Purpose: We devised an intraoperatively identifiable mechanical axis (IIMA) as a reference of alignment in total knee arthroplasty (TKA). Materials and Methods: Between February 2010 and January 2011, primary TKAs were consecutively performed on 672 patients (1007 knees) using an IIMA as a reference in the coronal plane. Results: The alignment of the lower extremity improved from a mean of 11.4±6.7° (-10.3-34.4°) of varus preop. to 0.7±3.5° (-5.2-8.6°) immediately after surgery. Mean alignment of the femoral component in the coronal plane was 89.3±2.3° (83.4-97.2°) postop. and mean alignment of the tibial component was 90.4±2.2° (85.1-94.2°) postop. Conclusion: This study showed that IIMA could be of considerable value as a new guider of alignment that is easily accessible and highly effective during total knee arthroplasty.

Abstract

Purpose: We devised an intraoperatively identifiable mechanical axis (IIMA) as a reference of alignment in total knee arthroplasty (TKA). Materials and Methods: Between February 2010 and January 2011, primary TKAs were consecutively performed on 672 patients (1007 knees) using an IIMA as a reference in the coronal plane. Results: The alignment of the lower extremity improved from a mean of 11.4±6.7° (-10.3-34.4°) of varus preop. to 0.7±3.5° (-5.2-8.6°) immediately after surgery. Mean alignment of the femoral component in the coronal plane was 89.3±2.3° (83.4-97.2°) postop. and mean alignment of the tibial component was 90.4±2.2° (85.1-94.2°) postop. Conclusion: This study showed that IIMA could be of considerable value as a new guider of alignment that is easily accessible and highly effective during total knee arthroplasty.

참고문헌 (26)

  1. Baldini A, "Less invasive TKA: extramedullary femoral reference without navigation", Clin Orthop Relat Res, 466, pp.2694~2700 (2008)
  2. Bardakos N, "Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study", J Arthroplasty, 22(6), pp.85~89 (2007)
  3. Berend M, "Consequences of Malalignment in Total Knee Arthroplasty: Few if Any-Opposes", Semin Arthroplast, 21, pp.99~101 (2010)
  4. Choong PF, "Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty", J Arthroplasty, 24, pp.560~569 (2009)
  5. Cooke TD, "Definition of axial alignment of the lower extremity", J Bone Joint Surg Am, 84-A, pp.146~147 (2002)
  6. Werner FW, "The effect of valgus", varus malalignment on load distribution in total knee replacements, 2005, pp.38, 349~355
  7. Ishida K, "Mid-term outcomes of computer-assisted total knee arthroplasty", Knee Surg Sports Traumatol Arthrosc, 19, pp.1107~1112 (2011)
  8. Sikorski JM, "Alignment in total knee replacement", J Bone Joint Surg Br, 90, pp.1121~1127 (2008)
  9. Huang TW, "Total knee replacement in patients with significant femoral bowing in the coronal plane: a comparison of conventional and computer-assisted surgery in an Asian population", J Bone Joint Surg Br, 93, pp.345~350 (2011)
  10. Huang TW, "Total knee arthroplasty with use of computer-assisted navigation compared with conventional guiding systems in the same patient: radiographic results in Asian patients", J Bone Joint Surg Am, 93, pp.1197~1202 (2011)
  11. Jeffery RS, "Coronal alignment after total knee replacement", J Bone Joint Surg Br, 73, pp.709~714 (1991)
  12. Mullaji A, "Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults", Skeletal Radiol, 39, pp.363~368 (2010)
  13. Mullaji AB, "A comparison of coronal plane axial femoral relationships in Asian patients with varus osteoarthritic knees and healthy knees", J Arthroplasty, 24, pp.861~867 (2009)
  14. Nagamine R, "Distal femoral cut perpendicular to the mechanical axis may induce varus instability in flexion in medial osteoarthritic knees with varus deformity in total knee arthroplasty: a pitfall of the navigation system", J Orthop Sci, 9, pp.555~559 (2004)
  15. Parratte S, "Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements", J Bone Joint Surg Am, 92, pp.2143~2149 (2010)
  16. Lee DH, "Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty", Int Orthop, 32, pp.223~227 (2008)
  17. Seo JG, "Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis", Knee Surg Sports Traumatol Arthrosc, 20, pp.538~545 (2012)
  18. Seo JG, "How precise is the identification of the center of the femoral head during total knee arthroplasty?", Acta Orthop, 83, pp.53~58 (2012)
  19. Chin PL, "Randomized controlled trial comparing the radiologic outcomes of conventional and minimally invasive techniques for total knee arthroplasty", J Arthroplasty, 22, pp.800~806 (2007)
  20. Rolston L, "Assessment of knee alignment after bicompartmental knee arthroplasty", J Arthroplasty, 24, pp.1111~1114 (2009)
  21. Mihalko WM, "Differences between extramedullary, intramedullary, and computer-aided surgery tibial alignment techniques for total knee arthroplasty", J Knee Surg, 19, pp.33~36 (2006)
  22. Catani F, "Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty", J Bone Joint Surg Am, 90, pp.765~771 (2008)
  23. Catani F, "Navigation-assisted total knee arthroplasty in knees with osteoarthritis due to extra-articular deformity", Knee Surg Sports Traumatol Arthrosc, 20, pp.546~551 (2012)
  24. Zhang GQ, "Comparison between computer-assisted-navigation and conventional total knee arthroplasties in patients undergoing simultaneous bilateral procedures: a randomized clinical trial", J Bone Joint Surg Am, 93, pp.1190~1196 (2011)
  25. Sawant MR, "A clinical method for locating the femoral head centre during total knee arthroplasty", Knee, 11, pp.209~212 (2004)
  26. Harvie P, "Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems", J Arthroplasty, 26, pp.1285~1290 (2011)

관련 논문AI추천

Clinical Outcome of IM-Guided Total Knee Arthroplasty with Inappropriate Femoral Resection in Coronal Plane문영완, 서재곤, 이근호, 장성원, 한정훈대한슬관절학회 · Knee Surgery and Related Research2013 · 제25권 제1호The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty김광균, 이도경, Jiyoon Eom, Jungsung Kim, Sohui Lim대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제1호Extramedullary Tibial Bone Cutting Using Medial Cortical Line in Total Knee Arthroplasty박상훈, 오현철, 유주형, 이윤재, 정세한, 한창동대한슬관절학회 · Knee Surgery and Related Research2017 · 제29권 제3호Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs박용범, 이한준, Jung­Won Lim, Min­Ku Song, Seong Hwan Kim대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제4호The Position of Proximal Reference Point of Tibia Plateau for Correct Tibial Osteotomy in Total Knee Replacement: Prospective Randomized and 6 Years Follow-up StudyKye Young Han, Woo Young Chae대한슬관절학회 · Knee Surgery and Related Research2011 · 제23권 제4호Effects of Femoral Lateral Bowing on Coronal Alignment and Component Position after Total Knee Arthroplasty: A Comparison of Conventional and Navigation­-Assisted Surgery이창락, Chang-Wan Kim대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제1호

이 간행물의 다른 논문 (24건)