Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound(VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent(DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VHIVUSand follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core(NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percentmalapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9±19.0, 7.9±9.6, 63.8±33.8, and 16.5±12.4 mm3,respectively. At 6.3±3.1 months post-intervention, percent malapposed and uncovered struts were 0.8±2.5% and 15.3±16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts(r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associatedwith percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independentpredictor of late stent malapposition on multivariate analysis (β=1.12, p=0.002). There were no significant correlations betweenpre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DESimplantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.

Abstract

Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound(VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent(DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VHIVUSand follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core(NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percentmalapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9±19.0, 7.9±9.6, 63.8±33.8, and 16.5±12.4 mm3,respectively. At 6.3±3.1 months post-intervention, percent malapposed and uncovered struts were 0.8±2.5% and 15.3±16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts(r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associatedwith percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independentpredictor of late stent malapposition on multivariate analysis (β=1.12, p=0.002). There were no significant correlations betweenpre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DESimplantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.

참고문헌 (22)

  1. Cook S, "Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation", Circulation, 115, pp.2426~2434 (2007)
  2. Siqueira DA, "Late incomplete apposition after drug-eluting stent implantation:incidence and potential for adverse clinical outcomes", Eur Heart J, 28, pp.1304~1309 (2007)
  3. Hassan AK, "Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis", Eur Heart J, 31, pp.1172~1180 (2010)
  4. Guagliumi G, "Examination of the in vivo mechanisms of late drug-eluting stent thrombosis: findings from optical coherence tomography and intravascular ultrasound imaging", JACC Cardiovasc Interv, 5, pp.12~20 (2012)
  5. Won H, "Optical coherence tomography derived cut-off value of uncovered stent struts to predict adverse clinical outcomes after drug-eluting stent implantation", Int J Cardiovasc Imaging, 29, pp.1255~1263 (2013)
  6. Im E, "Incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drugeluting stent implantation", Circ Cardiovasc Interv, 7, pp.88~96 (2014)
  7. Kim BK, "Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation", Int J Cardiovasc Imaging, 28, pp.705~714 (2012)
  8. Guo N, "Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myocardial infarction: an intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial", Circulation, 122, pp.1077~1084 (2010)
  9. Gutiérrez-Chico JL, "Vascular tissue reaction to acute malapposition in human coronary arteries: sequential assessment with optical coherence tomography", Circ Cardiovasc Interv, 5, pp.20~29 (2012)
  10. Ozaki Y, "The fate of incomplete stent apposition with drug-eluting stents:an optical coherence tomography-based natural history study", Eur Heart J, 31, pp.1470~1476 (2010)
  11. Mintz GS, "American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents", J Am Coll Cardiol, 37, pp.1478~1492 (2001)
  12. Nair A, "Coronary plaque classification with intravascular ultrasound radiofrequency data analysis", Circulation, 106, pp.2200~2206 (2002)
  13. Nasu K, "Accuracy of in vivo coronary plaque morphology assessment:a validation study of in vivo virtual histology compared with in vitro histopathology", J Am Coll Cardiol, 47, pp.2405~2412 (2006)
  14. Takano M, "Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation", Am J Cardiol, 99, pp.1033~1038 (2007)
  15. Barlis P, "Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage", Int J Cardiol, 141, pp.151~156 (2010)
  16. Kim BK, "Optical coherence tomography analysis of strut coverage in biolimusand sirolimus-eluting stents: 3-month and 12-month serial follow-up", Int J Cardiol, 168, pp.4617~4623 (2013)
  17. Kim BK, "Randomised comparison of strut coverage between Nobori biolimuseluting and sirolimus-eluting stents: an optical coherence tomography analysis", EuroIntervention, 9, pp.1389~1397 (2014)
  18. Tanigawa J, "The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography", Int J Cardiol, 134, pp.180~188 (2009)
  19. Davlouros PA, "An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9", Int J Cardiol, 157, pp.341~346 (2012)
  20. Hong MK, "Late stent malapposition after drug-eluting stent implantation:an intravascular ultrasound analysis with long-term follow-up", Circulation, 113, pp.414~419 (2006)
  21. Ako J, "Late incomplete stent apposition after sirolimus-eluting stent implantation:a serial intravascular ultrasound analysis", J Am Coll Cardiol, 46, pp.1002~1005 (2005)
  22. Hong YJ, "Relation between poststenting peristent plaque components and late stent malapposition after drug-eluting stent implantation: virtual histology-intravascular ultrasound analysis", Int J Cardiol, 167, pp.1882~1887 (2013)

관련 논문AI추천

Optical Coherence Tomographic Observation of Morphological Features of Neointimal Tissue after Drug-Eluting Stent Implantation고영국, 김병극, 김중선, 신동호, 이승률, 장양수, 최동훈, 홍명기연세대학교의과대학 · Yonsei Medical Journal2014 · 제55권 제4호Relationship between Angiographic Late Loss and 5-Year Clinical Outcome after Drug-Eluting Stent Implantation고영국, 김병극, 김중선, 신동호, 신상훈, 양영준, 장양수, 최동훈, 홍명기연세대학교의과대학 · Yonsei Medical Journal2013 · 제54권 제1호Stent Evaluation with Optical Coherence Tomography이승률, 홍명기연세대학교의과대학 · Yonsei Medical Journal2013 · 제54권 제5호Intravascular imaging analysis of a drug-eluting balloon followed by a bare metal stent compared to a drug-eluting stent for treatment of de novo lesions강시혁, 김선화, 박진주, 연태진, 오일영, 윤창환, 조영석, 채인호, 최동주, 최원석대한내과학회 · The Korean Journal of Internal Medicine2019 · 제34권 제4호Comparison of Sirolimus and Paclitaxel-Eluting Stents for Complex Coronary Lesions: An Intravascular Ultrasound Study김권배, 김윤년, 김인철, 김현태, 김형섭, 남창욱, 박형섭, 윤혁준, 조윤경, 한성욱, 허승호대한내과학회 · The Korean Journal of Internal Medicine2009 · 제24권 제4호Impact of Statin Treatment on Strut Coverage after Drug-Eluting Stent Implantation고영국, 김병극, 김중선, 서용성, 신동호, 장양수, 최동훈, 홍명기연세대학교의과대학 · Yonsei Medical Journal2015 · 제56권 제1호

이 간행물의 다른 논문 (22건)