A charcoal filter was attached to the expiratory limb of the breathing circuit of charcoal filter group subjects. After sevoflurane was discontinued, ventilation was controlled with the same minute volume as the intra-operative period at a fresh gas flow rate of 5 L·min-1 with 100% O2. The elimination kinetics of sevoflurane from end-tidal concentration,Bispectral index and times of eye opening and extubation were obtained. Results: The exponential time constant (τ) of alveolar sevoflurane concentration in the charcoal filter group was significantly shorter than that in the control group (1.7±0.5 vs. 2.5±1.1 min, p=0.008). The charcoal filter hastened rapid eye opening (11.1±3.8 vs. 14.8±3.0 min, p=0.007) and extubation (11.9±3.9 vs. 15.3±3.2 min, p=0.014), compared to the control group. Conclusion: A charcoal filter enhances the recovery from sevoflurane anesthesia with a semi-closed rebreathing circuit.
참고문헌 (19)
- Neuvonen PJ, "Oral activated charcoal in the treatment of intoxications. Role of single and repeated doses", Med Toxicol Adverse Drug Exp, 3, pp.33~58 (1988)
- Alexander KD, "Adsorption of halothane from a paediatric T-piece circuit by activated charcoal", Anaesth Intensive Care, 5, pp.218~222 (1977)
- Enderby DH, "Investigations of some aspects of atmospheric pollution by anaesthetic gases. II: Aspects of ad sorption and emission of halothane by different charcoals", Br J Anaesth, 49, pp.567~573 (1977)
- Murrin KR, "Adsorption of halothane by activated charcoal. Further studies", Anaesthesia, 29, pp.458~461 (1974)
- Romano E, "Low-flow anaesthesia systems, charcoal and isoflurane kinetics", Anaesthesia, 47, pp.1098~1099 (1992)
- Højkjaer Larsen V, "Removal of halogenated anaesthetics from a closed circle system with a charcoal filter", Acta Anaesthesiol Scand, 33, pp.374~378 (1989)
- Romano E, "Adsorption of volatile anesthetics on activated charcoal. Efficiency of an experimental filter during low-flow circuit ventilation", Minerva Anestesiol, 61, pp.437~440 (1995)
- Maggs FA, "Adsorption of anaesthetic vapours on charcoal beds", Anaesthesia, 31, pp.30~40 (1976)
- Campbell C, "Clinical comparison of sevoflurane and isoflurane when administered with nitrous oxide for surgical procedures of intermediate duration", Can J Anaesth, 42, pp.884~890 (1995)
- Castagnini HE, "Sevoflurane for interventional neuroradiology procedures is associated with more rapid early recovery than propofol", Can J Anaesth, 51, pp.486~491 (2004)
- Eger EI 2nd, "The effect of anesthetic duration on kinetic and recovery characteristics of desflurane versus sevoflurane, and on the kinetic characteristics of compound A, in volunteers", Anesth Analg, 86, pp.414~421 (1998)
- Ernst EA, "Use of charcoal to rapidly decrease depth of anesthesia while maintaining a closed circuit", Anesthesiology, 57, pp.343~ (1982)
- Sakata DJ, "Rapid recovery from sevoflurane and desflurane with hypercapnia and hyperventilation", Anesth Analg, 105, pp.79~82 (2007)
- Grottke O, "Intraoperative wake-up test and postoperative emergence in patients undergoing spinal surgery: a comparison of intravenous and inhaled anesthetic techniques using short-acting anesthetics", Anesth Analg, 99, pp.1521~1527 (2004)
- Greene ER Jr, "Malignant hyperthermia: removal of volatile anesthetic agents from the breathing circuit using activated charcoal", Anesthesiology, 65, pp.240~241 (1986)
- Jantzen JP, "An activated charcoal filter for eliminating volatile anesthetics. A contribution to the management of malignant hyperthermia", Anaesthesist, 38, pp.639~641 (1989)
- Hawkins TJ, "Atmospheric pollution in operating theatres. A review and a report on the use of reuseable activated charcoal canisters", Anaesthesia, 28, pp.490~500 (1973)
- Yoganathan S, "Determination of contamination of a chemical warfare-proof operating theatre with volatile anaesthetic agents and assessment of anaesthetic gas scavenging systems", Br J Anaesth, 67, pp.614~617 (1991)
- Højkjaer Larsen V, "Removal of halogenated anaesthetics from a closed circle system with a charcoal filter", Acta Anaesthesiol Scand, 33, pp.374~378 (1989)
