Purpose: Thyroid ultrasonography (US) is a useful diagnostic tool in the evaluation of diffuse thyroid disease (DTD), whereas shearwave elastography is a dynamic technique that can provide information about tissue hardness by using acoustic shearwaves remotely induced by a focused ultrasonic beam. This study aims at investigating the role of conventional US and shearwave elastography in the diagnosis of asymptomatic patients with DTD. Materials and Methods: Fifty-seven patients who underwent both conventional US and shearwave elastography were included in this study. Interobserver variability of the three radiologists in assessment of underlying thyroid echogenicity on conventional US was analyzed. Diagnostic performances for diagnosing DTD on conventional US and shearwave elastography were calculated and compared. Results: Fair agreement was observed in the identification of DTD with conventional US (kappa value=0.27). The area under the receiver operating characteristic curve (Az) were 0.52-0.585 on conventional US by three radiologists. The Az values when using the mean and maximum elasticity values as a diagnostic criteria for DTD were 0.619 and 0.59 on shearwave elastography. Patients with DTD showed higher mean [24.1±10 kilo-Pascals (kPa)] and maximum (36.4±13.3 kPa) elasticity values on shearwave elastography when compared to the normal group (23.4±10.8 kPa and 33.7±12.4 kPa, respectively), although without statistical significance (p=0.802 and p=0.452, respectively). Conclusion:Conventional US did not show reliable interobserver agreement in the diagnosis of DTD. Although not statistically significant, shearwave elastography may provide additional information in the diagnosis of DTD. Therefore, larger prospective studies are needed to define the values of shearwave elastography for diagnosing DTD.

Abstract

Purpose: Thyroid ultrasonography (US) is a useful diagnostic tool in the evaluation of diffuse thyroid disease (DTD), whereas shearwave elastography is a dynamic technique that can provide information about tissue hardness by using acoustic shearwaves remotely induced by a focused ultrasonic beam. This study aims at investigating the role of conventional US and shearwave elastography in the diagnosis of asymptomatic patients with DTD. Materials and Methods: Fifty-seven patients who underwent both conventional US and shearwave elastography were included in this study. Interobserver variability of the three radiologists in assessment of underlying thyroid echogenicity on conventional US was analyzed. Diagnostic performances for diagnosing DTD on conventional US and shearwave elastography were calculated and compared. Results: Fair agreement was observed in the identification of DTD with conventional US (kappa value=0.27). The area under the receiver operating characteristic curve (Az) were 0.52-0.585 on conventional US by three radiologists. The Az values when using the mean and maximum elasticity values as a diagnostic criteria for DTD were 0.619 and 0.59 on shearwave elastography. Patients with DTD showed higher mean [24.1±10 kilo-Pascals (kPa)] and maximum (36.4±13.3 kPa) elasticity values on shearwave elastography when compared to the normal group (23.4±10.8 kPa and 33.7±12.4 kPa, respectively), although without statistical significance (p=0.802 and p=0.452, respectively). Conclusion:Conventional US did not show reliable interobserver agreement in the diagnosis of DTD. Although not statistically significant, shearwave elastography may provide additional information in the diagnosis of DTD. Therefore, larger prospective studies are needed to define the values of shearwave elastography for diagnosing DTD.

참고문헌 (31)

  1. Kim EK, "New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid", AMERICAN JOURNAL OF ROENTGENOLOGY, 178, pp.687~691 (2002), AMER ROENTGEN RAY SOC
  2. 김성준, "Ultrasound-Guided Fine-Needle Aspiration Biopsy in Nonpalpable Thyroid Nodules: Is It Useful in Infracentimetric Nodules?", Yonsei Medical Journal, 44(4), pp.635~640 (2003), 연세대학교의과대학
  3. 문원진, "Ultrasonography and the Ultrasound-Based Management of Thyroid Nodules: Consensus Statement and Recommendations", Korean Journal of Radiology, 12(1), pp.1~14 (2011), 대한영상의학회
  4. Pedersen OM, "The value of ultrasonography in predicting autoimmune thyroid disease", Thyroid, 10, pp.251~259 (2000)
  5. Shin DY, "Role of ultrasonography in outcome prediction in subclinical hypothyroid patients treated with levothyroxine", Endocrine Journal, 57(1), pp.15~22 (2010), JAPAN ENDOCRINE SOC
  6. Yeh HC, "Micronodulation: ultrasonographic sign of Hashimoto thyroiditis", J Ultrasound Med, 15, pp.813~819 (1996)
  7. Kim DW, "Sonographic Differentiation of Asymptomatic Diffuse Thyroid Disease from Normal Thyroid: A Prospective Study", AMERICAN JOURNAL OF NEURORADIOLOGY, 31, pp.1956~1960 (2010), ASNR
  8. 손유미, "Mixed Echoic Thyroid Nodules on Ultrasound: Approach to Management", Yonsei Medical Journal, 53(4), pp.812~819 (2012), 연세대학교의과대학[DOI]
  9. Mi-Jung Lee, "Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings", Yonsei Medical Journal, 52(5), pp.838~844 (2011), 연세대학교의과대학
  10. Marcocci C, "Thyroid ultrasonography helps to identify patients with diffuse lymphocytic thyroiditis who are prone to develop hypothyroidism", J Clin Endocrinol Metab, 72, pp.209~213 (1991)
  11. Hayashi N, "Sonography of Hashimoto’s thyroiditis", J Clin Ultrasound, 14, pp.123~126 (1986)
  12. Nys P, "Etiologic discussion and clinical relevance of thyroid ultrasonography in subclinical hypothyroidism. A retrospective study in 1845 patients", Ann Endocrinol (Paris), 70, pp.59~63 (2009)
  13. Rosário PW, "Natural history of mild subclinical hypothyroidism: prognostic value of ultrasound", Thyroid, 19, pp.9~12 (2009)
  14. Asteria C, "US-elastography in the differential diagnosis of benign and malignant thyroid nodules", Thyroid, 18, pp.523~531 (2008)
  15. Rago T, "Elastography: new developments in ultrasound for predicting malignancy in thyroid nodules", J Clin Endocrinol Metab, 92, pp.2917~2922 (2007)
  16. Sebag F, "Shear wave elastography: a new ultrasound imaging mode for the differential diagnosis of benign and malignant thyroid nodules", J Clin Endocrinol Metab, 95, pp.5281~5288 (2010)
  17. Ophir J, "Elastography: ultrasonic estimation and imaging of the elastic properties of tissues", Proc Inst Mech Eng H, 213, pp.203~233 (1999)
  18. Choi JS, "Staging of Papillary Thyroid Carcinoma with Ultrasonography: Performance in a Large Series", ANNALS OF SURGICAL ONCOLOGY, 18(13), pp.3572~3578 (2011), Lippincott Williams & Wilkins Ltd.
  19. Tessler FN, "Thyroid sonography: current applications and future directions", AJR Am J Roentgenol, 173, pp.437~443 (1999)
  20. Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
  21. Youden WJ, "Index for rating diagnostic tests", Cancer, 3, pp.32~35 (1950)
  22. 김성헌, "Observer Variability and the Performance between Faculties and Residents: US Criteria for Benign and Malignant Thyroid Nodules", Korean Journal of Radiology, 11(2), pp.149~155 (2010), 대한영상의학회
  23. Park CS, "Observer variability in the sonographic evaluation of thyroid nodules", J Clin Ultrasound, 38, pp.287~293 (2010)
  24. Choi SH, "Interobserver and Intraobserver Variations in Ultrasound Assessment of Thyroid Nodules", THYROID, 20, pp.167~172 (2010), MARY ANN LIEBERT INC
  25. Park SH, "Interobserver Agreement in Assessing the Sonographic and Elastographic Features of Malignant Thyroid Nodules", AMERICAN JOURNAL OF ROENTGENOLOGY, 193(5), pp.416~423 (2009), AMER ROENTGEN RAY SOC
  26. Sporea I, "Thyroid stiffness assessment by acoustic radiation force impulse elastography (ARFI)", Ultraschall Med, 32, pp.281~285 (2011)
  27. LiVolsi VA, "The pathology of autoimmune thyroid disease: a review", Thyroid, 4, pp.333~339 (1994)
  28. Lyshchik A, "Thyroid gland tumor diagnosis at US elastography", Radiology, 237, pp.202~211 (2005)
  29. Sarvazyan AP, "Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics", Ultrasound Med Biol, 24, pp.1419~1435 (1998)
  30. Tanter M, "Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging", Ultrasound Med Biol, 34, pp.1373~1386 (2008)
  31. Sporea I, "Comparative study concerning the value of acoustic radiation force impulse elastography (ARFI) in comparison with transient elastography (TE) for the assessment of liver fibrosis in patients with chronic hepatitis B and C", Ultrasound Med Biol, 38, pp.1310~1316 (2012)

관련 논문AI추천

Ultrasonographic Evaluation of Diffuse Thyroid Disease: a Study Comparing Grayscale US and Texture Analysis of Real-Time Elastography (RTE) and Grayscale US곽진영, 김은경, 문희정, 윤정현, 이은정, 이혜선대한갑상선학회 · International Journal of Thyroidology2017 · 제10권 제1호Utility of shear wave elastography to detect papillary thyroid carcinoma in thyroid nodules: efficacy of the standard deviation elasticity곽미경, 김혜정, 박형규, 변동원, 서교일, 유명희, 진소영, 최인호대한내과학회 · The Korean Journal of Internal Medicine2019 · 제34권 제4호Diagnostic Performance of a Combination of Shear Wave Elastography and B-Mode Ultrasonography in Differentiating Benign From Malignant Thyroid Nodules김의종, 박원서, 손유미, 윤성종, 은영규, 서미리내, Eung Koo Yeon대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2020 · 제13권 제2호정량적 갑상선 조직 탄성도 분석을 통한 전단파 탄성초음파의 갑상선암 진단 유용성에 관한 연구 연세대학교곽진영, 김은경대한갑상선학회 · International Journal of Thyroidology2011 · 제4권 제2호갑상선결절에서 추가 횡파 탄성 초음파검사의진단정확성: 체계적 문헌고찰과 메타분석강봉주, 고려진, 김석현, 박선영, 송지양, 이경민, 이민진, 전미혜대한갑상선학회 · International Journal of Thyroidology2018 · 제11권 제1호갑상선 탄성 초음파 검사 시 칼라 오버레이 패턴의 유용성박지연, 조평곤대한방사선과학회 · Journal of Radiological Science and Technology2022 · 제45권 제4호

이 간행물의 다른 논문 (26건)